Endress + Hauser CPS71D-7TP5V pH comb. electrode, Memosens functionality Signal transmission: Digital Diaphragm: Ceramic Reference system: Gel (non acrylamide), Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min … [Read more...] about CPS71D-7TP5V
Endress + Hauser Orbisint Glass electrode CPS sensors
Digital pH sensor Orbisint CPS11 Glass electrode
Redox electrodes CPS12 / CPS12D and CPS13
Digital combined pH/ORP sensor Memosens CPS16D
Digital combined pH/ORP sensor Memosens CPS16E
Analog pH sensor Memosens CPS31 Glass electrode
Digital pH sensor Memosens CPS31D Glass electrode
Analog pH sensor Memosens CPS41 Glass electrode
Digital pH sensor Memosens CPS41D Glass electrode
Digital pH sensor Memosens CPS41E Glass electrode
Digital pH sensor Memosens CPS441D Glass electrode
Digital pH sensor Memosens CPS47D Non-glass electrode
Digital pH sensor Memosens CPS471D non-glass electrode
Digital pH sensor Memosens CPS61E Glass electrode
Digital ORP sensor Memosens CPS62E Glass electrode
Analog pH sensor / electrode Memosens CPS71
Digital pH sensor / electrode Memosens CPS71D
Digital pH sensor / electrode Memosens CPS71E
Analog ORP sensor CPS72
Digital combined pH/ORP sensor Memosens CPS76D
Digital pH sensor Memosens CPS77D Non-glass electrode
Analogue pH sensor CPS91
Digital pH sensor CPS91D
Digital ORP sensor CPS92D
Digital ORP sensor CPS92E
Digital combined pH/ORP Glass sensor Memosens CPS96D
Digital combined pH/ORP Glass sensor Memosens CPS96E
Bio-TechpH glass electrode CPS171D
Digital pH sensor Memosens CPS341D Non-glass electrode
Analog non-glass pH sensor CPS491
Digital chlorine dioxide sensor Memosens CCS50D
CCS51 low-maintenance sensor for free chlorine
Digital optical oxygen sensor for hygienic applications Memosens COS81D Glass electrode
Digital 4-electrode conductivity sensor Memosens CLS82D
Digital sensor for NITRATE OR SAC MEASUREMENT CAS51D
CPS41-3AB2ESC
Endress + Hauser CPS41-3AB2ESC Electrodo combinado de pH Diafragma: Cerámico Referencia: Líquido, conexión para tubo de electrolito Presión máxima: 10 bar Endress Hauser CPS 41 3 Tipo de Electrodo: Punto cero Eo=7,0; con sensor Pt1000 AB Rango, Aplicación: 1-12pH; -15-80oC,1 … [Read more...] about CPS41-3AB2ESC
CPS71-2TP4ESC
Endress + Hauser CPS71-2TP4ESC pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TP4ESC
CPS41-1BB2ESK
Endress + Hauser CPS41-1BB2ESK pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress + Hauser CPS 41 1 Electrode Type: Zero point Eo=7.0 BB Application Range: 0-14pH;0-130oC,1diaph.,steriliz. also replacement for DB type … [Read more...] about CPS41-1BB2ESK
CPS41-1BC4ESS
Endress + Hauser CPS41-1BC4ESS pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 1 Electrode Type: Zero point Eo=7.0 BC Application Range: 0-14pH, 0-130oC,3Diaphr.steril. 4 Shaft Length: 225mm ESS Head: … [Read more...] about CPS41-1BC4ESS
CPS41-3AC2ESK
Endress + Hauser CPS41-3AC2ESK pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 3 Electrode Type: Zero point Eo=7,0; with PT1000 sensor AC Application Range: 1-12pH; -15-80oC, 3 diaphragms 2 Shaft … [Read more...] about CPS41-3AC2ESK
CPS71-2TP5ESA
Endress + Hauser CPS71-2TP5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TP5ESA
CPS41-2BC2ESC
Endress + Hauser CPS41-2BC2ESC pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 2 Electrode Type: Zero point Eo=7.0 + Pt100 BC Application Range: 0-14pH, 0-130oC,3Diaphr.steril. 2 Shaft Length: 120mm … [Read more...] about CPS41-2BC2ESC
CPS71-2TU2ESA
Endress + Hauser CPS71-2TU2ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TU2ESA
CPS41-1AC2ESK
Endress + Hauser CPS41-1AC2ESK pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 1 Electrode Type: Zero point Eo=7.0 AC Application Range: 1-12pH; -15-80oC, 3 diaphragms 2 Shaft Length: 120mm ESK Head: … [Read more...] about CPS41-1AC2ESK
CPS71-1TB6ESA
Endress + Hauser CPS71-1TB6ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 1 Electrode Type: Zero point … [Read more...] about CPS71-1TB6ESA
CPS71-2TP2ESA
Endress + Hauser CPS71-2TP2ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TP2ESA
CPS41-2BC4ESS
Endress + Hauser CPS41-2BC4ESS pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 2 Electrode Type: Zero point Eo=7.0 + Pt100 BC Application Range: 0-14pH, 0-130oC,3Diaphr.steril. 4 Shaft Length: 225mm … [Read more...] about CPS41-2BC4ESS
CPS71-1TB5ESA
Endress + Hauser CPS71-1TB5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 1 Electrode Type: Zero point … [Read more...] about CPS71-1TB5ESA
CPS71-2TB5ESA
Endress + Hauser CPS71-2TB5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TB5ESA
CPS41-2AB4ESA
Endress + Hauser CPS41-2AB4ESA pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 2 Electrode Type: Zero point Eo=7.0 + Pt100 AB Application Range: 1-12pH; -15-80oC,1 diaphragm 4 Shaft Length: 225mm … [Read more...] about CPS41-2AB4ESA
CPS341D-7A1MC
Endress + Hauser CPS341D-7A1MC pH-electrode with pH-sensitive enamel, hygienic design for food and pharma, CIP- and SIP-able, Memosens functionality, signal transmission digital with CYK10 cable, ground diaphragm, reference system Ag/AgCl, integrated temperature … [Read more...] about CPS341D-7A1MC
CPS41-3AB2ESK
Endress + Hauser CPS41-3AB2ESK pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 3 Electrode Type: Zero point Eo=7,0; with PT1000 sensor AB Application Range: 1-12pH; -15-80oC,1 diaphragm 2 Shaft Length: … [Read more...] about CPS41-3AB2ESK
CPS71-3TC2ESA
Endress + Hauser CPS71-3TC2ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TC2ESA
CPS41-2BB2ESK
Endress + Hauser CPS41-2BB2ESK pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 2 Electrode Type: Zero point Eo=7.0 + Pt100 BB Application Range: 0-14pH;0-130oC,1diaph.,steriliz. also replacement for DB … [Read more...] about CPS41-2BB2ESK
CPS71-1TC4ESA
Endress + Hauser CPS71-1TC4ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 1 Electrode Type: Zero point … [Read more...] about CPS71-1TC4ESA
CPS71-3TB5ESA
Endress + Hauser CPS71-3TB5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TB5ESA
CPS41-3AC2ESC
Endress + Hauser CPS41-3AC2ESC pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 3 Electrode Type: Zero point Eo=7,0; with PT1000 sensor AC Application Range: 1-12pH; -15-80oC, 3 diaphragms 2 Shaft Length: … [Read more...] about CPS41-3AC2ESC
CPS71-2TU5ESC
Endress + Hauser CPS71-2TU5ESC pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TU5ESC
CPS41-1BC2ESK
Endress + Hauser CPS41-1BC2ESK pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 1 Electrode Type: Zero point Eo=7.0 BC Application Range: 0-14pH, 0-130oC,3Diaphr.steril. 2 Shaft Length: 120mm ESK Head: … [Read more...] about CPS41-1BC2ESK
CPS71-2TC2ESA
Endress + Hauser CPS71-2TC2ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TC2ESA
CPS491-4ESB2+Z1
Endress + Hauser CPS491-4ESB2+Z1 pH-comb. electrode, ISFET-Technology Diaphragm: open aperture Reference: Gel Temp. sensor: Pt1000 Material: PEEK Working limit: max 10 bar CPS491-1118/0 Endress Hauser CPS 491 4 Shaft Length: 225mm ESB Head: Process Pg13.5; plug TOP68, Ex … [Read more...] about CPS491-4ESB2+Z1
CPS41-1AB2ESC
Endress + Hauser CPS41-1AB2ESC pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 1 Electrode Type: Zero point Eo=7.0 AB Application Range: 1-12pH; -15-80oC,1 diaphragm 2 Shaft Length: 120mm ESC Head: … [Read more...] about CPS41-1AB2ESC
CPS71-2TB6ESA
Endress + Hauser CPS71-2TB6ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TB6ESA
CPS41-3BB4ESA
Endress + Hauser CPS41-3BB4ESA pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 3 Electrode Type: Zero point Eo=7,0; with PT1000 sensor BB Application Range: 0-14pH;0-130oC,1diaph.,steriliz. also replacement … [Read more...] about CPS41-3BB4ESA