• Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Bromberg, Staudt & Co. GmbH

  • Home
  • About us
  • Our services
  • Industries
  • Brands
    • Endress+Hauser
  • Contacts
  • EnglishEnglish
    • EspañolEspañol
    • TagalogTagalog
    • 한국어한국어
    • 中文 (中国)中文 (中国)
    • DeutschDeutsch
Home / Endress+Hauser / E+H Analytics / Sensors/Electrodes / CPS92D

Endress + Hauser CPS92D Digital ORP sensor Orbipore for heavily polluted media in chemical processes, paper or paint production

ENDRESS + HAUSER Digital ORP sensor Orbipore CPS92D

Endress + Hauser Digital ORP sensor Orbipore CPS92D is the digital specialist for fibrous media or media with a high content of suspended solids such as dispersions, precipitation reactions or emulsions.
All shaft lengths - advanced gel technology

CPS92D application

• Chemical processes
• Pulp and paper industry
• Contaminated media and suspended solids
- Dispersions
- Precipitation
- Emulsions
With ATEX, FM, and CSA approval for application in hazardous areas.

CPS92D advantages

• Open aperture for application in heavily soiled media
• Low maintenance and long service life due to stabilized gel filling
• Not affected by fluctuations in pressure and temperature
• Maximum process safety through non-contact inductive signal transmission
• Enables predictive maintenance due to storage of sensor and process-specific data
• Reduced operating costs thanks to minimized process downtime and extended sensor lifetime

CPS92D measured value

  • ORP / Redox

CPS92D measuring range

-1500 mV - +1500 mV

CPS92D process temperature

max. 110°C (230°F)

CPS92D process pressure

max. 13bar (189psi)

CPS92D optional

Temperature sensor NTC30k

CPS92D-7PB4V

© E+H Digital ORP sensor Orbipore CPS92D-7PB4V

Endress + Hauser CPS92D-7PB4V ORP combination electrode Memosens functionality Signal transmission: digital Diaphragm: Open aperture Referenz: Gel Application: Process Temperature: 0-110oC Betriebsgrenze: max. 13 bar CPS92D-10X7/0 Endress Hauser CPS 92D 7 Electrode Type: Basic … [Read more...] about CPS92D-7PB4V

CPS92D-7PB41

© E+H Digital ORP sensor Orbipore CPS92D-7PB41

Endress + Hauser CPS92D-7PB41 ORP combination electrode Memosens functionality Signal transmission: digital Diaphragm: Open aperture Referenz: Gel Application: Process Temperature: 0-110oC Betriebsgrenze: max. 13 bar CPS92D-1014/0 Endress Hauser CPS 92D 7 Electrode Type: Basic … [Read more...] about CPS92D-7PB41

CPS92D-7PB2G

© E+H Digital ORP sensor Orbipore CPS92D-7PB2G

Endress + Hauser CPS92D-7PB2G ORP combination electrode Memosens functionality Signal transmission: digital Diaphragm: Open aperture Referenz: Gel Application: Process Temperature: 0-110oC Betriebsgrenze: max. 13 bar CPS92D-1035/0 Endress Hauser CPS 92D 7 Electrode Type: Basic … [Read more...] about CPS92D-7PB2G

CPS92D-7PB51

© E+H Digital ORP sensor Orbipore CPS92D-7PB51

Endress + Hauser CPS92D-7PB51 ORP combination electrode Memosens functionality Signal transmission: digital Diaphragm: Open aperture Referenz: Gel Application: Process Temperature: 0-110oC Betriebsgrenze: max. 13 bar CPS92D-1020/0 Endress Hauser CPS 92D 7 Electrode Type: Basic … [Read more...] about CPS92D-7PB51

CPS92D-7PB4C

© E+H Digital ORP sensor Orbipore CPS92D-7PB4C

Endress + Hauser CPS92D-7PB4C ORP combination electrode Memosens functionality Signal transmission: digital Diaphragm: Open aperture Referenz: Gel Application: Process Temperature: 0-110oC Betriebsgrenze: max. 13 bar CPS92D-1144/0 Endress Hauser CPS 92D 7 Electrode Type: Basic … [Read more...] about CPS92D-7PB4C

CPS92D-7PB21

© E+H Digital ORP sensor Orbipore CPS92D-7PB21

Endress + Hauser CPS92D-7PB21 ORP combination electrode Memosens functionality Signal transmission: digital Diaphragm: Open aperture Referenz: Gel Application: Process Temperature: 0-110oC Betriebsgrenze: max. 13 bar CPS92D-1009/0 Endress Hauser CPS 92D 7 Electrode Type: Basic … [Read more...] about CPS92D-7PB21

CPS92D-7PB4G

© E+H Digital ORP sensor Orbipore CPS92D-7PB4G

Endress + Hauser CPS92D-7PB4G ORP combination electrode Memosens functionality Signal transmission: digital Diaphragm: Open aperture Referenz: Gel Application: Process Temperature: 0-110oC Betriebsgrenze: max. 13 bar CPS92D-1040/0 Endress Hauser CPS 92D 7 Electrode Type: Basic … [Read more...] about CPS92D-7PB4G

CPS92D-7PB2K

© E+H Digital ORP sensor Orbipore CPS92D-7PB2K

Endress + Hauser CPS92D-7PB2K ORP combination electrode Memosens functionality Signal transmission: digital Diaphragm: Open aperture Referenz: Gel Application: Process Temperature: 0-110oC Betriebsgrenze: max. 13 bar CPS92D-1123/0 Endress Hauser CPS 92D 7 Electrode Type: Basic … [Read more...] about CPS92D-7PB2K

CPS92D-7PB5C

© E+H Digital ORP sensor Orbipore CPS92D-7PB5C

Endress + Hauser CPS92D-7PB5C ORP combination electrode Memosens functionality Signal transmission: digital Diaphragm: Open aperture Referenz: Gel Application: Process Temperature: 0-110oC Betriebsgrenze: max. 13 bar CPS92D-1170/0 Endress Hauser CPS 92D 7 Electrode Type: Basic … [Read more...] about CPS92D-7PB5C

CPS92D-7PB5V

© E+H Digital ORP sensor Orbipore CPS92D-7PB5V

Endress + Hauser CPS92D-7PB5V ORP combination electrode Memosens functionality Signal transmission: digital Diaphragm: Open aperture Referenz: Gel Application: Process Temperature: 0-110oC Betriebsgrenze: max. 13 bar CPS92D-11H3/0 Endress Hauser CPS 92D 7 Electrode Type: Basic … [Read more...] about CPS92D-7PB5V

CPS92D-7PB2V

© E+H Digital ORP sensor Orbipore CPS92D-7PB2V

Endress + Hauser CPS92D-7PB2V ORP combination electrode Memosens functionality Signal transmission: digital Diaphragm: Open aperture Referenz: Gel Application: Process Temperature: 0-110oC Betriebsgrenze: max. 13 bar CPS92D-1102/0 Endress Hauser CPS 92D 7 Electrode Type: Basic … [Read more...] about CPS92D-7PB2V

CPS92D-7PB5K

© E+H Digital ORP sensor Orbipore CPS92D-7PB5K

Endress + Hauser CPS92D-7PB5K ORP combination electrode Memosens functionality Signal transmission: digital Diaphragm: Open aperture Referenz: Gel Application: Process Temperature: 0-110oC Betriebsgrenze: max. 13 bar CPS92D-11E7/0 Endress Hauser CPS 92D 7 Electrode Type: Basic … [Read more...] about CPS92D-7PB5K

CPS92D-7PB2C

© E+H Digital ORP sensor Orbipore CPS92D-7PB2C

Endress + Hauser CPS92D-7PB2C ORP combination electrode Memosens functionality Signal transmission: digital Diaphragm: Open aperture Referenz: Gel Application: Process Temperature: 0-110oC Betriebsgrenze: max. 13 bar CPS92D-1139/0 Endress Hauser CPS92 D 7 Electrode Type: Basic … [Read more...] about CPS92D-7PB2C

Primary Sidebar

Contact us:





    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • NRF81-FD1BE1A1B2BAFICR
    • FMP50-MAAACBAAA1RDJ
    • FMP52-BGAABACAAEK
    • FMP56-C2AABBLAABGDE
    • CLD134-PVA450AA1
    • CLS16D-3G1SG
    • FMP54-I3AABBAED2ABJ
    • FTW23-AA4NWSJ
    • NRF81-FD2BB1A2B1AAENTC
    • FTW23-AA4MX2J
    • FMP52-IBAAAACAAFK
    • FMP50-8CAACDAAA1GDJ
    • NRF81-IA1BE1A1B2BAFICR
    • CLD134-SMV550AA1
    • CLS16D-4E1SG
    • FTW32-B1D2CA2A
    • OUA260-BA1C04C4B3B
    • FMP54-NHAAAAAED2ABJ
    • OUSAF22-D0D2B
    • CM42-OEA110EBE01

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2021 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.