Endress + Hauser CPS47D-AA8OCO5+JFL1 pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramik, Reference: KCl liquid CPS47D-11C6/0 Endress Hauser CPS 47D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 … [Read more...] about CPS47D-AA8OCO5+JFL1
Endress + Hauser Field instruments designed to control automation processes E+H
E+H, the people who know how to design field instruments to control automation processes in your plant. Endress + Hauser's main product lines are:
- - Endress + Hauser Analytics
(TOC, COD and SAC analyzers, process photometers, pH sensors and transmitters, ORP sensors and transmitters, nutrient analyzers and sensors, analyzers for hardness, iron, aluminum, chromate and sodium,
conductivity sensors and transmitters, oxygen sensors and transmitters, turbidity sensors and transmitters, chlorine sensors and transmitters, automatic water samplers, sludge level sensors and transmitters) - Sensors / Electrodes
- Memosens Cable Digital data and extension cable
- Liquisys Transmitter
- Smartec measuring system for inductive conductivity
- Indumax Sensors
- - Flow measurement
- - Endress + Hauser Level measurement
(Guided radar, radar, ultrasonic, vibronic point level detection, capacitance level, servo level, conductive level, radiometric level, electromechanical level, float switch level, paddle switch level, microwave barrier level, 113GHz + your Wavelength) - Endress+Hauser Liquiphant
- Endress+Hauser Soliphant
- Endress+Hauser Liquicap
- Prosonic FMU40 FMU41 FMU42 FMU43 FMU44 FMU95 FDU30 FDU90 FDU91F FDU92 FDU93 FDU95 FDU
- Liquipoint
- Micropilot
- - Endress + Hauser Pressure measurement
(Absolute and gauge pressure measurement, hydrostatic level measurement with pressure transmitters for liquid applications, differential pressure measurement) - Cerabar
- Ceraphant
- Deltabar
- Deltapilot
- - System products
- - Endress + Hauser temperature measurement
- iTHERM Endress + Hauser hygienic resistance thermometer with various measuring ranges, with or without thermowell, especially for for use in the food/beverages
and pharmaceutical industries. - Omnigrad
Comprehensive and common temperature measurement technology for almost all branches of industry - Thermophant
- Easytemp Thermometer
t-mass thermal mass flowmeter
Promass Coriolis flowmeter
Promag 50 Electromagnetic flowmeter
Promag 53 Electromagnetic flowmeter
Ecograph Data recorder
Tank gauging instruments
CPS41-2AB4ESS
Endress + Hauser CPS41-2AB4ESS pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS41 2 Electrode Type: Zero point Eo=7.0 + Pt100 AB Application Range: 1-12pH; -15-80oC,1 diaphragm 4 Shaft Length: 225mm … [Read more...] about CPS41-2AB4ESS
OUSAF12-B0D0A
Endress + Hauser OUSAF12-B0D0A Color and NIR absorbance sensor, wavelength range 400-1500 nm Measuring range: up to 50 OD (depending on OPL) Light source: Low wattage incandescent lamp Endress Hauser OUSAF 12 B Wavelength: 420 nm 0 Calibration/validation: Standard D Lamp: Gas … [Read more...] about OUSAF12-B0D0A
OUSAF11-AA105A3A15A
Endress + Hauser OUSAF11-AA105A3A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-13M4/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA105A3A15A
CPS77D-AA8OHU2+JFL1
Endress + Hauser CPS77D-AA8OHU2+JFL1 pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramic, Reference: Gel CPS77D-10L1/0 Endress Hauser CPS 77D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 O Application Range: … [Read more...] about CPS77D-AA8OHU2+JFL1
CPS71-3TC4ESA
Endress + Hauser CPS71-3TC4ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TC4ESA
OUSAF44-E0C0
Endress + Hauser OUSAF44-E0C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 E Wavelength: 313 nm 0 Calibration/Validation: Standard C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-E0C0
COM253-WX1005
Endress + Hauser COM253-WX1005 Transmitter, dissolved oxygen DO Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser COM 253 WX Sensor Input; Software: COS31/COS61/COS71 (COS3/3HD); basic version 1 Power … [Read more...] about COM253-WX1005
CPS41-3AC4ESA
Endress + Hauser CPS41-3AC4ESA pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 3 Electrode Type: Zero point Eo=7,0; with PT1000 sensor AC Application Range: 1-12pH; -15-80oC, 3 diaphragms 4 Shaft Length: … [Read more...] about CPS41-3AC4ESA
OUSAF12-F1D0B
Endress + Hauser OUSAF12-F1D0B Color and NIR absorbance sensor, wavelength range 400-1500 nm Measuring range: up to 50 OD (depending on OPL) Light source: Low wattage incandescent lamp Endress Hauser OUSAF 12 F Wavelength: 950 nm 1 Calibration/validation: Easycal (1 filter) … [Read more...] about OUSAF12-F1D0B
OUSAF11-AA105C1A10A
Endress + Hauser OUSAF11-AA105C1A10A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-1MT0/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA105C1A10A
OUSAF44-F0A0
Endress + Hauser OUSAF44-F0A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress + Hauser OUSAF44-F0A0 F Wavelength: 365 nm 0 Calibration/Validation: Standard A Lamp Approval: … [Read more...] about OUSAF44-F0A0
CPS41-2AC4ESS
Endress + Hauser CPS41-2AC4ESS pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 2 Electrode Type: Zero point Eo=7.0 + Pt100 AC Application Range: 1-12pH; -15-80oC, 3 diaphragms 4 Shaft Length: 225mm … [Read more...] about CPS41-2AC4ESS
CPS341D-7A1H1
Endress + Hauser CPS341D-7A1H1 pH-electrode with pH-sensitive enamel, hygienic design for food and pharma, CIP- and SIP-able, Memosens functionality, signal transmission digital with CYK10 cable, ground diaphragm, reference system Ag/AgCl, integrated temperature … [Read more...] about CPS341D-7A1H1
OUSAF12-X0C0B
Endress + Hauser OUSAF12-X0C0B Color and NIR absorbance sensor, wavelength range 400-1500 nm Measuring range: up to 50 OD (depending on OPL) Light source: Low wattage incandescent lamp Endress Hauser OUSAF 12 X Wavelength: Long Pass NIR (only NIR) 0 Calibration/validation: … [Read more...] about OUSAF12-X0C0B
OUSAF11-AA110A1A10A
Endress + Hauser OUSAF11-AA110A1A10A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-10W1/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA110A1A10A
CLD18-ATXJ
Endress + Hauser CLD18-ATXJ Measuring system conductivity, inductive compact system Basic model Food industry, CIP control, phase separation economical attractive ::Extrusion-coat sensor ::FDA compliant material ::Remote configuration CLD18-1102/0 Endress Hauser CLD 18 … [Read more...] about CLD18-ATXJ
OUSAF44-B1C0
Endress + Hauser OUSAF44-B1C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 B Wavelength: 280 nm 1 Calibration/Validation: Easycal C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-B1C0
CPS71-3TB4ESA
Endress + Hauser CPS71-3TB4ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TB4ESA
CPS77D-AA8OHU5+JFL1Z1
Endress + Hauser CPS77D-AA8OHU5+JFL1Z1 pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramic, Reference: Gel CPS77D-12A5/0 Endress Hauser CPS 77D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 O Application … [Read more...] about CPS77D-AA8OHU5+JFL1Z1
OUSAF12-B1D0A
Endress + Hauser OUSAF12-B1D0A Color and NIR absorbance sensor, wavelength range 400-1500 nm Measuring range: up to 50 OD (depending on OPL) Light source: Low wattage incandescent lamp Endress Hauser OUSAF 12 B Wavelength: 420 nm 1 Calibration/validation: Easycal (1 filter) … [Read more...] about OUSAF12-B1D0A
CLS50-OAC3
Endress + Hauser CLS50-OAC3 Conductivity, inductive sensor Application: chemistry, waste water Measurement conductivity/concentration Highly resistant sensor material Quality certificate Endress Hauser CLS 50 O Approval: FM IS/NI Cl.I Div. 1/2 GP ABCD / Cl. I Zone 0 AEX ia IIC, Cl. … [Read more...] about CLS50-OAC3
COM253-WS3005
Endress + Hauser COM253-WS3005 Transmitter, dissolved oxygen DO Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser COM 253 WS Sensor Input; Software: COS31/COS61/COS71 (COS3/3HD) plus package 3 Power Supply: … [Read more...] about COM253-WS3005
OUSAF11-AA105A3A10A
Endress + Hauser OUSAF11-AA105A3A10A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-1K95/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA105A3A10A
CPS41-3AC4ESS
Endress + Hauser CPS41-3AC4ESS pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 3 Electrode Type: Zero point Eo=7,0; with PT1000 sensor AC Application Range: 1-12pH; -15-80oC, 3 diaphragms 4 Shaft Length: … [Read more...] about CPS41-3AC4ESS
OUSBT66-AA05A1A+Z1
Endress + Hauser OUSBT66-AA05A1A+Z1 NIR absorbance sensor Application: Cell growth, biomass Measuring range: up to 8 OD (dependent on OPL) Light source: LED, 880 nm OUSBT66-10U0/0 Endress Hauser OUSBT 66 AA Approval: Non-hazardous area 05 Optical Pathlength (OPL): 5 mm … [Read more...] about OUSBT66-AA05A1A+Z1
OUSAF44-C0A0
Endress + Hauser OUSAF44-C0A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 C Wavelength: 295 nm 0 Calibration/Validation: Standard A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-C0A0
OUSAF22-B0C1B
Endress + Hauser OUSAF22-B0C1B Dual wavelengths absorbance sensor Wavelength range: 390-1100 nm. Measuring range: up to 50 OD (dep.on OPL). Light source: Low wattage incandescent lamp OUSAF22-12E7/0 Endress Hauser OUSAF 22 B Wavelength Combination: 490/720 nm … [Read more...] about OUSAF22-B0C1B
CPS77D-AA8OHU4+Z1
Endress + Hauser CPS77D-AA8OHU4+Z1 pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramic, Reference: Gel CPS77D-11C6/0 Endress Hauser CPS 77D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 O Application Range: … [Read more...] about CPS77D-AA8OHU4+Z1
OUSAF12-X1D0B
Endress + Hauser OUSAF12-X1D0B Color and NIR absorbance sensor, wavelength range 400-1500 nm Measuring range: up to 50 OD (depending on OPL) Light source: Low wattage incandescent lamp Endress Hauser OUSAF 12 X Wavelength: Long Pass NIR (only NIR) 1 Calibration/validation: … [Read more...] about OUSAF12-X1D0B