Endress + Hauser CPS41E-MA7BSC6 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-1587/0 Endress Hauser CPS 41E MA Approval: INMETRO Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-MA7BSC6
Endress + Hauser CPS41E Digital pH sensor - glass electrode for chemical and process industries
Endress + Hauser Digital pH sensor CPS41E features a liquid KCl electrolyte and a ceramic junction making it extremely suitable for harsh chemical applications. All shaft lengths with temperature sensor. Sensor shaft: Glass to suit process, pH membrane glass: Type A and B, Metal lead: Ag/AgCl, Open aperture: Ceramic junction, zirconium dioxide,
O-ring: FKM, process coupling: PPS fiber-glass reinforced, nameplate: Ceramic metal oxide.
CPS41E measured value
- pH
CPS41E application
• Chemical industry
• Organic chemicals
• Power plants, e.g. boiler feed water
• Laboratory measurements
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
CPS41E advantages
• Suitable for harsh conditions: Continuous refilling of KCl bridge electrolyte and a separate reference lead prevent poisoning of the electrode.
• Application in quickly changing media: Memosens CPS41E offers a fast response time thanks to its liquid KCl electrolyte and ceramic junction.
• Liquid KCl electrolyte enables reliable measurement even at very low conductivities (> 0.1 µS/cm).
• Suitable for cleaning in place (CIP) and sterilization in place (SIP)
• Inductive signal transmission eliminates any interference by moisture, leading to safer processes.
• Reduced operating costs: Sensor calibration and regeneration in the lab allows for less process downtime and extends the sensor lifetime.
CPS41E measuring range
Application A
• pH: 1 to 12
Application B
• pH: 0 to 14
CPS41E process temperature
Application B: 0 to 135 °C (32 to 275 °F)
CPS41E process pressure
CPS41E storage temperature
CPS41E-IA7ASC6
Endress + Hauser CPS41E-IA7ASC6 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry CPS41E-1545/0 Endress Hauser CPS 41E IA Approval: IECEx Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-IA7ASC6
CPS41E-BA7BSB6
Endress + Hauser CPS41E-BA7BSB6 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-14Q0/0 Endress Hauser CPS 41E BA Approval: ATEX II 1G Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-BA7BSB6
CPS41E-MA7BSC5
Endress + Hauser CPS41E-MA7BSC5 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-14F0/0 Endress Hauser CPS 41E MA Approval: INMETRO Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-MA7BSC5
CPS41E-CI7ASC4
Endress + Hauser CPS41E-CI7ASC4 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-13A9/0 Endress Hauser CPS 41E CI Approval: CSA C/US IS Cl. I Div. 1 GP A-D … [Read more...] about CPS41E-CI7ASC4
CPS41E-JA7ASB4
Endress + Hauser CPS41E-JA7ASB4 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry CPS41E-1306/0 Endress Hauser CPS 41E JA Approval: JPN Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-JA7ASB4
CPS41E-BA7BSC2
Endress + Hauser CPS41E-BA7BSC2 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-1191/0 Endress Hauser CPS 41E BA Approval: ATEX II 1G Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-BA7BSC2
CPS41E-BA7ASC2
Endress + Hauser CPS41E-BA7ASC2 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry CPS41E-1077/0 Endress Hauser CPS 41E BA Approval: ATEX II 1G Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-BA7ASC2