Endress + Hauser CPS62E-MA7PTU2+J1 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-MA7PTU2+J1
Endress + Hauser CPS62E Digital ORP sensor Memosens 2.0 - for the chemical and life sciences industries
Endress + Hauser Digital ORP sensor Memosens 2.0 CPS62E for demanding processes and hygienic applications. Its contamination-resistant gel guarantees stable measurement even in flowing media, in low conductivities and at high temperatures.
Digital ORP electrode for hygienic production processes with ion trap for long-term stable reference:
CPS62E measured value
- ORP / Redox
CPS62E application
• Process technology and monitoring of processes with:
- Quickly changing ORP values
- High proportion of electrode poisons such as H2S
• Chemical processes
• Hygienic and sterile applications:
- Fermenters
- Biotechnology
- Life sciences
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
CPS62E advantages
• Sensor resists strong acids and bases and high organic loads.
• Maintains high accuracy even after CIP/SIP or autoclaving.
• Free from animal-based materials and from acrylamide.
• Upside-down mounting option allows for flexible installation.
• Maximum process safety is ensured by non-contact, inductive signal transmission.
• Minimized process downtime and extended sensor lifetime result in reduced operating costs.
CPS62E measuring range
CPS62E process temperature
0 to 140 °C (32 to 284 °F) (140 °C (284 °F) or sterilization only)
CPS62E process pressure
CPS62E storage temperature
0 to 50 °C (32 to 120 °F)
CPS62E-JA7PTU4+J1
Endress + Hauser CPS62E-JA7PTU4+J1 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-JA7PTU4+J1
CPS62E-MA7PTU5
Endress + Hauser CPS62E-MA7PTU5 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-MA7PTU5
CPS62E-IA7PTU4
Endress + Hauser CPS62E-IA7PTU4 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-IA7PTU4
CPS62E-CI7PTU2
Endress + Hauser CPS62E-CI7PTU2 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-CI7PTU2
CPS62E-IA7PTU4+J1
Endress + Hauser CPS62E-IA7PTU4+J1 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-IA7PTU4+J1
CPS62E-JA7PTU5
Endress + Hauser CPS62E-JA7PTU5 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-JA7PTU5
CPS62E-BA7PTU4
Endress + Hauser CPS62E-BA7PTU4 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-BA7PTU4
CPS62E-UR7PTU5
Endress + Hauser CPS62E-UR7PTU5 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-UR7PTU5
CPS62E-CI7PTU5
Endress + Hauser CPS62E-CI7PTU5 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-CI7PTU5
CPS62E-AA7PTU4
Endress + Hauser CPS62E-AA7PTU4 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-AA7PTU4
CPS62E-CB7PTU4
Endress + Hauser CPS62E-CB7PTU4 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-CB7PTU4
CPS62E-AA7PTU5
Endress + Hauser CPS62E-AA7PTU5 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-AA7PTU5
CPS62E-NA7PTU2
Endress + Hauser CPS62E-NA7PTU2 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-NA7PTU2
CPS62E-UA7PTU4
Endress + Hauser CPS62E-UA7PTU4 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-UA7PTU4
CPS62E-GA7PTU4+J1
Endress + Hauser CPS62E-GA7PTU4+J1 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-GA7PTU4+J1
CPS62E-CB7PTU5
Endress + Hauser CPS62E-CB7PTU5 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-CB7PTU5
CPS62E-KA7PTU2
Endress + Hauser CPS62E-KA7PTU2 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-KA7PTU2
CPS62E-BA7PTU5
Endress + Hauser CPS62E-BA7PTU5 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-BA7PTU5
CPS62E-UA7PTU2+J1
Endress + Hauser CPS62E-UA7PTU2+J1 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-UA7PTU2+J1
CPS62E-KA7PTU4
Endress + Hauser CPS62E-KA7PTU4 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-KA7PTU4
CPS62E-IA7PTU2
Endress + Hauser CPS62E-IA7PTU2 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-IA7PTU2
CPS62E-JA7PTU2+J1
Endress + Hauser CPS62E-JA7PTU2+J1 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-JA7PTU2+J1
CPS62E-GA7PTU4
Endress + Hauser CPS62E-GA7PTU4 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-GA7PTU4
CPS62E-CB7PTU2
Endress + Hauser CPS62E-CB7PTU2 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-CB7PTU2
CPS62E-NA7PTU4
Endress + Hauser CPS62E-NA7PTU4 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-NA7PTU4
CPS62E-BA7PTU2
Endress + Hauser CPS62E-BA7PTU2 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology ORP element: … [Read more...] about CPS62E-BA7PTU2
CPS62E-GA7PTU2
Endress + Hauser CPS62E-GA7PTU2 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-GA7PTU2
CPS62E-UR7PTU4
Endress + Hauser CPS62E-UR7PTU4 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-UR7PTU4
CPS62E-AA7PTU2
Endress + Hauser CPS62E-AA7PTU2 ORP comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Upside down mounting. 1 junction. Processes with hygienic requirements such asLife Science and Bio Technology. ORP … [Read more...] about CPS62E-AA7PTU2