Endress + Hauser CPS61E-KA6NTP5 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-KA6NTP5
Endress + Hauser CPS61E Digital pH sensor Memosens 2.0 - glass electrode for food & beverage and bioreactors in biotech industry
Endress + Hauser Digital pH sensor Memosens 2.0 CPS61E for hygienic production processes with ion trap for long-term stable reference. All shaft lengths with temperature sensor. Advanced gel technology. Gel compact electrode with ceramic junction and ion trap.
CPS61E measured value
- pH
CPS61E application
• Biotech and pharma industries
- Bioreactors/fermenters: process control in enzyme production
- Bioreactors/fermenters: control of culture growth
• Food & Beverage
- CIP/SIP applications
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
A pharma certificate of compliance with sensor serial number specified is available.
CPS61E advantages
• The sensor's exceptional accuracy and reproducibility help you to keep the pH value in the optimum range for a maximized product yield.
• A special glass membrane and reference system makes the sensor CIP/SIP and autoclaving resistant (up to 140°C/284°F) offering maximum long-term stability.
• The sensor protects your product quality with its certified biocompatibility according to USP class VI, FDA compliance of wetted parts, VO 1935/2004 compliance, no cytotoxicity, bioreactivity or animal-based materials.
• Streamline maintenance of CPS61E with the Memobase Plus software that automatically stores and documents all relevant sensor and process data.
• Maximum process safety through non-contact, inductive signal transmission
• Reduced operating costs thanks to minimized process downtime and extended sensor lifetime.
CPS61E measuring range
CPS61E process temperature
0 to 100 °C (32 to 212 °F)
Up to 140 °C (284 °F) for sterilization
CPS61E process pressure
CPS61E storage temperature
0 to 50 °C (32 to 120 °F)
CPS61E-GR6NTP2+LC
Endress + Hauser CPS61E-GR6NTP2+LC pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-GR6NTP2+LC
CPS61E-GR6NTP5
Endress + Hauser CPS61E-GR6NTP5 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-GR6NTP5
CPS61E-GR6NTP2
Endress + Hauser CPS61E-GR6NTP2 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-GR6NTP2
CPS61E-UR6NTP5
Endress + Hauser CPS61E-UR6NTP5 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-UR6NTP5
CPS61E-CB6NTP4
Endress + Hauser CPS61E-CB6NTP4 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-CB6NTP4
CPS61E-NA6NTP2+LC
Endress + Hauser CPS61E-NA6NTP2+LC pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-NA6NTP2+LC
CPS61E-GA6MTU5+LC
Endress + Hauser CPS61E-GA6MTU5+LC pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-GA6MTU5+LC
CPS61E-MA6NTP5
Endress + Hauser CPS61E-MA6NTP5 Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science and Bio … [Read more...] about CPS61E-MA6NTP5
CPS61E-AA6NTP2
Endress + Hauser CPS61E-AA6NTP2 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-AA6NTP2
CPS61E-KA6NTP2+LC
Endress + Hauser CPS61E-KA6NTP2+LC pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-KA6NTP2+LC
CPS61E-IA6NTP5
Endress + Hauser CPS61E-IA6NTP5 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-IA6NTP5
CPS61E-GA6NTP5
Endress + Hauser CPS61E-GA6NTP5 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-GA6NTP5
CPS61E-CI6MTU2
Endress + Hauser CPS61E-CI6MTU2 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-CI6MTU2
CPS61E-IA6NTP4
Endress + Hauser CPS61E-IA6NTP4 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-IA6NTP4
CPS61E-NA6NTP5
Endress + Hauser CPS61E-NA6NTP5 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-NA6NTP5
CPS61E-AA6NTP4+LC
Endress + Hauser CPS61E-AA6NTP4+LC pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-AA6NTP4+LC
CPS61E-AA6MTU2
Endress + Hauser CPS61E-AA6MTU2 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-AA6MTU2
CPS61E-MA6MTU2
Endress + Hauser CPS61E-MA6MTU2 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-MA6MTU2
CPS61E-JA6MTU4
Endress + Hauser CPS61E-JA6MTU4 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-JA6MTU4
CPS61E-GR6MTU5
Endress + Hauser CPS61E-GR6MTU5 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-GR6MTU5
CPS61E-AA6MTU4+LC
Endress + Hauser CPS61E-AA6MTU4+LC pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-AA6MTU4+LC
CPS61E-UA6MTU4+LC
Endress + Hauser CPS61E-UA6MTU4+LC pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-UA6MTU4+LC
CPS61E-NA6MTU5+LC
Endress + Hauser CPS61E-NA6MTU5+LC pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-NA6MTU5+LC
CPS61E-MA6NTP4
Endress + Hauser CPS61E-MA6NTP4 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-MA6NTP4
CPS61E-AA6NTP2+LC
Endress + Hauser CPS61E-AA6NTP2+LC pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-AA6NTP2+LC
CPS61E-BA6NTP4+LC
Endress + Hauser CPS61E-BA6NTP4+LC pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-BA6NTP4+LC
CPS61E-CB6NTP4+LC
Endress + Hauser CPS61E-CB6NTP4+LC pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-CB6NTP4+LC
CPS61E-BA6NTP4
Endress + Hauser CPS61E-BA6NTP4 pH comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, Gel (non acrylamide). Pressurized reference or upside down mounting. 1 junction. Processes with hygienic requirements in food, Life Science … [Read more...] about CPS61E-BA6NTP4