Endress + Hauser CLS15D-B1AV Conductivity 2 electrode sensor Memosens functionality Signal transmission: digital Materials: 316L; PES Endress Hauser CLS 15D B Measuring Range; Cell Constant: 0.1-200uS/cm; k=0.1 1A Process Connection: thread NPT 1/2”; PES V Approval: ATEX / NEPSI … [Read more...] about CLS15D-B1AV
Endress + Hauser Analytics
Endress + Hauser CA72TOC -TOC analyzer
TURBIMAX CUS SENSORS FOR TURBIDITY MEASUREMENT
Process analytical technology pharmaceutical industry
CLS15D-A1AV
Endress + Hauser CLS15D-A1AV Conductivity 2 electrode sensor Memosens functionality Signal transmission: digital Materials: 316L; PES Endress Hauser CLS 15D A Measuring Range; Cell Constant: 0.04-20uS/cm; k=0.01 1A Process Connection: thread NPT 1/2”; PES V Approval: ATEX / … [Read more...] about CLS15D-A1AV
OUSAF44-E0B0
Endress + Hauser OUSAF44-E0B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 E Wavelength: 313 nm 0 Calibration/Validation: Standard B Lamp Approval: FM XP Cl. I Div. … [Read more...] about OUSAF44-E0B0
OUSAF44-A0C0
Endress + Hauser OUSAF44-A0C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 A Wavelength: 254 nm 0 Calibration/Validation: Standard C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-A0C0
OUSAF44-B0A0
Endress + Hauser OUSAF44-B0A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 B Wavelength: 280 nm 0 Calibration/Validation: Standard A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-B0A0
OUA260-BA1C04C4B3A
Endress + Hauser OUA260-BA1C04C4B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A1 Process Connection: Triclover 316L C Mean diameter: 0.5” 04 Optical Pathlength (OPL): 2 mm Standard C Window … [Read more...] about OUA260-BA1C04C4B3A
CCM253-ES0310
Endress + Hauser CCM253-ES0310 Transmitter, chlorine/chlorine dioxide Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CCM 253 ES Sensor Input; Software: Cl2/ClO2; plus package 0 Power Supply: 230VAC … [Read more...] about CCM253-ES0310
OUSAF44-E1A0
Endress + Hauser OUSAF44-E1A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 E Wavelength: 313 nm 1 Calibration/Validation: Easycal A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-E1A0
OUSAF12-A1D0A
Endress + Hauser OUSAF12-A1D0A Color and NIR absorbance sensor, wavelength range 400-1500 nm Measuring range: up to 50 OD (depending on OPL) Light source: Low wattage incandescent lamp Endress Hauser OUSAF 12 A Wavelength: 400 nm 1 Calibration/validation: Easycal (1 filter) … [Read more...] about OUSAF12-A1D0A
OUA260-BA2C05C4B3B
Endress + Hauser OUA260-BA2C05C4B3B Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A2 Process Connection: Triclover Kynar, non ex C Mean diameter: 0.5” 05 Optical Pathlength (OPL): 2 mm with POPL … [Read more...] about OUA260-BA2C05C4B3B
COM253-DS7410
Endress + Hauser COM253-DS7410 Transmitter, dissolved oxygen DO Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser COM 253 DS Sensor Input; Software: COS41 (COS4/4HD); plus package 7 Power Supply: 24V AC/DC; … [Read more...] about COM253-DS7410
CPS41-3BC2ESC
Endress + Hauser CPS41-3BC2ESC pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 3 Electrode Type: Zero point Eo=7,0; with PT1000 sensor BC Application Range: 0-14pH, 0-130oC,3Diaphr.steril. 2 Shaft Length: … [Read more...] about CPS41-3BC2ESC
OUSAF11-AA110B2A10A
Endress + Hauser OUSAF11-AA110B2A10A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2FL5/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA110B2A10A
CPS77D-AA8OHU4+JF
Endress + Hauser CPS77D-AA8OHU4+JF pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramic, Reference: Gel CPS77D-10A1/0 Endress Hauser CPS 77D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 O Application Range: … [Read more...] about CPS77D-AA8OHU4+JF
OUA260-BF1B03B2B3A
Endress + Hauser OUA260-BF1B03B2B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 F1 Process Connection: Tube Stub B Mean diameter: 0.375” 03 Optical Pathlength (OPL): 1 mm with POPL B Window … [Read more...] about OUA260-BF1B03B2B3A
CLS82D-BAPGA
Endress + Hauser CLS82D-BAPGA Conductivity, 4-electrode sensor Memosens functionality hygienic design, EHEDG, 3A Life Science, Food & Beverage, Water phase separation downstream processing fermentation Measurement range 1 µS/cm to 500 mS/cm Ceramics-platinium sensor element … [Read more...] about CLS82D-BAPGA
CPS341D-7A1LG
Endress + Hauser CPS341D-7A1LG pH-electrode with pH-sensitive enamel, hygienic design for food and pharma, CIP- and SIP-able, Memosens functionality, signal transmission digital with CYK10 cable, ground diaphragm, reference system Ag/AgCl, integrated temperature … [Read more...] about CPS341D-7A1LG
OUA260-BE1B08B2B3A
Endress + Hauser OUA260-BE1B08B2B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 E1 Process Connection: Swagelock BVCO B Mean diameter: 0.375” 08 Optical Pathlength (OPL): 10 mm Standard B Window … [Read more...] about OUA260-BE1B08B2B3A
OUSAF12-F1D0A
Endress + Hauser OUSAF12-F1D0A Color and NIR absorbance sensor, wavelength range 400-1500 nm Measuring range: up to 50 OD (depending on OPL) Light source: Low wattage incandescent lamp Endress Hauser OUSAF 12 F Wavelength: 950 nm 1 Calibration/validation: Easycal (1 filter) … [Read more...] about OUSAF12-F1D0A
OUA260-BA2C05C4B3A
Endress + Hauser OUA260-BA2C05C4B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A2 Process Connection: Triclover Kynar, non ex C Mean diameter: 0.5” 05 Optical Pathlength (OPL): 2 mm with POPL … [Read more...] about OUA260-BA2C05C4B3A
CPS341D-7A1B1
Endress + Hauser CPS341D-7A1B1 pH-electrode with pH-sensitive enamel, hygienic design for food and pharma, CIP- and SIP-able, Memosens functionality, signal transmission digital with CYK10 cable, ground diaphragm, reference system Ag/AgCl, integrated temperature … [Read more...] about CPS341D-7A1B1
CLS16D-4C1U1
Endress + Hauser CLS16D-4C1U1 Conductivity, 2-electrode sensor Memosens functionality hygienic design, EHEDG Life Science, Water (Utilities) * Ultrapure / Pure Water * Water for Injection (WFI) * Water Measurement range 0,04 - 500 uS/cm Stainless steel 1.4435 (316L), FFKM FDA, … [Read more...] about CLS16D-4C1U1
CLD18-DTXJ
Endress + Hauser CLD18-DTXJ Measuring system conductivity, inductive compact system Basic model Food industry, CIP control, phase separation economical attractive ::Extrusion-coat sensor ::FDA compliant material ::Remote configuration CLD18-1E81/0 Endress Hauser CLD 18 … [Read more...] about CLD18-DTXJ
OUA260-AA2A01B1A1A
Endress + Hauser OUA260-AA2A01B1A1A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 A Sensor type: for OUSAF44/OUSAF46 A2 Process Connection: Triclover Kynar, non ex A Mean diameter: 0.25” 01 Optical Pathlength (OPL): 0.5 mm with POPL … [Read more...] about OUA260-AA2A01B1A1A
CPS71-2TU4ESC
Endress + Hauser CPS71-2TU4ESC pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TU4ESC
CPS71-1TC5ESA
Endress + Hauser CPS71-1TC5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 1 Electrode Type: Zero point … [Read more...] about CPS71-1TC5ESA
CPS77D-AA8OHU4
Endress + Hauser CPS77D-AA8OHU4 pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramic, Reference: Gel CPS77D-1082/0 Endress Hauser CPS 77D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 O Application Range: … [Read more...] about CPS77D-AA8OHU4
OUSAF44-B1B0
Endress + Hauser OUSAF44-B1B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 B Wavelength: 280 nm 1 Calibration/Validation: Easycal B Lamp Approval: FM XP Cl. I Div. 1 … [Read more...] about OUSAF44-B1B0
CLS15D-L1M1
Endress + Hauser CLS15D-L1M1 Conductivity 2 electrode sensor Memosens functionality Signal transmission: digital Materials: 316L; PES Endress Hauser CLS 15D L Measuring Range; Cell Constant: PWIS free for k=0.1 PWIS=paint-wetting impairment substances 1M Process Connection: thread … [Read more...] about CLS15D-L1M1
CPS41-1BB4ESS
Endress + Hauser CPS41-1BB4ESS pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 1 Electrode Type: Zero point Eo=7.0 BB Application Range: 0-14pH;0-130oC,1diaph.,steriliz. also replacement for DB type … [Read more...] about CPS41-1BB4ESS