• Skip to content
  • Skip to primary sidebar
  • Skip to footer

Bromberg, Staudt & Co. GmbH

  • Home
  • About us
  • Our services
  • Industries
  • Brands
    • Endress+Hauser
  • Contacts
  • EnglishEnglish
    • EspañolEspañol
    • TagalogTagalog
    • 한국어한국어
    • 中文 (中国)中文 (中国)
    • DeutschDeutsch
Home / Endress+Hauser / E+H Analytics / Sensors/Electrodes / CPS12 / CPS13 electrodes

Endress + Hauser Redox ORP electrodes Orbisint CPS12 / CPS12D and CPS13

ENDRESS + HAUSER Redox ORP electrodes Orbisint CPS12 / CPS12D and CPS13 Glass

ORP electrodes Orbisint CPS12 / CPS12D and CPS13 Redox
Memosens functionality
Reference system: Gel

Redox electrodes CPS12 / CPS12D and CPS13 application:

Long-term monitoring and limit monitoring of processes with stable process conditions
– Paper industry
– Plastics chemistry
– Power plants (e.g. flue gas washers)
– Incineration plants
– Food industry
– Breweries
• Water treatment
– Drinking water
– Cooling water
– Well water
With ATEX, FM1 and CSA1 approval for application in hazardous areas

Redox electrodes CPS12 / CPS12D and CPS13 advantages are:

  • - Robust electrode requiring low maintenance thanks to large PTFE ring diaphragm
  • - Application under pressures of up to 16 bar (232 psi)
  • - Long service life due to double junction system of metal lead and thus long electrode poison diffusion path
  • - Various measuring elements for application in oxidising and reducing media
  • - Three lengths: 120, 225 and 360 mm (4.72, 8.86 and 14.17 inches)

Redox electrodes CPS12 / CPS12D and CPS13 measured values:

  • - Redox potential

Available CPS12 / CPS12D and CPS13 measuring range:

  • -1500 ... 1500 mV - Please observe the process operating conditions

CPS71D-7TB61

© E+H Orbisint CPS12D-7TB61

Endress + Hauser CPS71D-7TB61 pH comb. electrode Memosens functionality Signal transmission: Digital Diaphragm: Ceramic Reference system: Gel (non acrylamide), Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min … [Read more...] about CPS71D-7TB61

CPS12-0PA4ESA

© E+H Orbisint CPS12-0PA4ESA

Endress + Hauser CPS12-0PA4ESA Analog ORP sensor / Redox comb. electrode Diaphragm: PTFE Reference system: Gel Application: -1500mV-1500mV, -15...130oC Max. operating pressure: max 16 bar Endress + Hauser CPS12  0 Electrode Type: Basic version  PA Measuring Surface: Platinum  4 … [Read more...] about CPS12-0PA4ESA

CPS12-0PA5ESC

© E+H Orbisint CPS12-0PA5ESC

Endress + Hauser CPS12-0PA5ESC Analog ORP sensor / Redox comb. electrode Diaphragm: PTFE Reference system: Gel Application: -1500mV-1500mV, -15...130oC Max. operating pressure: max 16 bar Endress + Hauser CPS12  0 Electrode Type: Basic version  PA Measuring Surface: Platinum  5 … [Read more...] about CPS12-0PA5ESC

CPS12D-7NA5V

© E+H Orbisint CPS12D-7NA5V

Endress + Hauser CPS12D-7NA5V Digital ORP sensor / Redox comb. electrode Memosens functionality Signal transfer: Digital Diaphragma: PTFE Reference system: Gel Application: -15-135oC Operating pressure: max. 16 bar Endress + Hauser CPS12D  7 Version: Basic version  NA Measuring … [Read more...] about CPS12D-7NA5V

CPS12-0PA4ESC

© E+H Orbisint CPS12-0PA4ESC

Endress + Hauser CPS12-0PA4ESC Analog ORP sensor / Redox comb. electrode Diaphragm: PTFE Reference system: Gel Application: -1500mV-1500mV, -15...130oC Max. operating pressure: max 16 bar Endress + Hauser CPS12  0 Electrode Type: Basic version  PA Measuring Surface: Platinum  4 … [Read more...] about CPS12-0PA4ESC

CPS12D-7NA5G

© E+H Orbisint CPS12D-7NA5G

Endress + Hauser CPS12D-7NA5G Digital ORP sensor / Redox comb. electrode Memosens functionality Signal transfer: Digital Diaphragma: PTFE Reference system: Gel Application: -15-135oC Operating pressure: max. 16 bar Endress + Hauser CPS12D  7 Version: Basic version  NA Measuring … [Read more...] about CPS12D-7NA5G

CPS12-0PA2GSA

© E+H Orbisint CPS12-0PA2GSA

Endress + Hauser CPS12-0PA2GSA Analog ORP sensor / Redox comb. electrode Diaphragm: PTFE Reference system: Gel Application: -1500mV-1500mV, -15...130oC Max. operating pressure: max 16 bar Endress + Hauser CPS12  0 Electrode Type: Basic version  PA Measuring Surface: Platinum  2 … [Read more...] about CPS12-0PA2GSA

CPS12D-7NA5C

© E+H Orbisint CPS12D-7NA5C

Endress + Hauser CPS12D-7NA5C Digital ORP sensor / Redox comb. electrode Memosens functionality Signal transfer: Digital Diaphragma: PTFE Reference system: Gel Application: -15-135oC Operating pressure: max. 16 bar Endress + Hauser CPS12D  7 Version: Basic version  NA Measuring … [Read more...] about CPS12D-7NA5C

  • Page 1
  • Page 2
  • Page 3
  • …
  • Page 7
  • Next Page »

Primary Sidebar

Contact us:




E+H Analytics

  • Orbisint Sensors / Electrodes
    • CPS11 electrodes
    • CPS12 / CPS13 electrodes
  • CPS171D Bio-TechpH electrodes
  • CPS71 electrodes
  • Condumax
    • CLS12
    • CLS13
    • CLS15
    • CLS15D
    • CLS16
    • CLS16D
    • CLS19
    • CLS30
  • Indumax
    • CLS54
  • Liquiline
  • Liquisys
    • CLM223
  • Orbipac sensors
    • CPF81
    • CPF81D
    • CPF82
    • CPF82D

E+H Level measurement

  • Levelflex
  • Liquicap
  • Liquiphant
  • Liquipoint
  • Minicap
  • Micropilot
  • Soliphant

E+H Flow measurement

  • Flowphant
  • Picomag DMA
  • Promag 10
    • Promag 10D
  • Promag 50
  • Promag 53
  • Promag 200
  • Promag300

E+H Pressure measurement

  • Cerabar
  • Ceraphant
  • Deltabar
  • Deltapilot

More products

  • CLM223-IS3105
  • CPF81-LH12B2
  • CPF82-PA31B2
  • DMA20-AAAAA1
  • CLM223-CD0305
  • CPF81-NN22B2
  • 10D65-3CGA1AA0A5AA+M1
  • 10D25-3CGA1AA0A5AA+M1
  • CLS15-B3D2A
  • CLS19-A1A1A
  • CLS15-L3D2A
  • PMC11-AA1U1KBWTJJ
  • CLM223-ID5105
  • CLS16D-3C1PO
  • CLS54-OMV5012
  • PMC11-AA1U1HJWTJA
  • CPF82-PA11B3
  • CPF81-LH32D3
  • CLS54-AVA4012
  • CLS15-B4D3A

Footer

  • Contacts
  • Imprint
  • General Data Protection Regulation (GDPR) – Datenschutz
  • Conditions of Use
  • Copyright
  • Privacy Notice

Search

© 2019 · Bromberg, Staudt & Co.
All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.