Endress + Hauser CM442R-CAM2A1FA7 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CAM2A1FA7
Endress + Hauser Liquiline CM14 pH, oxygen O2 and Conductivity measuring kits
- pH measuring kits
- Conductivity measuring kits
- Oxygen O2 measuring Kit
71136420 - CM14 pH-Kit 1 complete measuring loop Transmitter, 10m measuring cable, digital sensor pH comb.Electrode CPS11D,A-glass 1-12 pH Memosens
71136421 - CM14 pH-Kit 2 complete measuring loop Transmitter, 10m measuring cable, digital sensor pH comb.Electrode CPS11D,B-glass 1-14 pH Memosens
71136419 - CM14 pH-Kit 3 complete measuring loop Transmitter, 10m measuring cable, digital sensor pH sensor CPF 81D, 0-11 pH Memosens
71136251 - CM14 conductivity Kit 1, conductive complete measuring loop Transmitter, 10m measuring cable, digital sensor conductivity sensor CLS15D, k=0,01 1/cm Memosens
71136252 - CM14 conductivity Kit 2, conductive complete measuring loop Transmitter, 10m measuring cable digital sensor conductivity sensor CLS15D, k=0,1 1/cm Memosens
71136253 - CM14 conductivity Kit 3, inductive complete measuring loop Transmitter, digital sensor conductivity sensor CLS50D, Memosens
71136585 - CM14 DO Kit 1 complete measuring loop Transmitter, 10m measuring cable digital sensor DO sensor COS51D, Memosens
Liquiline CM14 kits application:
Liquiline CM14 is a 4-wire-controller in compact design for installation in panels or cabinets in following industries:
• Wastewater treatment
• Water treatment and drinking water monitoring
• Ion exchanger
• Surface water monitoring
Liquiline CM14 sensors:
Glass electrodes pH measurement
Orbisint CPS11D
• pH electrode for process applications with Memosens technology
• Dirt-repellent PTFE diaphragm
• Ordering acc. to product structure, see Technical Information (TI028C/07/en)
CM42 1-channel-transmitter for pH/ORP, conductivity or oxygen measurement
Orbipore CPS91D
• pH sensor with Memosens technology
• With open aperture for media with high dirt load
• Ordering acc. to product structure, see Technical Information (TI375C/07/en)
Orbipac CPF81D
• Compact pH sensor for installation or immersion operation in process water and wastewater
• Ordering acc. to product structure, see Technical Information (TI191C/07/en)
ORP sensors
Orbisint CPS12D
• ORP sensor with Memosens technology
• Dirt-repellent PTFE diaphragm
• Ordering acc. to product structure, see Technical Information (TI367C/07/en)
Orbipore CPS92D
• ORP sensor with Memosens technology
• With open aperture for media with high dirt load
• Ordering acc. to product structure, see Technical Information (TI435C/07/en)
Orbipac CPF82D
• Compact ORP sensor for installation or immersion operation in process water and wastewater
• Ordering acc. to product structure, see Technical Information (TI191C/07/en)
Conductivity sensors, conductive
Condumax W CLS15D
• For measurement in pure and ultrapure water and in Ex applications
• Ordering according to product structure, see Technical Information TI109C/07/en
Condumax H CLS16D
• Hygienic sensor for measurement in pure and ultrapure water and in Ex applications
• With EHEDG and 3A certificates
• Ordering according to product structure, see Technical Information TI227C/07/en
Condumax W CLS21D
• Two-electrode sensor in fixed cable and plug-in head version
• Ordering according to product structure, see Technical Information TI085C/07/en
Conductivity sensors, inductive
Indumax CLS50D
• High-stability inductive conductivity sensor for standard, Ex and high-temperature applications
• Memosens technology
• Order as per product structure, see Technical Information TI182C/07/en
Oxygen sensors
Oxymax COS51D
• Amperometric sensor for dissolved oxygen, with Memosens technology
• Ordering acc. to product structure, see Technical Information (TI413C/07/en)
Oxymax H COS22D
• Sterilizable sensor for dissolved oxygen, with Memosens technology
• Ordering acc. to product structure, see Technical Information (TI446C/07/en)
Liquiline transmitter
1-channel transmitter CM42
1- / 2-channel transmitter CM442R
8-channel transmitter CM448
8-channel transmitter CM448R
CM442R-AAM2A1FA7
Endress + Hauser CM442R-AAM2A1FA7 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-AAM2A1FA7
CM442R-AAM2A1FA1
Endress + Hauser CM442R-AAM2A1FA1 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-AAM2A1FA1
CM442R-CAM1A1FD6
Endress + Hauser CM442R-CAM1A1FD6 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CAM1A1FD6
CM442R-CDM1A1FD7
Endress + Hauser CM442R-CDM1A1FD7 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CDM1A1FD7
CM442R-AAM1A1FD1
Endress + Hauser CM442R-AAM1A1FD1 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-AAM1A1FD1
CM442R-GRM1A1FA1
Endress + Hauser CM442R-GRM1A1FA1 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-GRM1A1FA1
CM442R-CAM1A1FD7
Endress + Hauser CM442R-CAM1A1FD7 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CAM1A1FD7
CM442R-GRM1A1FA6
Endress + Hauser CM442R-GRM1A1FA6 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-GRM1A1FA6
CM442R-AAM2A1FD1
Endress + Hauser CM442R-AAM2A1FD1 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-AAM2A1FD1
CM442R-CDM1A1FA6
Endress + Hauser CM442R-CDM1A1FA6 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CDM1A1FA6
CM442R-CDM2A1FA7
Endress + Hauser CM442R-CDM2A1FA7 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CDM2A1FA7
CM442R-CAM1A1FA1
Endress + Hauser CM442R-CAM1A1FA1 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CAM1A1FA1
CM442R-GRM2A1FD7
Endress + Hauser CM442R-GRM2A1FD7 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-GRM2A1FD7
CM442R-GRM2A1FA1
Endress + Hauser CM442R-GRM2A1FA1 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-GRM2A1FA1
CM442R-CAM1A1FD1
Endress + Hauser CM442R-CAM1A1FD1 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CAM1A1FD1
CM442R-CAM1A1FA6
Endress + Hauser CM442R-CAM1A1FA6 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CAM1A1FA6
CM442R-CAM2A1FD6
Endress + Hauser CM442R-CAM2A1FD6 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CAM2A1FD6
CM442R-CDM1A1FA1
Endress + Hauser CM442R-CDM1A1FA1 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CDM1A1FA1
CM442R-CDM2A1FA6
Endress + Hauser CM442R-CDM2A1FA6 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CDM2A1FA6
CM442R-GRM1A1FD7
Endress + Hauser CM442R-GRM1A1FD7 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-GRM1A1FD7
CM442R-CDM2A1FD6
Endress + Hauser CM442R-CDM2A1FD6 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CDM2A1FD6
CM442R-CAM1A1FA7
Endress + Hauser CM442R-CAM1A1FA7 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CAM1A1FA7
CM442R-CAM2A1FA1
Endress + Hauser CM442R-CAM2A1FA1 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CAM2A1FA1
CM442R-AAM1A1FA7
Endress + Hauser CM442R-AAM1A1FA7 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-AAM1A1FA7
CM442R-CDM1A1FA7
Endress + Hauser CM442R-CDM1A1FA7 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-CDM1A1FA7
CM442R-GRM2A1FD6
Endress + Hauser CM442R-GRM2A1FD6 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-GRM2A1FD6
CM442R-GRM1A1FA7
Endress + Hauser CM442R-GRM1A1FA7 Transmitter liquid analysis for rail-mount/cabinet installation Multiparameter + Multichannel applicable for process control, pH/ORP, conductivity, turbidity oxygen(DO), disinfection, SAC, nitrate, ammonia. Digital sensors; Memosens … [Read more...] about CM442R-GRM1A1FA7
CM42-KJA602EBD01
Endress + Hauser CM42-KJA602EBD01 Transmitter liquid analysis Multiparameter, loop-powered Worldwide approvals, hazardous areas developed according to IEC 61508, pH/ORP, conductivity,oxygen (DO) digital sensors, Memosens protocol or analog sensors Field housing+panel mounting … [Read more...] about CM42-KJA602EBD01
CM42-NJA602EBD00
Endress + Hauser CM42-NJA602EBD00 Transmitter liquid analysis Multiparameter, loop-powered Worldwide approvals, hazardous areas developed according to IEC 61508, pH/ORP, conductivity,oxygen (DO) digital sensors, Memosens protocol or analog sensors Field housing+panel mounting … [Read more...] about CM42-NJA602EBD00