Endress + Hauser CLS50-H1C3 Conductivity, inductive sensor Application: chemistry, waste water Measurement conductivity/concentration Highly resistant sensor material Quality certificate Endress Hauser CLS 50 H Approval: NEPSI Ex iA IIC T4/T6 1 Process Connection: Thread G 3/4 … [Read more...] about CLS50-H1C3
Endress + Hauser Analytics
Endress + Hauser CA72TOC -TOC analyzer
TURBIMAX CUS SENSORS FOR TURBIDITY MEASUREMENT
Process analytical technology pharmaceutical industry
CLS54-ASMS312
Endress + Hauser CLS54-ASMS312 Conductivity, inductive sensor Application: hygienic Food, pharma CIP control, phase separation Process temp. max.120oC (short 150oC) Process pressure max.12 bar (20oC) Sensor material: PEEK Quality certificate Endress Hauser CLS 54 A Approval … [Read more...] about CLS54-ASMS312
COM223-DS1515
Endress + Hauser COM223-DS1515 Transmitter, dissolved oxygen DO Panel mounting: 96x96mm, front IP54 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser COM 223 DS Sensor Input; Software: COS41 (COS4/4HD); plus package 1 Power Supply: 115VAC … [Read more...] about COM223-DS1515
CM42-IAA602EBD00
Endress + Hauser CM42-IAA602EBD00 Transmitter liquid analysis Multiparameter, loop-powered Worldwide approvals, hazardous areas developed according to IEC 61508, pH/ORP, conductivity,oxygen (DO) digital sensors, Memosens protocol or analog sensors Field housing+panel mounting … [Read more...] about CM42-IAA602EBD00
CLS16D-3G1UG
Endress + Hauser CLS16D-3G1UG Conductivity, 2-electrode sensor Memosens functionality hygienic design, EHEDG Life Science, Water (Utilities) * Ultrapure / Pure Water * Water for Injection (WFI) * Water Measurement range 0,04 - 500 uS/cm Stainless steel 1.4435 (316L), FFKM FDA, … [Read more...] about CLS16D-3G1UG
CPM223-MR3105
Endress + Hauser CPM223-MR3105 Transmitter, pH/ORP Panel mounting: 96x96mm, front IP54 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CPM 223 MR Sensor Input; Software: Memosens, digital; pH(glass/ISFET) ORP basic version 3 Power Supply: … [Read more...] about CPM223-MR3105
CLS50-C1B1
Endress + Hauser CLS50-C1B1 Conductivity, inductive sensor Application: chemistry, waste water Measurement conductivity/concentration Highly resistant sensor material Quality certificate Endress Hauser CLS 50 C Approval: Non-hazardous area + EAC marking 1 Process Connection: … [Read more...] about CLS50-C1B1
CLD134-WBC550AA1
Endress + Hauser CLD134-WBC550AA1 Measuring system, conductivity Application: hygienic Food, pharma CIP control, phase separation Housing: stainless steel, IP67 Alarm output: relay Display: 2-line, 6 languages Sensor: inductive, PEEK, 0,1-2000mS/cm Process temp. max.125oC(short … [Read more...] about CLD134-WBC550AA1
CCM253-EP1005
Endress + Hauser CCM253-EP1005 Transmitter, chlorine/chlorine dioxide Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CCM 253 EP Sensor Input; Software: Cl2/ClO2 + pH/ORP; plus package 1 Power Supply: … [Read more...] about CCM253-EP1005
CPM223-PS5105
Endress + Hauser CPM223-PS5105 Transmitter, pH/ORP Panel mounting: 96x96mm, front IP54 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CPM 223 PS Sensor Input; Software: PH (glass) / ORP; plus package 5 Power Supply: 100VAC 1 Output: 2x … [Read more...] about CPM223-PS5105
CCM253-ES8325
Endress + Hauser CCM253-ES8325 Transmitter, chlorine/chlorine dioxide Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CCM 253 ES Sensor Input; Software: Cl2/ClO2; plus package 8 Power Supply: 24V AC/DC … [Read more...] about CCM253-ES8325
CPM253-PS2526
Endress + Hauser CPM253-PS2526 Transmitter, pH/ORP Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CPM 253 PS Sensor Input; Software: pH (glass) / ORP; plus package 2 Power Supply: 230VAC; CSA GenPurp … [Read more...] about CPM253-PS2526
CLS16D-3D1SG
Endress + Hauser CLS16D-3D1SG Conductivity, 2-electrode sensor Memosens functionality hygienic design, EHEDG Life Science, Water (Utilities) * Ultrapure / Pure Water * Water for Injection (WFI) * Water Measurement range 0,04 - 500 uS/cm Stainless steel 1.4435 (316L), FFKM FDA, … [Read more...] about CLS16D-3D1SG
CCM253-ES0005
Endress + Hauser CCM253-ES0005 Transmitter, chlorine/chlorine dioxide Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CCM 253 ES Sensor Input; Software: Cl2/ClO2; plus package 0 Power Supply: 230VAC … [Read more...] about CCM253-ES0005
CLS50-O1B2
Endress + Hauser CLS50-O1B2 Conductivity, inductive sensor Application: chemistry, waste water Measurement conductivity/concentration Highly resistant sensor material Quality certificate Endress Hauser CLS 50 O Approval: FM IS/NI Cl.I Div. 1/2 GP ABCD / Cl. I Zone 0 AEX ia IIC, Cl. … [Read more...] about CLS50-O1B2
CLS16D-4G1PG
Endress + Hauser CLS16D-4G1PG Conductivity, 2-electrode sensor Memosens functionality hygienic design, EHEDG Life Science, Water (Utilities) * Ultrapure / Pure Water * Water for Injection (WFI) * Water Measurement range 0,04 - 500 uS/cm Stainless steel 1.4435 (316L), FFKM FDA, … [Read more...] about CLS16D-4G1PG
CPM253-MS2326
Endress + Hauser CPM253-MS2326 Transmitter, pH/ORP Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CPM 253 MS Sensor Input; Software: Memosens; digital; pH(glass/ISFET) ORP, plus package 2 Power Supply: … [Read more...] about CPM253-MS2326
CLS50-A3C1
Endress + Hauser CLS50-A3C1 Conductivity, inductive sensor Application: chemistry, waste water Measurement conductivity/concentration Highly resistant sensor material Quality certificate Endress Hauser CLS 50 A Approval: Non-hazardous area 3 Process Connection: Flange EN1092-1 … [Read more...] about CLS50-A3C1
CLS16-3E2A1U
Endress + Hauser CLS16-3E2A1U Conductivity 2-electrode sensor Application: hygienic, pure water, ultrapure water FDA, EHEDG sterilizable ATEX II 1G EEx ia IIC T3/T4/T6 / FM Measuring range 0.04-500uS/cm, k=0.1 Process temp. max 120oC (short 150oC) Process pressure max. 12 bar … [Read more...] about CLS16-3E2A1U
CPM223-IS3105
Endress + Hauser CPM223-IS3105 Transmitter, pH/ORP Panel mounting: 96x96mm, front IP54 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CPM 223 IS Sensor Input; Software: PH (glass/ISFET) / ORP; plus package 3 Power Supply: 115VAC; CSA … [Read more...] about CPM223-IS3105
CPM253-MS2026
Endress + Hauser CPM253-MS2026 Transmitter, pH/ORP Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CPM 253 MS Sensor Input; Software: Memosens; digital; pH(glass/ISFET) ORP, plus package 2 Power Supply: … [Read more...] about CPM253-MS2026
CLD134-SAA550AA1
Endress + Hauser CLD134-SAA550AA1 Measuring system, conductivity Application: hygienic Food, pharma CIP control, phase separation Housing: stainless steel, IP67 Alarm output: relay Display: 2-line, 6 languages Sensor: inductive, PEEK, 0,1-2000mS/cm Process temp. max.125oC(short … [Read more...] about CLD134-SAA550AA1
CLS82D-AAHAA
Endress + Hauser CLS82D-AAHAA Conductivity, 4-electrode sensor Memosens functionality hygienic design, EHEDG, 3A Life Science, Food & Beverage, Water phase separation downstream processing fermentation Measurement range 1 µS/cm to 500 mS/cm Ceramics-platinium sensor element … [Read more...] about CLS82D-AAHAA
CM42-IVA000EAE00
Endress + Hauser CM42-IVA000EAE00 Transmitter liquid analysis Multiparameter, loop-powered Worldwide approvals, hazardous areas developed according to IEC 61508, pH/ORP, conductivity,oxygen (DO) digital sensors, Memosens protocol or analog sensors Field housing+panel mounting … [Read more...] about CM42-IVA000EAE00
CLS16-3G1A1U
Endress + Hauser CLS16-3G1A1U Conductivity 2-electrode sensor Application: hygienic, pure water, ultrapure water FDA, EHEDG sterilizable ATEX II 1G EEx ia IIC T3/T4/T6 / FM Measuring range 0.04-500uS/cm, k=0.1 Process temp. max 120oC (short 150oC) Process pressure max. 12 bar … [Read more...] about CLS16-3G1A1U
CLD134-PBC550AA1
Endress + Hauser CLD134-PBC550AA1 Measuring system, conductivity Application: hygienic Food, pharma CIP control, phase separation Housing: stainless steel, IP67 Alarm output: relay Display: 2-line, 6 languages Sensor: inductive, PEEK, 0,1-2000mS/cm Process temp. max.125oC(short … [Read more...] about CLD134-PBC550AA1
CLS16-4D1A1U
Endress + Hauser CLS16-4D1A1U Conductivity 2-electrode sensor Application: hygienic, pure water, ultrapure water FDA, EHEDG sterilizable ATEX II 1G EEx ia IIC T3/T4/T6 / FM Measuring range 0.04-500uS/cm, k=0.1 Process temp. max 120oC (short 150oC) Process pressure max. 12 bar … [Read more...] about CLS16-4D1A1U
CPM223-MR7105
Endress + Hauser CPM223-MR7105 Transmitter, pH/ORP Panel mounting: 96x96mm, front IP54 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CPM 223 MR Sensor Input; Software: Memosens, digital; pH(glass/ISFET) ORP basic version 7 Power Supply: … [Read more...] about CPM223-MR7105
CCM253-ES5310
Endress + Hauser CCM253-ES5310 Transmitter, chlorine/chlorine dioxide Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CCM 253 ES Sensor Input; Software: Cl2/ClO2; plus package 5 Power Supply: 100VAC … [Read more...] about CCM253-ES5310
COM253-DS0005
Endress + Hauser COM253-DS0005 Transmitter, dissolved oxygen DO Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser COM 253 DS Sensor Input; Software: COS41 (COS4/4HD); plus package 0 Power Supply: 230VAC … [Read more...] about COM253-DS0005