Endress + Hauser CPS41E-MA7BSB2 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-12K0/0 Endress Hauser CPS 41E MA Approval: INMETRO Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-MA7BSB2
Endress + Hauser CPS41E Digital pH sensor - glass electrode for chemical and process industries
Endress + Hauser Digital pH sensor CPS41E features a liquid KCl electrolyte and a ceramic junction making it extremely suitable for harsh chemical applications. All shaft lengths with temperature sensor. Sensor shaft: Glass to suit process, pH membrane glass: Type A and B, Metal lead: Ag/AgCl, Open aperture: Ceramic junction, zirconium dioxide,
O-ring: FKM, process coupling: PPS fiber-glass reinforced, nameplate: Ceramic metal oxide.
CPS41E measured value
- pH
CPS41E application
• Chemical industry
• Organic chemicals
• Power plants, e.g. boiler feed water
• Laboratory measurements
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
CPS41E advantages
• Suitable for harsh conditions: Continuous refilling of KCl bridge electrolyte and a separate reference lead prevent poisoning of the electrode.
• Application in quickly changing media: Memosens CPS41E offers a fast response time thanks to its liquid KCl electrolyte and ceramic junction.
• Liquid KCl electrolyte enables reliable measurement even at very low conductivities (> 0.1 µS/cm).
• Suitable for cleaning in place (CIP) and sterilization in place (SIP)
• Inductive signal transmission eliminates any interference by moisture, leading to safer processes.
• Reduced operating costs: Sensor calibration and regeneration in the lab allows for less process downtime and extends the sensor lifetime.
CPS41E measuring range
Application A
• pH: 1 to 12
Application B
• pH: 0 to 14
CPS41E process temperature
Application B: 0 to 135 °C (32 to 275 °F)
CPS41E process pressure
CPS41E storage temperature
CPS41E-IA7ASB2
Endress + Hauser CPS41E-IA7ASB2 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry CPS41E-1098/0 Endress Hauser CPS 41E IA Approval: IECEx Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-IA7ASB2
CPS41E-IA7ASC2
Endress + Hauser CPS41E-IA7ASC2 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-12P7/0 Endress Hauser CPS 41E IA Approval: IECEx Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-IA7ASC2
CPS41E-GR7ASB4
Endress + Hauser CPS41E-GR7ASB4 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry CPS41E-12W5/0 Endress Hauser CPS 41E GR Approval: Non-hazardous area + EAC marking … [Read more...] about CPS41E-GR7ASB4
CPS41E-BA7ASC4
Endress + Hauser CPS41E-BA7ASC4 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-1395/0 Endress Hauser CPS 41E BA Approval: ATEX II 1G Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-BA7ASC4
CPS41E-AA7ASB5
Endress + Hauser CPS41E-AA7ASB5 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-10E3/0 Endress Hauser CPS 41E AA Approval: Non-hazardous area 7 Electrode … [Read more...] about CPS41E-AA7ASB5
CPS41E-AA7ASB2
Endress + Hauser CPS41E-AA7ASB2 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry CPS41E-1020/0 Endress Hauser CPS 41E AA Approval: Non-hazardous area 7 Electrode Type: … [Read more...] about CPS41E-AA7ASB2
CPS41E-IA7BSB2
Endress + Hauser CPS41E-IA7BSB2 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-10N2/0 Endress Hauser CPS 41E IA Approval: IECEx Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-IA7BSB2
CPS41E-IA7BSC2
Endress + Hauser CPS41E-IA7BSC2 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-1144/0 Endress Hauser CPS 41E IA Approval: IECEx Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-IA7BSC2
CPS41E-MA7BSB4
Endress + Hauser CPS41E-MA7BSB4 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry CPS41E-1374/0 Endress Hauser CPS 41E MA Approval: INMETRO Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-MA7BSB4
CPS41E-IA7BSB5
Endress + Hauser CPS41E-IA7BSB5 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-1102/0 Endress Hauser CPS 41E IA Approval: IECEx Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-IA7BSB5
CPS41E-GR7BSB5
Endress + Hauser CPS41E-GR7BSB5 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry CPS41E-13X4/0 Endress Hauser CPS 41E GR Approval: Non-hazardous area + EAC marking … [Read more...] about CPS41E-GR7BSB5
CPS41E-GR7ASB2
Endress + Hauser CPS41E-GR7ASB2 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry CPS41E-1082/0 Endress Hauser CPS 41E GR Approval: Non-hazardous area + EAC marking … [Read more...] about CPS41E-GR7ASB2
CPS41E-MA7ASC2
Endress + Hauser CPS41E-MA7ASC2 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-12R8/0 Endress Hauser CPS 41E MA Approval: INMETRO Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-MA7ASC2
CPS41E-GR7BSC4
Endress + Hauser CPS41E-GR7BSC4 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-13K3/0 Endress Hauser CPS 41E GR Approval: Non-hazardous area + EAC marking … [Read more...] about CPS41E-GR7BSC4
CPS41E-GR7ASC2
Endress + Hauser CPS41E-GR7ASC2 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry CPS41E-12N6/0 Endress Hauser CPS 41E GR Approval: Non-hazardous area + EAC marking … [Read more...] about CPS41E-GR7ASC2
CPS41E-CI7BSB5
Endress + Hauser CPS41E-CI7BSB5 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-13W9/0 Endress Hauser CPS 41E CI Approval: CSA C/US IS Cl. I Div. 1 GP A-D … [Read more...] about CPS41E-CI7BSB5
CPS41E-IA7BSC6
Endress + Hauser CPS41E-IA7BSC6 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-10X7/0 Endress Hauser CPS 41E IA Approval: IECEx Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-IA7BSC6
CPS41E-JA7ASB6
Endress + Hauser CPS41E-JA7ASB6 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-14M8/0 Endress Hauser CPS 41E JA Approval: JPN Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-JA7ASB6
CPS41E-JA7ASC4
Endress + Hauser CPS41E-JA7ASC4 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-13E0/0 Endress Hauser CPS 41E JA Approval: JPN Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-JA7ASC4
CPS41E-MA7ASB5
Endress + Hauser CPS41E-MA7ASB5 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-13T2/0 Endress Hauser CPS 41E MA Approval: INMETRO Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-MA7ASB5
CPS41E-AA7ASC6
Endress + Hauser CPS41E-AA7ASC6 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-1503/0 Endress Hauser CPS 41E AA Approval: Non-hazardous area 7 Electrode … [Read more...] about CPS41E-AA7ASC6
CPS41E-JA7ASC5
Endress + Hauser CPS41E-JA7ASC5 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-1478/0 Endress Hauser CPS 41E JA Approval: JPN Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-JA7ASC5
CPS41E-BA7ASB2
Endress + Hauser CPS41E-BA7ASB2 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry CPS41E-1165/0 Endress Hauser CPS 41E BA Approval: ATEX II 1G Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-BA7ASB2
CPS41E-BA7ASB5
Endress + Hauser CPS41E-BA7ASB5 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-13P0/0 Endress Hauser CPS 41E BA Approval: ATEX II 1G Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-BA7ASB5
CPS41E-NA7BSC4
Endress + Hauser CPS41E-NA7BSC4 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-1265/0 Endress Hauser CPS 41E NA Approval: NEPSI Ex ia IIC T3/T4/T6 Ga … [Read more...] about CPS41E-NA7BSC4
CPS41E-GR7BSC6
Endress + Hauser CPS41E-GR7BSC6 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-10A1/0 Endress Hauser CPS 41E GR Approval: Non-hazardous area + EAC marking … [Read more...] about CPS41E-GR7BSC6
CPS41E-AA7ASC2
Endress + Hauser CPS41E-AA7ASC2 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry CPS41E-1150/0 Endress Hauser CPS 41E AA Approval: Non-hazardous area 7 Electrode Type: … [Read more...] about CPS41E-AA7ASC2
CPS41E-AA7BSC6
Endress + Hauser CPS41E-AA7BSC6 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-11E7/0 Endress Hauser CPS 41E AA Approval: Non-hazardous area 7 Electrode … [Read more...] about CPS41E-AA7BSC6
CPS41E-CI7ASC5
Endress + Hauser CPS41E-CI7ASC5 pH glass comb. sensor, Memosens 2.0. Junction: Ceramic. Signal transmission: Digital. Reference system: Ag/AgCl, liquid KCl. 1 or 3 junctions. Process Industry. CPS41E-1441/0 Endress Hauser CPS 41E CI Approval: CSA C/US IS Cl. I Div. 1 GP A-D … [Read more...] about CPS41E-CI7ASC5