Endress + Hauser CLS16-4D1A1R Conductivity 2-electrode sensor Application: hygienic, pure water, ultrapure water FDA, EHEDG sterilizable ATEX II 1G EEx ia IIC T3/T4/T6 / FM Measuring range 0.04-500uS/cm, k=0.1 Process temp. max 120oC (short 150oC) Process pressure max. 12 bar … [Read more...] about CLS16-4D1A1R
Endress + Hauser Analytics
Endress + Hauser CA72TOC -TOC analyzer
TURBIMAX CUS SENSORS FOR TURBIDITY MEASUREMENT
Process analytical technology pharmaceutical industry
CPS91-1BO5ESK
Endress + Hauser CPS91-1BO5ESK pH-comb. electrode Diaphragm: open aperture Reference: Gel Application: Process Working limit: max 13bar Endress Hauser CPS 91 1 Electrode Type: Zero point Eo=7.0 BO Application Range: 0-14pH, 0-110oC 5 Shaft Length: 360mm ESK Head: Process … [Read more...] about CPS91-1BO5ESK
CLS15-L1M3A
Endress + Hauser CLS15-L1M3A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 L Measuring Range; Cell Constant: PWIS free for k=0,1 … [Read more...] about CLS15-L1M3A
COS41-4F
Endress + Hauser COS41-4F Dissolved oxygen sensor, amperometric 2 electrode cell Application: Water, waste water Measuring range: 0.05...20 mg/l :: Compatibility, Sensor: COS4 Endress Hauser COS 41 4 Cable Length: 15m F Head: Thread G1, NPT3/4; fixed cable … [Read more...] about COS41-4F
COS51D-KS800
Endress + Hauser COS51D-KS800 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress Hauser COS 51D K Approval: EAC Ex, 0Ex ia IIC T6 Ga X S Head type: thread NPT 3/4; G1; memosens … [Read more...] about COS51D-KS800
CLD18-CLQP
Endress + Hauser CLD18-CLQP Inductive conductivity measuring system compact system Basic model Food industry, CIP control, phase separation economical attractive ::Extrusion-coat sensor ::FDA compliant material ::Remote configuration CLD18-1E55/0 Endress Hauser CLD 18 … [Read more...] about CLD18-CLQP
COS61-A2F0
Endress + Hauser COS61-A2F0 Dissolved oxygen sensor, optical Application: Water, Wastewater Digital signal Measuring range: 0,0-20 mg/l Automatic sensorcheck Compatibility, Sensor: COS31, (digital) Endress Hauser COS 61 A Approval: Non-hazardous area 2 Cable Length: 15 m … [Read more...] about COS61-A2F0
COS22-AA1A4B52
Endress + Hauser COS22-AA1A4B52 Sensor, dissolved oxygen Amperometric design Hygienic design Application: Fermenter, Food, Pharma, Power COS22-1218/0 Endress Hauser COS 22 AA Approval: non-hazardous area 1 Application: Standard 0,01-20mg/l A4 Diameter; process connection; … [Read more...] about COS22-AA1A4B52
CLD18-AMOK
Endress + Hauser CLD18-AMOK Measuring system conductivity, inductive compact system Basic model Food industry, CIP control, phase separation economical attractive ::Extrusion-coat sensor ::FDA compliant material ::Remote configuration CLD18-1035/0 Endress Hauser CLD 18 … [Read more...] about CLD18-AMOK
CPS91-3BT2ESK
Endress + Hauser CPS91-3BT2ESK pH-comb. electrode Diaphragm: open aperture Reference: Gel Application: Process Working limit: max 13bar Endress Hauser CPS 91 3 Electrode Type: Zero point Eo=7.0 + Pt1000 BT Application Range: 0-14pH; 0-110oC; 13 bar; with ion trap 2 Shaft … [Read more...] about CPS91-3BT2ESK
COS41-2F
Endress + Hauser COS41-2F Dissolved oxygen sensor, amperometric 2 electrode cell Application: Water, waste water Measuring range: 0.05...20 mg/l :: Compatibility, Sensor: COS4 Endress Hauser COS 41 2 Cable Length: 7m F Head: Thread G1, NPT3/4; fixed cable … [Read more...] about COS41-2F
COS22-AA3A5E52
Endress + Hauser COS22-AA3A5E52 Sensor, dissolved oxygen Amperometric design Hygienic design Application: Fermenter, Food, Pharma, Power COS22-10J0/0 Endress Hauser COS 22 AA Approval: non-hazardous area 3 Application: trace process 0,001-2mg/l A5 Diameter; process connection; … [Read more...] about COS22-AA3A5E52
COS22-AA1A6B52+HA
Endress + Hauser COS22-AA1A6B52+HA Sensor, dissolved oxygen Amperometric design Hygienic design Application: Fermenter, Food, Pharma, Power COS22-15D2/0 Endress Hauser COS 22 AA Approval: non-hazardous area 1 Application: Standard 0,01-20mg/l A6 Diameter; process connection; … [Read more...] about COS22-AA1A6B52+HA
COS22-AA3A5B52+HA
Endress + Hauser COS22-AA3A5B52+HA Sensor, dissolved oxygen Amperometric design Hygienic design Application: Fermenter, Food, Pharma, Power COS22-15C7/0 Endress Hauser COS 22 AA Approval: non-hazardous area 3 Application: trace process 0,001-2mg/l A5 Diameter; process … [Read more...] about COS22-AA3A5B52+HA
CLD132-PVA110AA1
Endress + Hauser CLD132-PVA110AA1 Conductivity measuring system Application: hygienic, food CIP control, phase separation Housing: stainless steel, IP67 Alarm output: relay Display: 2-line, 6 languages Sensor: inductive, 0.1-2000mS/cm Process temp. max 125oC (short 140oC) Endress … [Read more...] about CLD132-PVA110AA1
COS61-A1F0
Endress + Hauser COS61-A1F0 Dissolved oxygen sensor, optical Application: Water, Wastewater Digital signal Measuring range: 0,0-20 mg/l Automatic sensorcheck Compatibility, Sensor: COS31, (digital) Endress Hauser COS 61 A Approval: Non-hazardous area 1 Cable Length: 7m F Head: … [Read more...] about COS61-A1F0
COS22-AA3A5E22
Endress + Hauser COS22-AA3A5E22 Sensor, dissolved oxygen Amperometric design Hygienic design Application: Fermenter, Food, Pharma, Power COS22-14U1/0 Endress Hauser COS 22 AA Approval: non-hazardous area 3 Application: trace process 0,001-2mg/l A5 Diameter; process connection; … [Read more...] about COS22-AA3A5E22
CPS91D-7BO21
Endress + Hauser CPS91D-7BO21 pH-comb. electrode Memosens functionality Signal transmission: Digital Diaphragm: open aperture Reference: Gel Application: Process Temperature sensor integrated Working limit: max 13bar Endress Hauser CPS 91D 7 Version: basic version … [Read more...] about CPS91D-7BO21
CLS16-4G3A1P
Endress + Hauser CLS16-4G3A1P Conductivity 2-electrode sensor Application: hygienic, pure water, ultrapure water FDA, EHEDG sterilizable ATEX II 1G EEx ia IIC T3/T4/T6 / FM Measuring range 0.04-500uS/cm, k=0.1 Process temp. max 120oC (short 150oC) Process pressure max. 12 bar … [Read more...] about CLS16-4G3A1P
COS61D-AAA1A7
Endress + Hauser COS61D-AAA1A7 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration COS61D-18L7/0 Endress Hauser COS 61D AA Approval: Non-hazardous area … [Read more...] about COS61D-AAA1A7
CPS91-3BO4ESK
Endress + Hauser CPS91-3BO4ESK pH-comb. electrode Diaphragm: open aperture Reference: Gel Application: Process Working limit: max 13bar Endress Hauser CPS 91 3 Electrode Type: Zero point Eo=7.0 + Pt1000 BO Application Range: 0-14pH, 0-110oC 4 Shaft Length: 225mm ESK Head: … [Read more...] about CPS91-3BO4ESK
COS51D-CS800
Endress + Hauser COS51D-CS800 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress Hauser COS 51D C Approval: non-hazardous area + EAC marking S Head type: thread NPT 3/4; G1; … [Read more...] about COS51D-CS800
CPS91-2BT6ESK
Endress + Hauser CPS91-2BT6ESK pH-comb. electrode Diaphragm: open aperture Reference: Gel Application: Process Working limit: max 13bar Endress Hauser CPS 91 2 Electrode Type: Zero point Eo=7.0 + Pt100 BT Application Range: 0-14pH; 0-110oC; 13 bar; with ion trap 6 Shaft Length: … [Read more...] about CPS91-2BT6ESK
COS51D-KS910
Endress + Hauser COS51D-KS910 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress Hauser COS 51D K Approval: EAC Ex, 0Ex ia IIC T6 Ga X S Head type: thread NPT 3/4; G1; memosens … [Read more...] about COS51D-KS910
COS41-4S
Endress + Hauser COS41-4S Dissolved oxygen sensor, amperometric 2 electrode cell Application: Water, waste water Measuring range: 0.05...20 mg/l :: Compatibility, Sensor: COS4 Endress + Hauser COS41 4 Cable Length: 15m S Head: Thread G1, NPT3/4; plug TOP68 … [Read more...] about COS41-4S
CPS91-2BT5ESK
Endress + Hauser CPS91-2BT5ESK pH-comb. electrode Diaphragm: open aperture Reference: Gel Application: Process Working limit: max 13bar Endress Hauser CPS 91 2 Electrode Type: Zero point Eo=7.0 + Pt100 BT Application Range: 0-14pH; 0-110oC; 13 bar; with ion trap 5 Shaft Length: … [Read more...] about CPS91-2BT5ESK
CLS16-4G1A1R
Endress + Hauser CLS16-4G1A1R Conductivity 2-electrode sensor Application: hygienic, pure water, ultrapure water FDA, EHEDG sterilizable ATEX II 1G EEx ia IIC T3/T4/T6 / FM Measuring range 0.04-500uS/cm, k=0.1 Process temp. max 120oC (short 150oC) Process pressure max. 12 bar … [Read more...] about CLS16-4G1A1R
COS22-AA1A2B52
Endress + Hauser COS22-AA1A2B52 Sensor, dissolved oxygen Amperometric design Hygienic design Application: Fermenter, Food, Pharma, Power COS22-1098/0 Endress Hauser COS 22 AA Approval: non-hazardous area 1 Application: Standard 0,01-20mg/l A2 Diameter; process connection; … [Read more...] about COS22-AA1A2B52
CLD132-SCS130AA1
Endress + Hauser CLD132-SCS130AA1 Conductivity measuring system Application: hygienic, food CIP control, phase separation Housing: stainless steel, IP67 Alarm output: relay Display: 2-line, 6 languages Sensor: inductive, 0.1-2000mS/cm Process temp. max 125oC (short 140oC) Endress … [Read more...] about CLD132-SCS130AA1
COS61-A2S0
Endress + Hauser COS61-A2S0 Dissolved oxygen sensor, optical Application: Water, Wastewater Digital signal Measuring range: 0,0-20 mg/l Automatic sensorcheck Compatibility, Sensor: COS31, (digital) Endress Hauser COS 61 A Approval: Non-hazardous area 2 Cable Length: 15 m … [Read more...] about COS61-A2S0