discontinued without direct replacement
Endress + Hauser RMC621-F41EEE1EC1
Medium: gas, liquid, steam, water.
Diff. pressure calculation DIN5167.
Basic functions Slot A + E:
1x RS232 + 1x RS485.
3x LPS = loop power supply.
Input A: 2x 0/4-20mA/PFM/pulse.
Output A: 1x relay.
Input E: 2x Pt100/500/1000.
Output E: 2x 0/4-20mA/pulse.
Calculation formula acc. IAPWS-IF97.
Real gas formula, NX19, OIML R117.
Approval: UL listed, CSA GP.
:: max. 3x Application
:: max. 4 Media / instrument
:: intrinsically safe inputs.
Endress Hauser RMC 621
F Approval: IECEx (Ex ia) IIC
4 Operation: Panel 144x72mm, 2x RS485
1 Power Supply: 90-250VAC
E Slot B: Input Ex-i, 2x Pt100/500/1000 output 2x 0/4-20mA/pulse 2x digital, 2x relay SPST
E Slot C: Input Ex-i 2x Pt100/500/1000 output 2x 0/4-20mA/pulse 2x digital, 2x relay SPST
E Slot D: Input Ex-i, 2x Pt100/500/1000 output 2x 0/4-20mA/pulse 2x digital, 2x relay SPST
1 Software: Basic version
E Operation Language: Spanish
C Communication: 1x RS232 + PROFINET device external
1 Additional Option: Basic version