Endress + Hauser FMD78 Electronic differential pressure Deltabar - with two diaphragm seals for differential pressure and level

ENDRESS + HAUSER FMD78 Level measurement Deltapilot

Endress + Hauser Deltabar FMD78 differential pressure transmitter with metal sensor uses two capillary diaphragm seals. Typically used in process and hygiene applications for continuous measurement of pressure differences in liquids, vapors, gases and dusts.
Digital transmitter with metallic measuring diaphragms diaphragm seals and capillaries. Modular transmitter. Long term stability. Enhanced safety via self diagnostic functions. Secondary process barrier.

Endress + Hauser FMD78 measuring principle:

Differential pressure

Endress + Hauser FMD78 measuring range:

100mbar...40bar (1.5psi ... 600 psi)

Endress + Hauser FMD78 application:

For differential pressure, level, volume or mass measurement in liquids.
• Process connections: Threads, flanges, pancake and hygienic connections
• Process temperature: -70 up to +400°C (-94 to +752°F)
• Measuring ranges: 100mbar to +40 bar (1.5 to 600psi)
• Accuracy: ±0.075%
• International explosion protection certificates, overfill prevention WHG, hygienic approvals, marine approvals, SIL

Endress + Hauser FMD78 advantages:

• Large variety of different process connections and membrane materials
• New TempC Membrane for diaphragm seals: Minimum temperature effects and short recovery times
• Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
• Easy menu-guided commissioning via local display, 4 to 20 mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
• HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
• Cost savings with modular concept for easy replacement of sensor, display or electronics
• Seamless and independent system integration (HART/PA/FF)

Endress + Hauser FMD78 process temperature:

-40°C...400°C (-40°F...752°F)

Endress + Hauser FMD78 pressure absolute / max. overpressure limit:

Process pressure absolute / max. overpressure limit 160bar (2400 psi)

FMD78-IA27DBEAF1CU

© E+H Differential pressure transmitter with two diaphragm seals FMD78-IA27DBEAF1CU

Endress + Hauser FMD78-IA27DBEAF1CU Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-IA27DBEAF1CU

FMD78-1A27DBEAF1CN

© E+H Differential pressure transmitter with two diaphragm seals FMD78-1A27DBEAF1CN

Endress + Hauser FMD78-1A27DBEAF1CN Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: Modular Endress Hauser FMD … [Read more...] about FMD78-1A27DBEAF1CN

FMD78-IAA7FBEAF2C3

© E+H Differential pressure transmitter with two diaphragm seals FMD78-IAA7FBEAF2C3

Endress + Hauser FMD78-IAA7FBEAF2C3 Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-IAA7FBEAF2C3

FMD78-1A27DBEAF1CQ

© E+H Differential pressure transmitter with two diaphragm seals FMD78-1A27DBEAF1CQ

Endress + Hauser FMD78-1A27DBEAF1CQ Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-1A27DBEAF1CQ

FMD78-AAA7FBEAF2CG

© E+H Differential pressure transmitter with two diaphragm seals FMD78-AAA7FBEAF2CG

Endress + Hauser FMD78-AAA7FBEAF2CG Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-AAA7FBEAF2CG

FMD78-1A27DBEAF1CJ

© E+H Differential pressure transmitter with two diaphragm seals FMD78-1A27DBEAF1CJ

Endress + Hauser FMD78-1A27DBEAF1CJ Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-1A27DBEAF1CJ

FMD78-6B27DBEAF1C3

© E+H Differential pressure transmitter with two diaphragm seals FMD78-6B27DBEAF1C3

Endress + Hauser FMD78-6B27DBEAF1C3 Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity :: High static pressure + overload safety. :: … [Read more...] about FMD78-6B27DBEAF1C3

FMD78-SC27DBEAF1CA

© E+H Differential pressure transmitter with two diaphragm seals FMD78-SC27DBEAF1CA

Endress + Hauser FMD78-SC27DBEAF1CA Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-SC27DBEAF1CA

FMD78-IAA7FBEAF2CG

© E+H Differential pressure transmitter with two diaphragm seals FMD78-IAA7FBEAF2CG

Endress + Hauser FMD78-IAA7FBEAF2CG Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-IAA7FBEAF2CG

FMD78-IAA7FBEAF2CU

© E+H Differential pressure transmitter with two diaphragm seals FMD78-IAA7FBEAF2CU

Endress + Hauser FMD78-IAA7FBEAF2CU Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-IAA7FBEAF2CU

FMD78-UD27DBEAF1CA

© E+H Differential pressure transmitter with two diaphragm seals FMD78-UD27DBEAF1CA

Endress + Hauser FMD78-UD27DBEAF1CA Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-UD27DBEAF1CA

FMD78-UDA7FBEAF2CG

© E+H Differential pressure transmitter with two diaphragm seals FMD78-UDA7FBEAF2CG

Endress + Hauser FMD78-UDA7FBEAF2CG Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-UDA7FBEAF2CG

FMD78-IAA7FBEAF2CS

© E+H Differential pressure transmitter with two diaphragm seals FMD78-IAA7FBEAF2CS

Endress + Hauser FMD78-IAA7FBEAF2CS Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-IAA7FBEAF2CS

FMD78-AAA7FBEAF2CJ

© E+H Differential pressure transmitter with two diaphragm seals FMD78-AAA7FBEAF2CJ

Endress + Hauser FMD78-AAA7FBEAF2CJ Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-AAA7FBEAF2CJ

FMD78-UDA7FBEAF2C3

© E+H Differential pressure transmitter with two diaphragm seals FMD78-UDA7FBEAF2C3

Endress + Hauser FMD78-UDA7FBEAF2C3 Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-UDA7FBEAF2C3

FMD78-AAA7FBEAF2CA

© E+H Differential pressure transmitter with two diaphragm seals FMD78-AAA7FBEAF2CA

Endress + Hauser FMD78-AAA7FBEAF2CA Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-AAA7FBEAF2CA

FMD78-AAA7FBEAF2CQ

Endress + Hauser FMD78-AAA7FBEAF2CQ Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: Modular. Differential pressure. Diaphragm seal + … [Read more...] about FMD78-AAA7FBEAF2CQ

FMD78-SCA7FBEAF2CA

© E+H Differential pressure transmitter with two diaphragm seals FMD78-SCA7FBEAF2CA

Endress + Hauser FMD78-SCA7FBEAF2CA Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-SCA7FBEAF2CA

FMD78-SCA7FBEAF2CE

© E+H Differential pressure transmitter with two diaphragm seals FMD78-SCA7FBEAF2CE

Endress + Hauser FMD78-SCA7FBEAF2CE Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-SCA7FBEAF2CE

FMD78-UD27DBEAF1CM

Endress + Hauser FMD78-UD27DBEAF1CM Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-UD27DBEAF1CM

FMD78-6B27DBEAF1CU

© E+H Differential pressure transmitter with two diaphragm seals FMD78-6B27DBEAF1CU

Endress + Hauser FMD78-6B27DBEAF1CU Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-6B27DBEAF1CU

FMD78-1A27DBEAF1CG

© E+H Differential pressure transmitter with two diaphragm seals FMD78-1A27DBEAF1CG

Endress + Hauser FMD78-1A27DBEAF1CG Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-1A27DBEAF1CG

FMD78-6B27DBEAF1C4

© E+H Differential pressure transmitter with two diaphragm seals FMD78-6B27DBEAF1C4

Endress + Hauser FMD78-6B27DBEAF1C4 Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-6B27DBEAF1C4

FMD78-6B27DBEAF1CS

© E+H Differential pressure transmitter with two diaphragm seals FMD78-6B27DBEAF1CS

Endress + Hauser FMD78-6B27DBEAF1CS Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-6B27DBEAF1CS

FMD78-1A27DBEAF1CS

© E+H Differential pressure transmitter with two diaphragm seals FMD78-1A27DBEAF1CS

Endress + Hauser FMD78-1A27DBEAF1CS Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety :: … [Read more...] about FMD78-1A27DBEAF1CS

FMD78-IA27DBEAF1CN

© E+H Differential pressure transmitter with two diaphragm seals FMD78-IA27DBEAF1CN

Endress + Hauser FMD78-IA27DBEAF1CN Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-IA27DBEAF1CN

FMD78-6B27DBEAF1CQ

© E+H Differential pressure transmitter with two diaphragm seals FMD78-6B27DBEAF1CQ

Endress + Hauser FMD78-6B27DBEAF1CQ Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-6B27DBEAF1CQ

FMD78-IA27DBEAF1C3

© E+H Differential pressure transmitter with two diaphragm seals FMD78-IA27DBEAF1C3

Endress + Hauser FMD78-IA27DBEAF1C3 Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-IA27DBEAF1C3

FMD78-1A27DBEAF1CA

© E+H Differential pressure transmitter with two diaphragm seals FMD78-UD27DBEAF1CA

Endress + Hauser FMD78-1A27DBEAF1CA Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-1A27DBEAF1CA

FMD78-1A27DBEAF1CE

© E+H Differential pressure transmitter with two diaphragm seals FMD78-1A27DBEAF1CE

Endress + Hauser FMD78-1A27DBEAF1CE Differential pressure. Diaphragm seal + capillary. Application: level, hydrostatic. Secondary process barrier. :: High long term stability. :: Enhanced mechanical integrity. :: High static pressure + overload safety. :: … [Read more...] about FMD78-1A27DBEAF1CE

  • Go to page 1
  • Go to page 2
  • Go to Next Page »

Primary Sidebar

Contact us:





    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • CM444R-CDM4BA1FK6
    • CPS16E-KA7ATA2
    • CPS16E-NA7ATA4
    • CPS16E-GR7BTA4
    • CM444R-CAM4BA5FA1
    • CPS16E-JA7ATA4
    • CPS92E-BA7PHH5+Z1
    • CPS16E-CB7ATA4
    • CPS92E-UA7PHH4+Z1
    • CPS41E-NA7ASC5
    • 10D25-3TGA1AA0A0BA
    • CPS92E-UA7PHH2+Z1
    • CPS41E-JA7BSB4
    • 10D25-6VGAEAA0A0BA
    • CPS92E-MA7PHH5
    • CPS92E-IA7PHH2
    • CPS41E-IA7BSB4
    • 10D25-7LGA1AA0A0BA
    • CPS92E-MA7PHH4
    • CPS41E-BA7ASB4

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2023 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.