Endress + Hauser 10D40-4CGA1AA0AXXX Electromagnetic flowmeter 4 Liner: Polyamide, NSF 61 Drinking- + warm water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: w/o A Approval: … [Read more...] about 10D40-4CGA1AA0AXXX
Endress + Hauser Proline Promag 10D electromagnetic flowmeter basic unit for non spacious application in water industry
Endress + Hauser Proline Promag 10D electromagnetic flowmeter basic unit for non spacious application in water industry. Highly cost-effective flowmeter, available as compact wafer. Easy and fast centering of the sensor – innovative housing construction. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction.
Endress + Hauser Proline Promag 10D electromagnetic flowmeter measuring principle:
Electromagnetic
Endress + Hauser Proline Promag 10D electromagnetic flowmeter measured values:
Volume flow
Endress + Hauser Proline Promag 10D electromagnetic flowmeter measuring range:
9 to 4700 dm3/min (2.5 to 1250 gal/min)
Endress + Hauser Proline Promag 10D electromagnetic flowmeter nominal diameter range:
DN 25 to 100 (1 to 4")
Endress + Hauser Proline Promag 10D electromagnetic flowmeter application:
• The measuring principle is virtually independent of pressure, density, temperature and viscosity
• For basic water applications; optimized for limited space and plastic pipe installations.
Device properties
• Short installation length and low weight
• Integrated ground disks made of stainless steel
• International drinking water approvals
• 2‐line display with push buttons
• Device in compact or remote version
• HART
Endress + Hauser Proline Promag 10D electromagnetic flowmeter advantages are:
• Easy, fast centering of the sensor – innovative housing construction
• Energy-saving flow measurement – no pressure loss due to cross-section constriction
• Cost-effective – designed for easy applications and direct integration
• Safe operation – display provides easy readable process information
• Fully industry compliant – IEC/EN/NAMUR
• Maintenance-free – no moving parts
Endress + Hauser Proline Promag 10D electromagnetic flowmeter medium process temperature:
0 to +60 °C (+32 to +140 °F)
Endress + Hauser Proline Promag 10D electromagnetic flowmeter ambient temperature:
–20 to +60 °C (–4 to +140 °F)
Endress + Hauser Proline Promag 10D electromagnetic flowmeter process pressure:
PN 16, Class 150, 10K
Endress + Hauser Proline Promag 10D electromagnetic flowmeter power supply:
DC 11 to 40 V
AC 85 to 250 V (45 to 65 Hz)
AC 20 to 28 V (45 to 65 Hz)
Endress + Hauser Proline Promag 10D electromagnetic flowmeter outputs:
• 4‐20 mA HART (active)
• Pulse/switch output (passive)
10D40-6UGA1AA0AXXX
Endress + Hauser 10D40-6UGA1AA0AXXX Electromagnetic flowmeter 6 Liner: Polyamide, ACS Drinking water approval U Process Connection: Threaded G, 1.4404/316L DN25/G1”, DN40/G1 1/2”, DN50/G2” G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: … [Read more...] about 10D40-6UGA1AA0AXXX
10D40-3VGA1AA0AXXX
Endress + Hauser 10D40-3VGA1AA0AXXX Electromagnetic flowmeter 3 Liner: Polyamide V Process Connection: Threaded NPT, 1.4404/316L DN25/NPT 1”, DN40/NPT 1 1/2”, DN50/NPT2” G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: w/o A Approval: … [Read more...] about 10D40-3VGA1AA0AXXX
10D40-4VGAEAA0AXXX
Endress + Hauser 10D40-4VGAEAA0AXXX Electromagnetic flowmeter 4 Liner: Polyamide, NSF 61 Drinking- + warm water approval V Process Connection: Threaded NPT, 1.4404/316L DN25/NPT 1”, DN40/NPT 1 1/2”, DN50/NPT2” G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% E Additional … [Read more...] about 10D40-4VGAEAA0AXXX
10D40-7UGA1AA0AXXX
Endress + Hauser 10D40-7UGA1AA0AXXX Electromagnetic flowmeter 7 Liner: Polyamide, WRAS BS6920 Drinking water approval U Process Connection: Threaded G, 1.4404/316L DN25/G1”, DN40/G1 1/2”, DN50/G2” G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, … [Read more...] about 10D40-7UGA1AA0AXXX
10D40-5TGAEAA0AXXX
Endress + Hauser 10D40-5TGAEAA0AXXX Electromagnetic flowmeter 5 Liner: Polyamide, KTW/W270 Drinking water approval T Process Connection: 10K, JIS B2220 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% E Additional Test, certificate: EAC marking A Approval: Non-hazardous … [Read more...] about 10D40-5TGAEAA0AXXX
10D40-7TGA1AA0AXXX
Endress + Hauser 10D40-7TGA1AA0AXXX Electromagnetic flowmeter 7 Liner: Polyamide, WRAS BS6920 Drinking water approval T Process Connection: 10K, JIS B2220 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: w/o A Approval: Non-hazardous area … [Read more...] about 10D40-7TGA1AA0AXXX
10D40-6TGA1AA0AXXX
Endress + Hauser 10D40-6TGA1AA0AXXX Electromagnetic flowmeter 6 Liner: Polyamide, ACS Drinking water approval T Process Connection: 10K, JIS B2220 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: w/o A Approval: Non-hazardous area … [Read more...] about 10D40-6TGA1AA0AXXX
10D40-5UGA1AA0AXXX
Endress + Hauser 10D40-5UGA1AA0AXXX Electromagnetic flowmeter 5 Liner: Polyamide, KTW/W270 Drinking water approval U Process Connection: Threaded G, 1.4404/316L DN25/G1”, DN40/G1 1/2”, DN50/G2” G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: … [Read more...] about 10D40-5UGA1AA0AXXX
10D40-5LGAEAA0AXXX
Endress + Hauser 10D40-5LGAEAA0AXXX Electromagnetic flowmeter 5 Liner: Polyamide, KTW/W270 Drinking water approval L Process Connection: Cl.150 ANSI B16.5 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% E Additional Test, certificate: EAC marking A Approval: … [Read more...] about 10D40-5LGAEAA0AXXX
10D40-3UGA1AA0AXXX
Endress + Hauser 10D40-3UGA1AA0AXXX Electromagnetic flowmeter 3 Liner: Polyamide U Process Connection: Threaded G, 1.4404/316L DN25/G1”, DN40/G1 1/2”, DN50/G2” G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: w/o A Approval: Non-hazardous … [Read more...] about 10D40-3UGA1AA0AXXX
10D40-3LGA1AA0AXXX
Endress + Hauser 10D40-3LGA1AA0AXXX Electromagnetic flowmeter 3 Liner: Polyamide L Process Connection: Cl.150 ANSI B16.5 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: w/o A Approval: Non-hazardous area A Housing: Compact Alu, IP67 … [Read more...] about 10D40-3LGA1AA0AXXX
10D40-3TGAEAA0AXXX
Endress + Hauser 10D40-3TGAEAA0AXXX Electromagnetic flowmeter 3 Liner: Polyamide T Process Connection: 10K, JIS B2220 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% E Additional Test, certificate: EAC marking A Approval: Non-hazardous area A Housing: Compact Alu, IP67 … [Read more...] about 10D40-3TGAEAA0AXXX
10D40-7CGA1AA0AXXX
Endress + Hauser 10D40-7CGA1AA0AXXX Electromagnetic flowmeter 7 Liner: Polyamide, WRAS BS6920 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: w/o A Approval: … [Read more...] about 10D40-7CGA1AA0AXXX
10D40-3CGA1AA0AXXX
Endress + Hauser 10D40-3CGA1AA0AXXX Electromagnetic flowmeter 3 Liner: Polyamide C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: w/o A Approval: Non-hazardous area A Housing: Compact Alu, … [Read more...] about 10D40-3CGA1AA0AXXX
10D40-5VGAEAA0AXXX
Endress + Hauser 10D40-5VGAEAA0AXXX Electromagnetic flowmeter 5 Liner: Polyamide, KTW/W270 Drinking water approval V Process Connection: Threaded NPT, 1.4404/316L DN25/NPT 1”, DN40/NPT 1 1/2”, DN50/NPT2” G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% E Additional Test, … [Read more...] about 10D40-5VGAEAA0AXXX
10D40-5TGA1AA0AXXX
Endress + Hauser 10D40-5TGA1AA0AXXX Electromagnetic flowmeter 5 Liner: Polyamide, KTW/W270 Drinking water approval T Process Connection: 10K, JIS B2220 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: w/o A Approval: Non-hazardous area … [Read more...] about 10D40-5TGA1AA0AXXX
10D40-4UGA1AA0AXXX
Endress + Hauser 10D40-4UGA1AA0AXXX Electromagnetic flowmeter 4 Liner: Polyamide, NSF 61 Drinking- + warm water approval U Process Connection: Threaded G, 1.4404/316L DN25/G1”, DN40/G1 1/2”, DN50/G2” G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, … [Read more...] about 10D40-4UGA1AA0AXXX
10D40-6TGAEAA0AXXX
Endress + Hauser 10D40-6TGAEAA0AXXX Electromagnetic flowmeter 6 Liner: Polyamide, ACS Drinking water approval T Process Connection: 10K, JIS B2220 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% E Additional Test, certificate: EAC marking A Approval: Non-hazardous area … [Read more...] about 10D40-6TGAEAA0AXXX
10D40-5LGA1AA0AXXX
Endress + Hauser 10D40-5LGA1AA0AXXX Electromagnetic flowmeter 5 Liner: Polyamide, KTW/W270 Drinking water approval L Process Connection: Cl.150 ANSI B16.5 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: w/o A Approval: Non-hazardous area … [Read more...] about 10D40-5LGA1AA0AXXX
10D40-6UGAEAA0AXXX
Endress + Hauser 10D40-6UGAEAA0AXXX Electromagnetic flowmeter 6 Liner: Polyamide, ACS Drinking water approval U Process Connection: Threaded G, 1.4404/316L DN25/G1”, DN40/G1 1/2”, DN50/G2” G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% E Additional Test, certificate: EAC … [Read more...] about 10D40-6UGAEAA0AXXX
10D25-3TGA1AA0A0BA
Endress + Hauser 10D25-3TGA1AA0A0BA Electromagnetic flowmeter 3 Liner: Polyamide T Process Connection: 10K, JIS B2220 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: w/o A Approval: Non-hazardous area A Housing: Compact Alu, IP67 … [Read more...] about 10D25-3TGA1AA0A0BA
10D25-6VGAEAA0A0BA
Endress + Hauser 10D25-6VGAEAA0A0BA Electromagnetic flowmeter 6 Liner: Polyamide, ACS Drinking water approval V Process Connection: Threaded NPT, 1.4404/316L DN25/NPT 1”, DN40/NPT 1 1/2”, DN50/NPT2” G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% E Additional Test, … [Read more...] about 10D25-6VGAEAA0A0BA
10D25-7LGA1AA0A0BA
Endress + Hauser 10D25-7LGA1AA0A0BA Electromagnetic flowmeter 7 Liner: Polyamide, WRAS BS6920 Drinking water approval L Process Connection: Cl.150 ANSI B16.5 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: w/o A Approval: Non-hazardous … [Read more...] about 10D25-7LGA1AA0A0BA
10D25-3UGAEAA0A0BA
Endress + Hauser 10D25-3UGAEAA0A0BA Electromagnetic flowmeter 3 Liner: Polyamide U Process Connection: Threaded G, 1.4404/316L DN25/G1”, DN40/G1 1/2”, DN50/G2” G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% E Additional Test, certificate: EAC marking A Approval: … [Read more...] about 10D25-3UGAEAA0A0BA
10D25-7LGAEAA0A0BA
Endress + Hauser 10D25-7LGAEAA0A0BA Electromagnetic flowmeter 7 Liner: Polyamide, WRAS BS6920 Drinking water approval L Process Connection: Cl.150 ANSI B16.5 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% E Additional Test, certificate: EAC marking A Approval: … [Read more...] about 10D25-7LGAEAA0A0BA
10D25-4TGA1AA0A0BA
Endress + Hauser 10D25-4TGA1AA0A0BA Electromagnetic flowmeter 4 Liner: Polyamide, NSF 61 Drinking- + warm water approval T Process Connection: 10K, JIS B2220 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: w/o A Approval: Non-hazardous … [Read more...] about 10D25-4TGA1AA0A0BA
10D25-4TGAEAA0A0BA
Endress + Hauser 10D25-4TGAEAA0A0BA Electromagnetic flowmeter 4 Liner: Polyamide, NSF 61 Drinking- + warm water approval T Process Connection: 10K, JIS B2220 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% E Additional Test, certificate: EAC marking A Approval: … [Read more...] about 10D25-4TGAEAA0A0BA
10D25-5TGA1AA0A0BA
Endress + Hauser 10D25-5TGA1AA0A0BA Electromagnetic flowmeter 5 Liner: Polyamide, KTW/W270 Drinking water approval T Process Connection: 10K, JIS B2220 G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% 1 Additional Test, certificate: w/o A Approval: Non-hazardous area … [Read more...] about 10D25-5TGA1AA0A0BA
10D25-4UGAEAA0A0BA
Endress + Hauser 10D25-4UGAEAA0A0BA Electromagnetic flowmeter 4 Liner: Polyamide, NSF 61 Drinking- + warm water approval U Process Connection: Threaded G, 1.4404/316L DN25/G1”, DN40/G1 1/2”, DN50/G2” G Electrodes: 1.4435/316L bullet nose A Calibration: 0.5% E Additional Test, … [Read more...] about 10D25-4UGAEAA0A0BA