Endress + Hauser COS22-AA3A5E22 Sensor, dissolved oxygen Amperometric design Hygienic design Application: Fermenter, Food, Pharma, Power COS22-14U1/0 Endress Hauser COS 22 AA Approval: non-hazardous area 3 Application: trace process 0,001-2mg/l A5 Diameter; process connection; … [Read more...] about COS22-AA3A5E22
Endress + Hauser Analytics
Endress + Hauser CA72TOC -TOC analyzer
TURBIMAX CUS SENSORS FOR TURBIDITY MEASUREMENT
Process analytical technology pharmaceutical industry
CPS91D-7BO21
Endress + Hauser CPS91D-7BO21 pH-comb. electrode Memosens functionality Signal transmission: Digital Diaphragm: open aperture Reference: Gel Application: Process Temperature sensor integrated Working limit: max 13bar Endress Hauser CPS 91D 7 Version: basic version … [Read more...] about CPS91D-7BO21
CLS16-4G3A1P
Endress + Hauser CLS16-4G3A1P Conductivity 2-electrode sensor Application: hygienic, pure water, ultrapure water FDA, EHEDG sterilizable ATEX II 1G EEx ia IIC T3/T4/T6 / FM Measuring range 0.04-500uS/cm, k=0.1 Process temp. max 120oC (short 150oC) Process pressure max. 12 bar … [Read more...] about CLS16-4G3A1P
COS61D-AAA1A7
Endress + Hauser COS61D-AAA1A7 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration COS61D-18L7/0 Endress Hauser COS 61D AA Approval: Non-hazardous area … [Read more...] about COS61D-AAA1A7
CPS91-3BO4ESK
Endress + Hauser CPS91-3BO4ESK pH-comb. electrode Diaphragm: open aperture Reference: Gel Application: Process Working limit: max 13bar Endress Hauser CPS 91 3 Electrode Type: Zero point Eo=7.0 + Pt1000 BO Application Range: 0-14pH, 0-110oC 4 Shaft Length: 225mm ESK Head: … [Read more...] about CPS91-3BO4ESK
COS51D-CS800
Endress + Hauser COS51D-CS800 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress Hauser COS 51D C Approval: non-hazardous area + EAC marking S Head type: thread NPT 3/4; G1; … [Read more...] about COS51D-CS800
CPS91-2BT6ESK
Endress + Hauser CPS91-2BT6ESK pH-comb. electrode Diaphragm: open aperture Reference: Gel Application: Process Working limit: max 13bar Endress Hauser CPS 91 2 Electrode Type: Zero point Eo=7.0 + Pt100 BT Application Range: 0-14pH; 0-110oC; 13 bar; with ion trap 6 Shaft Length: … [Read more...] about CPS91-2BT6ESK
COS51D-KS910
Endress + Hauser COS51D-KS910 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress Hauser COS 51D K Approval: EAC Ex, 0Ex ia IIC T6 Ga X S Head type: thread NPT 3/4; G1; memosens … [Read more...] about COS51D-KS910
COS41-4S
Endress + Hauser COS41-4S Dissolved oxygen sensor, amperometric 2 electrode cell Application: Water, waste water Measuring range: 0.05...20 mg/l :: Compatibility, Sensor: COS4 Endress + Hauser COS41 4 Cable Length: 15m S Head: Thread G1, NPT3/4; plug TOP68 … [Read more...] about COS41-4S
CPS91-2BT5ESK
Endress + Hauser CPS91-2BT5ESK pH-comb. electrode Diaphragm: open aperture Reference: Gel Application: Process Working limit: max 13bar Endress Hauser CPS 91 2 Electrode Type: Zero point Eo=7.0 + Pt100 BT Application Range: 0-14pH; 0-110oC; 13 bar; with ion trap 5 Shaft Length: … [Read more...] about CPS91-2BT5ESK
CLS16-4G1A1R
Endress + Hauser CLS16-4G1A1R Conductivity 2-electrode sensor Application: hygienic, pure water, ultrapure water FDA, EHEDG sterilizable ATEX II 1G EEx ia IIC T3/T4/T6 / FM Measuring range 0.04-500uS/cm, k=0.1 Process temp. max 120oC (short 150oC) Process pressure max. 12 bar … [Read more...] about CLS16-4G1A1R
COS22-AA1A2B52
Endress + Hauser COS22-AA1A2B52 Sensor, dissolved oxygen Amperometric design Hygienic design Application: Fermenter, Food, Pharma, Power COS22-1098/0 Endress Hauser COS 22 AA Approval: non-hazardous area 1 Application: Standard 0,01-20mg/l A2 Diameter; process connection; … [Read more...] about COS22-AA1A2B52
CLD132-SCS130AA1
Endress + Hauser CLD132-SCS130AA1 Conductivity measuring system Application: hygienic, food CIP control, phase separation Housing: stainless steel, IP67 Alarm output: relay Display: 2-line, 6 languages Sensor: inductive, 0.1-2000mS/cm Process temp. max 125oC (short 140oC) Endress … [Read more...] about CLD132-SCS130AA1
COS61-A2S0
Endress + Hauser COS61-A2S0 Dissolved oxygen sensor, optical Application: Water, Wastewater Digital signal Measuring range: 0,0-20 mg/l Automatic sensorcheck Compatibility, Sensor: COS31, (digital) Endress Hauser COS 61 A Approval: Non-hazardous area 2 Cable Length: 15 m … [Read more...] about COS61-A2S0
CPS91D-7BT5G
Endress + Hauser CPS91D-7BT5G pH-comb. electrode Memosens functionality Signal transmission: Digital Diaphragm: open aperture Reference: Gel Application: Process Temperature sensor integrated Working limit: max 13bar Endress Hauser CPS 91D 7 Version: basic version … [Read more...] about CPS91D-7BT5G
COS61D-GRA1A3
Endress + Hauser COS61D-GRA1A3 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration Endress Hauser COS 61D GR Approval: non-hazardous area + EAC marking … [Read more...] about COS61D-GRA1A3
CLS15-B4D1A
Endress + Hauser CLS15-B4D1A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 B Measuring Range; Cell Constant: 0.1-200uS/cm; k=0.1 … [Read more...] about CLS15-B4D1A
COS61D-GRA1B2
Endress + Hauser COS61D-GRA1B2 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration Endress Hauser COS 61D GR Approval: non-hazardous area + EAC marking … [Read more...] about COS61D-GRA1B2
CLS21-C2A4A
Endress + Hauser CLS21-C2A4A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-C2A4A
CPS91-2BO6ESK
Endress + Hauser CPS91-2BO6ESK pH-comb. electrode Diaphragm: open aperture Reference: Gel Application: Process Working limit: max 13bar Endress Hauser CPS 91 2 Electrode Type: Zero point Eo=7.0 + Pt100 BO Application Range: 0-14pH, 0-110oC 6 Shaft Length: 425mm ESK Head: … [Read more...] about CPS91-2BO6ESK
COS22-AA1A5B52
Endress + Hauser COS22-AA1A5B52 Sensor, dissolved oxygen Amperometric design Hygienic design Application: Fermenter, Food, Pharma, Power COS22-14X8/0 Endress Hauser COS 22 AA Approval: non-hazardous area 1 Application: Standard 0,01-20mg/l A5 Diameter; process connection; … [Read more...] about COS22-AA1A5B52
CLD132-XCS150AA1
Endress + Hauser CLD132-XCS150AA1 Conductivity measuring system Application: hygienic, food CIP control, phase separation Housing: stainless steel, IP67 Alarm output: relay Display: 2-line, 6 languages Sensor: inductive, 0.1-2000mS/cm Process temp. max 125oC (short 140oC) Endress … [Read more...] about CLD132-XCS150AA1
CPS91-3BT4ESK
Endress + Hauser CPS91-3BT4ESK pH-comb. electrode Diaphragm: open aperture Reference: Gel Application: Process Working limit: max 13bar Endress Hauser CPS 91 3 Electrode Type: Zero point Eo=7.0 + Pt1000 BT Application Range: 0-14pH; 0-110oC; 13 bar; with ion trap 4 Shaft … [Read more...] about CPS91-3BT4ESK
CLD132-SSMS30AA1
Endress + Hauser CLD132-SSMS30AA1 Conductivity measuring system Application: hygienic, food CIP control, phase separation Housing: stainless steel, IP67 Alarm output: relay Display: 2-line, 6 languages Sensor: inductive, 0.1-2000mS/cm Process temp. max 125oC (short 140oC) Endress … [Read more...] about CLD132-SSMS30AA1
COS61-A0F0
Endress + Hauser COS61-A0F0 Dissolved oxygen sensor, optical Application: Water, Wastewater Digital signal Measuring range: 0,0-20 mg/l Automatic sensorcheck Compatibility, Sensor: COS31, (digital) Endress Hauser COS 61 A Approval: Non-hazardous area 0 Cable Length: 1.5m … [Read more...] about COS61-A0F0
CLD18-BMOP
Endress + Hauser CLD18-BMOP Measuring system conductivity, inductive compact system Basic model Food industry, CIP control, phase separation economical attractive ::Extrusion-coat sensor ::FDA compliant material ::Remote configuration CLD18-13D5/0 Endress Hauser CLD 18 … [Read more...] about CLD18-BMOP
CLM223-IS0405
Endress + Hauser CLM223-IS0405 Transmitter, conductivity Panel mounting: 96x96mm, front IP54 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CLM 223 IS Sensor Input; Software: Inductive sensor; plus package 0 Power Supply: 230VAC … [Read more...] about CLM223-IS0405
CLD18-CMQK
Endress + Hauser CLD18-CMQK Measuring system conductivity, inductive compact system Basic model Food industry, CIP control, phase separation economical attractive ::Extrusion-coat sensor ::FDA compliant material ::Remote configuration CLD18-1M87/0 Endress Hauser CLD 18 … [Read more...] about CLD18-CMQK
CPS91D-7BO5G
Endress + Hauser CPS91D-7BO5G pH-comb. electrode Memosens functionality Signal transmission: Digital Diaphragm: open aperture Reference: Gel Application: Process. Temperature sensor integrated Working limit: max 13bar Endress Hauser CPS 91D 7 Version: basic version … [Read more...] about CPS91D-7BO5G
CPS91-3BO6ESC
Endress + Hauser CPS91-3BO6ESC pH-comb. electrode Diaphragm: open aperture Reference: Gel Application: Process Working limit: max 13bar Endress Hauser CPS 91 3 Electrode Type: Zero point Eo=7.0 + Pt1000 BO Application Range: 0-14pH, 0-110oC 6 Shaft Length: 425mm ESC Head: … [Read more...] about CPS91-3BO6ESC