Endress + Hauser FTL825-UR3E4 FailSafe level instrument point level. Top hat rail mounting. Connection to FTL80/FTL81/FTL85. :: SIL3 according to IEC61508. :: Permanent self-monitoring, LIVE-Signal. FTL825-18M2/0 Endress Hauser FTL82 UR Approval: Non-hazardous area + UK marking … [Read more...] about FTL825-UR3E4
Endress + Hauser Level measurement

- Endress+Hauser Liquiphant
- Endress+Hauser Soliphant
- Endress+Hauser Liquicap
- Liquipoint
- QMW43 LIQUITREND
Guided radar measurement Levelflex
Micropilot
FTI77-U1AEBRG111A1A
Endress + Hauser FTI77-U1AEBRG111A1A Point level switch, capacitive. High temperature probe. Application: solids. Total length of probe L = L1+L3+ isolation ceramic. :: Start up via push button. :: Robust version. FTI77-PHJ4/0 Endress Hauser FTI77 U Approval: Non-hazardous area … [Read more...] about FTI77-U1AEBRG111A1A
FTL825-B23A4+LE
Endress + Hauser FTL825-B23A4+LE FailSafe level instrument point level. Top hat rail mounting. Connection to FTL80/FTL81/FTL85. :: SIL3 according to IEC61508. :: Permanent self-monitoring, LIVE-Signal. FTL825-10T5/0 Endress Hauser FTL825 B2 Approval: ATEX Ex ia G/D ATEX II (1)G … [Read more...] about FTL825-B23A4+LE
FTI77-Z1AEBRG111A1A
Endress + Hauser FTI77-Z1AEBRG111A1A … [Read more...] about FTI77-Z1AEBRG111A1A
FTL825-NR3A4
Endress + Hauser FTL825-NR3A4 FailSafe level instrument point level. Top hat rail mounting. Connection to FTL80/FTL81/FTL85. :: SIL3 according to IEC61508. :: Permanent self-monitoring, LIVE-Signal. FTL825-18U6/0 Endress Hauser FTL82 NR Approval: Non-hazardous area + China … [Read more...] about FTL825-NR3A4
FTI77-31AEBRG111A1A
Endress + Hauser FTI77-31AEBRG111A1A Point level switch, capacitive. High temperature probe. Application: solids. Total length of probe L = L1+L3+ isolation ceramic. :: Start up via push button. :: Robust version. FTI77-PHL5/0 Endress Hauser FTI77 3 Approval: NEPSI Ex ia/tb IIIC … [Read more...] about FTI77-31AEBRG111A1A
FTL825-8B3A4
Endress + Hauser FTL825-8B3A4 FailSafe level instrument point level. Top hat rail mounting. Connection to FTL80/FTL81/FTL85. :: SIL3 according to IEC61508. :: Permanent self-monitoring, LIVE-Signal. FTL825-10M7/0 Endress Hauser FTL825 8B Approval: ATEX/IECEx Ex ia G/D ATEX II … [Read more...] about FTL825-8B3A4
FTI77-41AEBRG111A1A
Endress + Hauser FTI77-41AEBRG111A1A Point level switch, capacitive. High temperature probe. Application: solids. Total length of probe L = L1+L3+ isolation ceramic. :: Start up via push button. :: Robust version. FTI77-PHM0/0 Endress Hauser FTI77 4 Approval: IECEx ia/tb IIIC … [Read more...] about FTI77-41AEBRG111A1A
FTL825-FB3A4
Endress + Hauser FTL825-FB3A4 FailSafe level instrument point level. Top hat rail mounting. Connection to FTL80/FTL81/FTL85. :: SIL3 according to IEC61508. :: Permanent self-monitoring, LIVE-Signal. FTL825-10D8/0 Endress Hauser FTL82 FB Approval: FM C/US AIS/ANI AIS Cl.I,II,III … [Read more...] about FTL825-FB3A4
FTI77-51AEBRG111A1A
Endress + Hauser FTI77-51AEBRG111A1A Point level switch, capacitive. High temperature probe. Application: solids. Total length of probe L = L1+L3+ isolation ceramic. :: Start up via push button. :: Robust version. FTI77-PHN6/0 Endress Hauser FTI77 5 Approval: IECEx ia/tc IIIC … [Read more...] about FTI77-51AEBRG111A1A
FTL825-B23E4
Endress + Hauser FTL825-B23E4 FailSafe level instrument point level. Top hat rail mounting. Connection to FTL80/FTL81/FTL85. :: SIL3 according to IEC61508. :: Permanent self-monitoring, LIVE-Signal. FTL825-1077/0 Endress Hauser FTL825 B2 Approval: ATEX Ex ia G/D ATEX II (1)G [Ex … [Read more...] about FTL825-B23E4
FTI77-A1BEBRG111A1A
Endress + Hauser FTI77-A1BEBRG111A1A Point level switch, capacitive. High temperature probe. Application: solids. Total length of probe L = L1+L3+ isolation ceramic. :: Start up via push button. :: Robust version. FTI77-PHP7/0 Endress Hauser FTI77 A Approval: Non-hazardous … [Read more...] about FTI77-A1BEBRG111A1A
FTL825-CB3E4
Endress + Hauser FTL825-CB3E4 FailSafe level instrument point level. Top hat rail mounting. Connection to FTL80/FTL81/FTL85. :: SIL3 according to IEC61508. :: Permanent self-monitoring, LIVE-Signal FTL825-10C2/0 Endress Hauser FTL825 CB Approval: CSA C/US AIS/ANI AIS Cl.I,II,III … [Read more...] about FTL825-CB3E4
FTI77-C1AEBRG111A1A
Endress + Hauser FTI77-C1AEBRG111A1A Point level switch, capacitive. High temperature probe. Application: solids. Total length of probe L = L1+L3+ isolation ceramic. :: Start up via push button. :: Robust version. FTI77-PHH3/0 Endress Hauser FTI77 C Approval: ATEX II 1/2D Ex … [Read more...] about FTI77-C1AEBRG111A1A
FTL825-B23A4
Endress + Hauser FTL825-B23A4 FailSafe level instrument point level. Top hat rail mounting. Connection to FTL80/FTL81/FTL85. :: SIL3 according to IEC61508. :: Permanent self-monitoring, LIVE-Signal. FTL825-1035/0 Endress Hauser FTL825 B2 Approval: ATEX Ex ia G/D ATEX II (1)G [Ex … [Read more...] about FTL825-B23A4
FTI56-CAA2BSJB1A1A
Endress + Hauser FTI56-CAA2BSJB1A1A Point level switch, capacitive. Rope probe. Application: powder, bulk solids. Total length of probe L = L1+L3. :: Start up via push button. :: Robust version. Endress Hauser FTI56 C Approval: ATEX II 1/2 D Ex ia/tb IIIC T90oC Da/Db A Inactive … [Read more...] about FTI56-CAA2BSJB1A1A
FTI77-U1BACRG111A1A
Endress + Hauser FTI77-U1BACRG111A1A Point level switch, capacitive. High temperature probe. Application: solids. Total length of probe L = L1+L3+ isolation ceramic. :: Start up via push button. :: Robust version. FTI77-PH86/0 Endress Hauser FTI77 U Approval: Non-hazardous area … [Read more...] about FTI77-U1BACRG111A1A
FTL825-N23A4
Endress + Hauser FTL825-N23A4 FailSafe level instrument point level. Top hat rail mounting. Connection to FTL80/FTL81/FTL85. :: SIL3 according to IEC61508. :: Permanent self-monitoring, LIVE-Signal. FTL825-10H0/0 Endress Hauser FTL825 N2 Approval: NEPSI Ex ia G/D NEPSI [Ex ia Ga] … [Read more...] about FTL825-N23A4
FTI56-AAA2BTJB1A1A
Endress + Hauser FTI56-AAA2BTJB1A1A Point level switch, capacitive. Rope probe. Application: powder, bulk solids. Total length of probe L = L1+L3. :: Start up via push button. :: Robust version. Endress Hauser FTI56 A Approval: Non-hazardous area A Inactive Length L3: Not … [Read more...] about FTI56-AAA2BTJB1A1A
FTI77-C1AABRG111A1A
Endress + Hauser FTI77-C1AABRG111A1A Point level switch, capacitive. High temperature probe. Application: solids. Total length of probe L = L1+L3+ isolation ceramic. :: Start up via push button. :: Robust version. FTI77-PFN9/0 Endress Hauser FTI77 C Approval: ATEX II 1/2D Ex … [Read more...] about FTI77-C1AABRG111A1A
FTL825-GR3A4
Endress + Hauser FTL825-GR3A4 FailSafe level instrument point level. Top hat rail mounting. Connection to FTL80/FTL81/FTL85. :: SIL3 according to IEC61508. :: Permanent self-monitoring, LIVE-Signal FTL825-1571/0 Endress Hauser FTL825 GR Approval: Non-hazardous area + EAC … [Read more...] about FTL825-GR3A4
FTI56-AAA2KGJB1A1A
Endress + Hauser FTI56-AAA2KGJB1A1A Point level switch, capacitive. Rope probe. Application: powder, bulk solids. Total length of probe L = L1+L3. :: Start up via push button. :: Robust version. Endress Hauser FTI56 A Approval: Non-hazardous area A Inactive Length L3: Not … [Read more...] about FTI56-AAA2KGJB1A1A
FTI77-B1BACRG111A1A
Endress + Hauser FTI77-B1BACRG111A1A Point level switch, capacitive. High temperature probe. Application: solids. Total length of probe L = L1+L3+ isolation ceramic. :: Start up via push button. :: Robust version. FTI77-ECA5/0 Endress Hauser FTI77 B Approval: ATEX II 1/3D Ex … [Read more...] about FTI77-B1BACRG111A1A
FTL825-8C3A4
Endress + Hauser FTL825-8C3A4 FailSafe level instrument point level. Top hat rail mounting. Connection to FTL80/FTL81/FTL85. :: SIL3 according to IEC61508. :: Permanent self-monitoring, LIVE-Signal. FTL825-10P3/0 Endress Hauser FTL82 8C Approval: FM/CSA C/US AIS/ANI AIS … [Read more...] about FTL825-8C3A4
FTI56-CAA2BTJB1A1A
Endress + Hauser FTI56-CAA2BTJB1A1A Point level switch, capacitive. Rope probe. Application: powder, bulk solids. Total length of probe L = L1+L3. :: Start up via push button. :: Robust version. Endress Hauser FTI56 C Approval: ATEX II 1/2 D Ex ia/tb IIIC T90oC Da/Db A Inactive … [Read more...] about FTI56-CAA2BTJB1A1A
FTI77-U1AABRG111A1A
Endress + Hauser FTI77-U1AABRG111A1A Point level switch, capacitive. High temperature probe. Application: solids. Total length of probe L = L1+L3+ isolation ceramic. :: Start up via push button. :: Robust version. FTI77-PFP0/0 Endress Hauser FTI77 U Approval: Non-hazardous area … [Read more...] about FTI77-U1AABRG111A1A
FTI56-CAA2AHJB1A1A
Endress + Hauser FTI56-CAA2AHJB1A1A Point level switch, capacitive. Rope probe. Application: powder, bulk solids. Total length of probe L = L1+L3. :: Start up via push button. :: Robust version. Endress Hauser FTI56 C Approval: ATEX II 1/2 D Ex ia/tb IIIC T90oC Da/Db A Inactive … [Read more...] about FTI56-CAA2AHJB1A1A
FTI77-A1BACRG111A1A
Endress + Hauser FTI77-A1BACRG111A1A Point level switch, capacitive. High temperature probe. Application: solids. Total length of probe L = L1+L3+ isolation ceramic. :: Start up via push button. :: Robust version. FTI77-9AD0/0 Endress Hauser FTI77 A Approval: Non-hazardous … [Read more...] about FTI77-A1BACRG111A1A
FTL825-AA3A4+LCPAZ1
Endress + Hauser FTL825-AA3A4+LCPAZ1 FailSafe level instrument point level. Top hat rail mounting. Connection to FTL80/FTL81/FTL85. :: SIL3 according to IEC61508. :: Permanent self-monitoring, LIVE-Signal. FTL825-17H1/0 Endress Hauser FTL825 AA Approval: Non-hazardous area … [Read more...] about FTL825-AA3A4+LCPAZ1
FTL825-N23E4+PA
Endress + Hauser FTL825-N23E4+PA FailSafe level instrument point level. Top hat rail mounting. Connection to FTL80/FTL81/FTL85. :: SIL3 according to IEC61508. :: Permanent self-monitoring, LIVE-Signal. FTL825-1A50/0 Endress Hauser FTL825 N2 Approval: NEPSI Ex ia G/D NEPSI [Ex ia … [Read more...] about FTL825-N23E4+PA