Endress + Hauser OUSAF44-F1A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 F Wavelength: 365 nm 1 Calibration/Validation: Easycal A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-F1A0
Endress + Hauser Analytics
Endress + Hauser CA72TOC -TOC analyzer
TURBIMAX CUS SENSORS FOR TURBIDITY MEASUREMENT
Process analytical technology pharmaceutical industry
CPS71-3TU4ESA
Endress + Hauser CPS71-3TU4ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TU4ESA
CLS16D-3G1U1
Endress + Hauser CLS16D-3G1U1 Conductivity, 2-electrode sensor Memosens functionality hygienic design, EHEDG Life Science, Water (Utilities) * Ultrapure / Pure Water * Water for Injection (WFI) * Water Measurement range 0,04 - 500 uS/cm Stainless steel 1.4435 (316L), FFKM FDA, … [Read more...] about CLS16D-3G1U1
COM253-DS3005
Endress + Hauser COM253-DS3005 Transmitter, dissolved oxygen DO Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser COM 253 DS Sensor Input; Software: COS41 (COS4/4HD); plus package 3 Power Supply: 115VAC; … [Read more...] about COM253-DS3005
CPS47D-AA8OCO2+JFL1
Endress + Hauser CPS47D-AA8OCO2+JFL1 pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramik, Reference: KCl liquid CPS47D-1061/0 Endress Hauser CPS 47D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 O Application … [Read more...] about CPS47D-AA8OCO2+JFL1
CPS71-3TC6ESA
Endress + Hauser CPS71-3TC6ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TC6ESA
COM223-WS3310
Endress + Hauser COM223-WS3310 Transmitter, dissolved oxygen DO Panel mounting: 96x96mm, front IP54 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser COM 223 WS Sensor Input; Software: COS31/COS61/COS71 (COS3/3HD), plus package 3 Power … [Read more...] about COM223-WS3310
CPS47D-AA8OCO5+Z1
Endress + Hauser CPS47D-AA8OCO5+Z1 pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramik, Reference: KCl liquid CPS47D-11K0/0 Endress Hauser CPS 47D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 O Application … [Read more...] about CPS47D-AA8OCO5+Z1
OUSAF11-AA105B1A10A
Endress + Hauser OUSAF11-AA105B1A10A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-1369/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA105B1A10A
OUSAF44-C1B0
Endress + Hauser OUSAF44-C1B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 C Wavelength: 295 nm 1 Calibration/Validation: Easycal B Lamp Approval: FM XP Cl. I Div. 1 … [Read more...] about OUSAF44-C1B0
CPS77D-AA8OHU4+JFL1
Endress + Hauser CPS77D-AA8OHU4+JFL1 pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramic, Reference: Gel CPS77D-11R8/0 Endress Hauser CPS 77D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 O Application Range: … [Read more...] about CPS77D-AA8OHU4+JFL1
CPS47D-AA8OCO5
Endress + Hauser CPS47D-AA8OCO5 pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramik, Reference: KCl liquid CPS47D-1014/0 Endress Hauser CPS 47D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 O Application … [Read more...] about CPS47D-AA8OCO5
CPS71-2TU5ESA
Endress + Hauser CPS71-2TU5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TU5ESA
COM253-DX7410
Endress + Hauser COM253-DX7410 Transmitter, dissolved oxygen DO Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser COM 253 DX Sensor Input; Software: COS41 4/4HD); basic version 7 Power Supply: 24V AC/DC; … [Read more...] about COM253-DX7410
OUSAF44-D0A0
Endress + Hauser OUSAF44-D0A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 D Wavelength: 302 nm 0 Calibration/Validation: Standard A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-D0A0
CPS47D-AA8OCO5+JFL1Z1
Endress + Hauser CPS47D-AA8OCO5+JFL1Z1 pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramik, Reference: KCl liquid CPS47D-11F2/0 Endress Hauser CPS 47D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 … [Read more...] about CPS47D-AA8OCO5+JFL1Z1
CLS16D-4E1R1
Endress + Hauser CLS16D-4E1R1 Conductivity, 2-electrode sensor Memosens functionality hygienic design, EHEDG Life Science, Water (Utilities) * Ultrapure / Pure Water * Water for Injection (WFI) * Water Measurement range 0,04 - 500 uS/cm Stainless steel 1.4435 (316L), FFKM FDA, … [Read more...] about CLS16D-4E1R1
OUSAF12-F1C0B
Endress + Hauser OUSAF12-F1C0B Color and NIR absorbance sensor, wavelength range 400-1500 nm Measuring range: up to 50 OD (depending on OPL) Light source: Low wattage incandescent lamp Endress Hauser OUSAF 12 F Wavelength: 950 nm 1 Calibration/validation: Easycal (1 filter) … [Read more...] about OUSAF12-F1C0B
COM223-DS2110
Endress + Hauser COM223-DS2110 Transmitter, dissolved oxygen DO Panel mounting: 96x96mm, front IP54 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser COM 223 DS Sensor Input; Software: COS41 (COS4/4HD); plus package 2 Power Supply: 230VAC; … [Read more...] about COM223-DS2110
CLD134-WAA540AA1
Endress + Hauser CLD134-WAA540AA1 Measuring system, conductivity Application: hygienic Food, pharma CIP control, phase separation Housing: stainless steel, IP67 Alarm output: relay Display: 2-line, 6 languages Sensor: inductive, PEEK, 0,1-2000mS/cm Process temp. max.125oC(short … [Read more...] about CLD134-WAA540AA1
CCM223-EP5310
Endress + Hauser CCM223-EP5310 Transmitter, chlorine/chlorine dioxide Panel mounting: 96x96mm, front IP54 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CCM 223 EP Sensor Input; Software: Cl2/ClO2 + pH/ORP; plus package 5 Power Supply: … [Read more...] about CCM223-EP5310
OUSAF44-D1B0
Endress + Hauser OUSAF44-D1B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 D Wavelength: 302 nm 1 Calibration/Validation: Easycal B Lamp Approval: FM XP Cl. I Div. 1 … [Read more...] about OUSAF44-D1B0
OUSAF12-F0D0A
Endress + Hauser OUSAF12-F0D0A Color and NIR absorbance sensor, wavelength range 400-1500 nm Measuring range: up to 50 OD (depending on OPL) Light source: Low wattage incandescent lamp Endress Hauser OUSAF 12 F Wavelength: 950 nm 0 Calibration/validation: Standard D Lamp: Gas … [Read more...] about OUSAF12-F0D0A
OUSBT66-AA05A2A
Endress + Hauser OUSBT66-AA05A2A NIR absorbance sensor Application: Cell growth, biomass Measuring range: up to 8 OD (dependent on OPL) Light source: LED, 880 nm Endress Hauser OUSBT 66 AA Approval: Non-hazardous area 05 Optical Pathlength (OPL): 5 mm A2 Diameter; Process … [Read more...] about OUSBT66-AA05A2A
CPS77D-AA8OHU2+JFL1Z1
Endress + Hauser CPS77D-AA8OHU2+JFL1Z1 pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramic, Reference: Gel CPS77D-1291/0 Endress Hauser CPS 77D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 O Application … [Read more...] about CPS77D-AA8OHU2+JFL1Z1
CPS71-2TU4ESA
Endress + Hauser CPS71-2TU4ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TU4ESA
CCM223-EK5310
Endress + Hauser CCM223-EK5310 Transmitter, chlorine/chlorine dioxide Panel mounting: 96x96mm, front IP54 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CCM 223 EK Sensor Input; Software: Cl2/ClO2; basic version 5 Power Supply: 100VAC … [Read more...] about CCM223-EK5310
CM42-KIC002EBF00
Endress + Hauser CM42-KIC002EBF00 Transmitter liquid analysis Multiparameter, loop-powered Worldwide approvals, hazardous areas developed according to IEC 61508, pH/ORP, conductivity,oxygen (DO) digital sensors, Memosens protocol or analog sensors Field housing+panel mounting … [Read more...] about CM42-KIC002EBF00
CPS41-3BC4ESA
Endress + Hauser CPS41-3BC4ESA pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 3 Electrode Type: Zero point Eo=7,0; with PT1000 sensor BC Application Range: 0-14pH, 0-130oC,3Diaphr.steril. 4 Shaft Length: … [Read more...] about CPS41-3BC4ESA
CPS77D-AA8OHU5+L1
Endress + Hauser CPS77D-AA8OHU5+L1 pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramic, Reference: Gel CPS77D-1102/0 Endress Hauser CPS 77D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 O Application Range: … [Read more...] about CPS77D-AA8OHU5+L1