• Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Bromberg, Staudt & Co. GmbH

  • Home
  • About us
  • Our services
  • Industries
  • Brands
    • Endress+Hauser
  • Contacts
  • EnglishEnglish
    • EspañolEspañol
    • TagalogTagalog
    • 한국어한국어
    • 中文 (中国)中文 (中国)
    • DeutschDeutsch
Home / Endress+Hauser / E+H System products / RMC621

Endress + Hauser RMC621 Flow and energy manager - computer for gases, liquids and steam

ENDRESS + HAUSER RMC621 Flow and energy computer

Endress + Hauser RMC621 flow and energy manager RMC621 calculates standard volume as well as mass and energy flows of natural and technical gases, fluids and steam from flow, pressure,
Predecessors:
• DXF351
• ZL6171
• ZL6351
• ZL6121

Endress + Hauser RMC621 Flow and energy manager measuring principle:

• mass/heat quantity
• heat quantity difference
• for gases: standard volume, heating value, mass

Endress + Hauser RMC621 Flow and energy manager measuring range:

Measured variables: Current, PFM, pulse, temperature
Current
• 0/4 to 20 mA +10% overrange
• Maximum input current 150 mA
• Input impedance < 10 Ω
• Signal attenuation low-pass filter 1st order, filter constants 0 to 99 s configurable
• Fault recognition 3.6 mA and 21 mA limit as per NAMUR NE43

PFM
• Frequency range when using an input on the mainboard (Slot A): 0.25 Hz to 12.5 kHz
• Frequency range when using an input on an extension board (Slot B, C, D): 0.01 Hz to 12.5 kHz
• Signal level 2 to 7 mA low; 13 to 19 mA high
• Measurement method: period length/frequency measurement

Pulse
• Frequency range when using an input on the mainboard (Slot A): 0.25 Hz to 12.5 kHz
• Frequency range when using an input on an extension board (Slot B, C, D): 0.01 Hz to 12.5 kHz
• Signal level 2 to 7 mA low; 13 to 19 mA high with approximately 1.3 kΩ dropping resistor at 24 V voltage level

Temperature Resistance thermometer (RTD) according to ITS 90:
Designation Measuring range
Pt100 –200 to 800 °C (–328 to 1 472 °F)
Pt500 –200 to 250 °C (–328 to 482 °F)
Pt1000 –200 to 250 °C (–328 to 482 °F)
• Type of connection: 3- or 4-wire system
• Measuring current 500 µA

Endress + Hauser RMC621 Flow and energy manager application:

• Energy management
• Chemical industry
• Heating and air conditioning
• Pharmaceutical industry
• Food and beverage
• Plant and panel manufacture
• Oil + petrochemicals

Endress + Hauser RMC621 Flow and energy manager advantages:

• Calculation of the following applications:
• Suitable for applications with gas, liquid, steam and water
• Simultaneous calculation of up to 3 measuring applications, even if different fluids are used
• Very precise process calculations (density, enthalpy, compressibility) on the basis of equations and/or storable tables with material data
• Calculation standards: IAPWS-IF 97, SGERG88, AGA8, real gas equations (SRK, RK), ISO 5167, tables
• Can be used with all common flow measuring systems (vortex, turbine, MID, orifice plate, differential pressure, etc.)
• Compensation input for density signal
• Logbook function for error messages and parameter changes with date and time

Endress + Hauser RMC621 Flow and energy manager input signal:

2...8x PFM
2...8x I
2...8x Impulse (aktiv)
2...6x RTD
2...8x Impulse (passiv)

Endress + Hauser RMC621 Flow and energy manager output signal:

3...9x transmitter power supply

RMC621-F11AAA1EA1

© E+H Energy Manager RMC621-F11AAA1EA1

Endress + Hauser RMC621-F11AAA1EA1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-F11AAA1EA1

RMC621-F31AAA1EA1

© E+H Energy Manager RMC621-F31AAA1EA1

Endress + Hauser RMC621-F31AAA1EA1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-F31AAA1EA1

RMC621-B41AAA1EC1

© E+H Energy Manager RMC621-B41AAA1EC1

Endress + Hauser RMC621-B41AAA1EC1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-B41AAA1EC1

RMC621-F31DDD1EA1

© E+H Energy Manager RMC621-F31DDD1EA1

Endress + Hauser RMC621-F31DDD1EA1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-F31DDD1EA1

RMC621-A41AAA1EC1

© E+H Energy Manager RMC621-A41AAA1EC1

Endress + Hauser RMC621-A41AAA1EC1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-A41AAA1EC1

RMC621-F41AAA1BC1

© E+H Energy Manager RMC621-F41AAA1BC1

Endress + Hauser RMC621-F41AAA1BC1 Medium: gas, liquid, steam, water Diff. pressure calculation DIN5167 Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-F41AAA1BC1

RMC621-B21AAA1EA1

© E+H Energy Manager RMC621-B21AAA1EA1

Endress + Hauser RMC621-B21AAA1EA1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-B21AAA1EA1

RMC621-B41DDD1BC1

© E+H Energy Manager RMC621-B41DDD1BC1

Endress + Hauser RMC621-B41DDD1BC1 Medium: gas, liquid, steam, water Diff. pressure calculation DIN5167 Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-B41DDD1BC1

RMC621-F21AAA1EA1

© E+H Energy Manager RMC621-F21AAA1EA1

Endress + Hauser RMC621-F21AAA1EA1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-F21AAA1EA1

RMC621-U31AAA1EA1

© E+H Energy Manager RMC621-U31AAA1EA1

Endress + Hauser RMC621-U31AAA1EA1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-U31AAA1EA1

RMC621-D11AAA1EA1

© E+H Energy Manager RMC621-D11AAA1EA1

Endress + Hauser RMC621-D11AAA1EA1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-D11AAA1EA1

RMC621-F31AAA1BA1

© E+H Energy Manager RMC621-F31AAA1BA1

Endress + Hauser RMC621-F31AAA1BA1 Medium: gas, liquid, steam, water Diff. pressure calculation DIN5167 Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-F31AAA1BA1

RMC621-C21AAA1EA1

© E+H Energy Manager RMC621-C21AAA1EA1

Endress + Hauser RMC621-C21AAA1EA1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-C21AAA1EA1

RMC621-C21AAA1BA1

© E+H Energy Manager RMC621-C21AAA1BA1

Endress + Hauser RMC621-C21AAA1BA1 Medium: gas, liquid, steam, water Diff. pressure calculation DIN5167 Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-C21AAA1BA1

RMC621-U11AAA1EA1

© E+H Energy Manager RMC621-U11AAA1EA1

Endress + Hauser RMC621-U11AAA1EA1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-U11AAA1EA1

RMC621-D21AAA1BA1

© E+H Energy Manager RMC621-D21AAA1BA1

Endress + Hauser RMC621-D21AAA1BA1 Medium: gas, liquid, steam, water Diff. pressure calculation DIN5167 Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-D21AAA1BA1

RMC621-A11AAA1BA1

© E+H Computador de energía RMC621-A11AAA1BA1

Endress + Hauser RMC621-A11AAA1BA1 Medium: gas, liquid, steam, water Diff. pressure calculation DIN5167 Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-A11AAA1BA1

RMC621-B11AAA1BA1

© E+H Energy Manager RMC621-B11AAA1BA1

Endress + Hauser RMC621-B11AAA1BA1 Medium: gas, liquid, steam, water Diff. pressure calculation DIN5167 Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-B11AAA1BA1

RMC621-A21AAA1EA1

© E+H Energy Manager RMC621-A21AAA1EA1

Endress + Hauser RMC621-A21AAA1EA1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-A21AAA1EA1

RMC621-B41AAA1BC1

© E+H Energy Manager RMC621-B41AAA1BC1

Endress + Hauser RMC621-B41AAA1BC1 Medium: gas, liquid, steam, water Diff. pressure calculation DIN5167 Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-B41AAA1BC1

RMC621-F41AAA1EC1

© E+H Energy Manager RMC621-F41AAA1EC1

Endress + Hauser RMC621-F41AAA1EC1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-F41AAA1EC1

RMC621-U31AAA1BA1

© E+H Energy Manager RMC621-U31AAA1BA1

Endress + Hauser RMC621-U31AAA1BA1 Medium: gas, liquid, steam, water Diff. pressure calculation DIN5167 Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-U31AAA1BA1

RMC621-D11AAA1BA1

© E+H Energy Manager RMC621-D11AAA1BA1

Endress + Hauser RMC621-D11AAA1BA1 Medium: gas, liquid, steam, water Diff. pressure calculation DIN5167 Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-D11AAA1BA1

RMC621-A41AAA1BC1

© E+H Energy Manager RMC621-A41AAA1BC1

Endress + Hauser RMC621-A41AAA1BC1 Medium: gas, liquid, steam, water Diff. pressure calculation DIN5167 Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-A41AAA1BC1

RMC621-F41EEE1EC1

© E+H Energy Manager RMC621-F41EEE1EC1

Endress + Hauser RMC621-F41EEE1EC1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-F41EEE1EC1

RMC621-F31AAA1EA1

© E+H Energy Manager RMC621-F31AAA1EA1

Endress + Hauser RMC621-F31AAA1EA1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-F31AAA1EA1

RMC621-A11AAA1EA1

© E+H Energy Manager RMC621-A11AAA1EA1

Endress + Hauser RMC621-A11AAA1EA1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-A11AAA1EA1

RMC621-U21AAA1EA1

© E+H Energy Manager RMC621-U21AAA1EA1

Endress + Hauser RMC621-U21AAA1EA1 Medium: gas, liquid, steam, water. Diff. pressure calculation DIN5167. Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-U21AAA1EA1

RMC621-U41AAA1BC1

© E+H Energy Manager RMC621-U41AAA1BC1

Endress + Hauser RMC621-U41AAA1BC1 Medium: gas, liquid, steam, water Diff. pressure calculation DIN5167 Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-U41AAA1BC1

RMC621-C11AAA1BA1

© E+H Energy Manager RMC621-C11AAA1BA1

Endress + Hauser RMC621-C11AAA1BA1 Medium: gas, liquid, steam, water Diff. pressure calculation DIN5167 Basic functions Slot A + E: 1x RS232 + 1x RS485. 3x LPS = loop power supply. Input A: 2x 0/4-20mA/PFM/pulse. Output A: 1x relay. Input E: 2x Pt100/500/1000. Output E: 2x … [Read more...] about RMC621-C11AAA1BA1

  • Go to page 1
  • Go to page 2
  • Go to Next Page »

Primary Sidebar

Contact us:





    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • CM444R-CDM4BA1FK6
    • CPS16E-KA7ATA2
    • CPS16E-NA7ATA4
    • CPS16E-GR7BTA4
    • CM444R-CAM4BA5FA1
    • CPS16E-JA7ATA4
    • CPS92E-BA7PHH5+Z1
    • CPS16E-CB7ATA4
    • CPS92E-UA7PHH4+Z1
    • CPS41E-NA7ASC5
    • 10D25-3TGA1AA0A0BA
    • CPS92E-UA7PHH2+Z1
    • CPS41E-JA7BSB4
    • 10D25-6VGAEAA0A0BA
    • CPS92E-MA7PHH5
    • CPS92E-IA7PHH2
    • CPS41E-IA7BSB4
    • 10D25-7LGA1AA0A0BA
    • CPS92E-MA7PHH4
    • CPS41E-BA7ASB4

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2023 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.