Endress + Hauser ultrasonic sensor for level and flow measurement Prosonic FDU91

Endress + Hauser ultrasonic sensor for level and flow measurement Prosonic FDU91

Endress + Hauser sensor Prosonic FDU91 for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials, for connection to FMU9x (measuring range up to 10m).

Endress + Hauser sensor Prosonic FDU91 characteristic:

Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter.

Endress + Hauser sensor Prosonic FDU91 Supply / Communication:

4-wire (HART, Profibus DP)

Endress + Hauser sensor Prosonic FDU91 Accuracy:

+/- 2 mm + 0.17% of measured distance

Endress + Hauser sensor Prosonic FDU91 Ambient + process temperature:

-40 °C ... 80 °C (-40 °F ... 176 °F)

Endress + Hauser sensor Prosonic FDU91 Process pressure absolute / max. overpressure limit:

0.7 bar ... 4 bar abs (10 psi ... 58 psi)

Endress + Hauser ultrasonic sensor for level and flow measurement Prosonic FDU91 application:

E+H Prosonic FDU91 sensor for continuous, non-contact level measurement of fluids and of bulk materials in silos, on belts, stockpiles and in crushers. Also for flow measurement in open channels and at weirs. Typically used in measurements in low structural heights.
• Process connection: Thread
• Temperature: -40 to +80°C (-40 to +176°F)
• Pressure: +0.7 to +4bar (+10 to +58psi)
• Maximum measuring range: Liquids 10m (33ft), solids 5m (16ft)
• Blocking distance: 0.3m (1ft)
• International explosion protection certificates

Endress + Hauser sensor Prosonic FDU91 advantages are:

• Integrated temperature sensor for Time-of-Flight correction. Accurate measurements are possible, even if temperature changes are present
• Hermetically welded PVDF sensor for highest chemical resistance
• Suited for rough ambient conditions thanks to separate installation from the transmitter (up to 300m)
• Reduced build-up formation because of the self-cleaning effect
• Integrated automatic sensor detection for transmitters FMU90/FMU95 for simple commissioning
• Weather resistant and flood-proof (IP 68)
• Integrated heating against a build-up of ice at the sensor (optional) ensures reliable measurement

FDU91-FN3AA

© E+H Ultrasonic sensor for level and flow FDU91-FN3AA

Endress + Hauser FDU91-FN3AA Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-FN3AA

FDU91-EG2BL

© E+H Ultrasonic sensor for level and flow FDU91-EG2BL

Endress + Hauser FDU91-EG2BL Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-EG2BL

FDU91-DG2AA

© E+H Ultrasonic sensor for level and flow FDU91-DG2AA

Endress + Hauser FDU91-DG2AA Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-DG2AA

FDU91-HG2AM

© E+H Ultrasonic sensor for level and flow FDU91-HG2AM

Endress + Hauser FDU91-HG2AM Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-HG2AM

FDU91-MG1BA

© E+H Ultrasonic sensor for level and flow FDU91-MG1BA

Endress + Hauser FDU91-MG1BA Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-MG1BA

FDU91-JG2AM

Endress + Hauser FDU91-JG2AM Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-JG2AM

FDU91-CN5BA

© E+H Ultrasonic sensor for level and flow FDU91-CN5BA

Endress + Hauser FDU91-CN5BA Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-CN5BA

FDU91-MN3AA

© E+H Ultrasonic sensor for level and flow FDU91-MN3AA

Endress + Hauser FDU91-MN3AA Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-MN3AA

FDU91-DG2BM

© E+H Ultrasonic sensor for level and flow FDU91-DG2BM

Endress + Hauser FDU91-DG2BM Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-DG2BM

FDU91-RG1AL

© E+H Ultrasonic sensor for level and flow FDU91-RG1AL

Endress + Hauser FDU91-RG1AL Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-RG1AL

FDU91-CG2AA

© E+H Ultrasonic sensor for level and flow FDU91-CG2AA

Endress + Hauser FDU91-CG2AA Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-CG2AA

FDU91-EN5BA

© E+H Ultrasonic sensor for level and flow FDU91-EN5BA

Endress + Hauser FDU91-EN5BA Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-EN5BA

FDU91-GN4BL

© E+H Ultrasonic sensor for level and flow FDU91-GN4BL

Endress + Hauser FDU91-GN4BL Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-GN4BL

FDU91-DN5BA

© E+H Ultrasonic sensor for level and flow FDU91-DN5BA

Endress + Hauser FDU91-DN5BA Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-DN5BA

FDU91-KN3AA

© E+H Ultrasonic sensor for level and flow FDU91-KN3AA

Endress + Hauser FDU91-KN3AA Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-KN3AA

FDU91-HG1AA

© E+H Ultrasonic sensor for level and flow FDU91-HG1AA

Endress + Hauser FDU91-HG1AA Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-HG1AA

FDU91-GN5BA

© E+H Ultrasonic sensor for level and flow FDU91-GN5BA

Endress + Hauser FDU91-GN5BA Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-GN5BA

FDU91-JG2AM

© E+H Ultrasonic sensor for level and flow FDU91-JG2AM

Endress + Hauser FDU91-JG2AM Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-JG2AM

FDU91-RG2AM

© E+H Ultrasonic sensor for level and flow FDU91-RG2AM

Endress + Hauser FDU91-RG2AM Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-RG2AM

FDU91-KG2AM

© E+H Ultrasonic sensor for level and flow FDU91-KG2AM

Endress + Hauser FDU91-KG2AM Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-KG2AM

FDU91-FN6AM

© E+H Ultrasonic sensor for level and flow FDU91-FN6AM

Endress + Hauser FDU91-FN6AM Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-FN6AM

FDU91-JG1AL

© E+H Ultrasonic sensor for level and flow FDU91-JG1AL

Endress + Hauser FDU91-JG1AL Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-JG1AL

FDU91-FG1AL

© E+H Ultrasonic sensor for level and flow FDU91-FG1AL

Endress + Hauser FDU91-FG1AL Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-FG1AL

FDU91-KN6AM

© E+H Ultrasonic sensor for level and flow FDU91-KN6AM

Endress + Hauser FDU91-KN6AM Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-KN6AM

FDU91-RN3AA

© E+H Ultrasonic sensor for level and flow FDU91-RN3AA

Endress + Hauser FDU91-RN3AA Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-RN3AA

FDU91-CN4BL

© E+H Ultrasonic sensor for level and flow FDU91-CN4BL

Endress + Hauser FDU91-CN4BL Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-CN4BL

FDU91-DN4BL

© E+H Ultrasonic sensor for level and flow FDU91-DN4BL

Endress + Hauser FDU91-DN4BL Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-DN4BL

FDU91-GG2BM

© E+H Ultrasonic sensor for level and flow FDU91-GG2BM

Endress + Hauser FDU91-GG2BM Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-GG2BM

FDU91-FG2AM

© E+H Ultrasonic sensor for level and flow FDU91-FG2AM

Endress + Hauser FDU91-FG2AM Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-FG2AM

FDU91-MG1AL

© E+H Ultrasonic sensor for level and flow FDU91-MG1AL

Endress + Hauser FDU91-MG1AL Level, ultrasonic, contactless Sensor for connection to FMU90/FMU95 Application: liquids, solids Sensor: PVDF Measuring range: 10m/32ft (liquid) 5m/16ft (solid) Max -40...80oC/176oF Max 4bar/60psi abs. Blocking distance: 30cm/1ft :: High … [Read more...] about FDU91-MG1AL

  • Go to page 1
  • Go to page 2
  • Go to Next Page »

Primary Sidebar

Contact us:





    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • CPS41E-IA7BSC2
    • FDU95-E2G3A
    • FTL70-DAE6AE7E7NN
    • FTL50-DBB2QA4F7D
    • FTL50-SBD2AADE1C
    • CPS96E-BA7BTH5
    • CPS41E-MA7BSB4
    • FDU95-H1G1A
    • FTL70-NAE6AE6E8AL
    • FTL50-SBA2IA7E5A
    • FTL50-WAL2AA4G5D
    • CPS96E-UR7BTH6+Z1
    • Fristam 0810610010 SLIDE RING D=22 FOR HR7/22 TUNGSTEN CARBIDE
    • CPS41E-IA7BSB5
    • FTL70-AAE6AEAF1CL
    • FTL50-IBB2QA4F7D
    • CPS96E-KA7BTH5+Z1
    • Fristam 0817310036 Spare mechanical seal 729a 2L 5P
    • CPS41E-GR7BSB5
    • FDU95-D1G6A

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2023 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.