Home / Endress+Hauser / E+H Analytics / Process analytical technology pharmaceutical industry / OUSAF44

Endress + Hauser OUSAF44 UV absorption sensor monitoring product concentration with ATEX and FM approvals

ENDRESS + HAUSER UV absorption sensor OUSAF44

UV absorption sensor OUSAF44 monitors the concentration of your product in process liquids. Its outstanding filter performance ensures highest linearity and full consistency with lab results.
Measurement of protein concentrations, chromatography monitoring, filtration monitoring, concentration measurement of organic compounds, detection of aromates. Sensor for installation in the pipe with separate flow assembly OUA260.

OUSAF44 measured value

  • UV-absorption

OUSAF44 measuring range

• 0 to 2.5 AU
• Max. 50 OD (depending on the optical path length)

OUSAF44 wavelength

Discrete wavelength at 254, 280, 295, 302, 313 or 365 nm
More available on request

OUSAF44 application

The OUSAF44 sensor measures the UV absorption for:
• Measurement of protein concentrations
• Chromatography control
• Permeate and retentate monitoring
• Concentration measurement of organic compounds
• Aromatics detection
• Filter monitoring
with international explosion-protection approvals, such as ATEX and FM, the sensor is suitable for hazardous area use.

OUSAF44 advantages

• Fast and reliable monitoring of product concentration for better process control and simplified quality control
• Precise measured values with full consistency to laboratory results
• Patented EasycalTM system option for easy, liquid-free online calibration traceable to NIST
• Low-maintenance sensor with long service life and stable operation
• Outstanding filter performance provides highest linearity
• Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)
• Approved for hazardous area use

OUSAF44 process temperature

0 to 90 °C (32 to 194 °F) continuous
Max. 130 °C (266 °F) for 2 hours

OUSAF44 process pressure

Max. 100 bar (1450 psi) absolute, depending on the material, pipe size and process connection of the flow assembly

OUSAF44-C1A0

© E+H UV absorbance sensor OUSAF44-C1A0

Endress + Hauser OUSAF44-C1A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 C Wavelength: 295 nm 1 Calibration/Validation: Easycal A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-C1A0

OUSAF44-B1A0

© E+H UV absorbance sensor OUSAF44-B1A0

Endress + Hauser OUSAF44-B1A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 B Wavelength: 280 nm 1 Calibration/Validation: Easycal A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-B1A0

OUSAF44-F0B0

© E+H UV absorbance sensor OUSAF44-F0B0

Endress + Hauser OUSAF44-F0B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 F Wavelength: 365 nm 0 Calibration/Validation: Standard B Lamp Approval: FM XP Cl. I Div. … [Read more...] about OUSAF44-F0B0

OUSAF44-C1C0

© E+H UV absorbance sensor OUSAF44-C1C0

Endress + Hauser OUSAF44-C1C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 C Wavelength: 295 nm 1 Calibration/Validation: Easycal C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-C1C0

OUSAF44-E0B0

© E+H UV absorbance sensor OUSAF44-E0B0

Endress + Hauser OUSAF44-E0B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 E Wavelength: 313 nm 0 Calibration/Validation: Standard B Lamp Approval: FM XP Cl. I Div. … [Read more...] about OUSAF44-E0B0

OUSAF44-A0C0

© E+H UV absorbance sensor OUSAF44-A0C0

Endress + Hauser OUSAF44-A0C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 A Wavelength: 254 nm 0 Calibration/Validation: Standard C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-A0C0

OUSAF44-B0A0

© E+H UV absorbance sensor OUSAF44-B0A0

Endress + Hauser OUSAF44-B0A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 B Wavelength: 280 nm 0 Calibration/Validation: Standard A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-B0A0

OUSAF44-B1B0

© E+H UV absorbance sensor OUSAF44-B1B0

Endress + Hauser OUSAF44-B1B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 B Wavelength: 280 nm 1 Calibration/Validation: Easycal B Lamp Approval: FM XP Cl. I Div. 1 … [Read more...] about OUSAF44-B1B0

OUSAF44-C0B0

© E+H UV absorbance sensor OUSAF44-C0B0

Endress + Hauser OUSAF44-C0B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 C Wavelength: 295 nm 0 Calibration/Validation: Standard B Lamp Approval: FM XP Cl. I Div. … [Read more...] about OUSAF44-C0B0

OUSAF44-D1A0

© E+H UV absorbance sensor OUSAF44-D1A0

Endress + Hauser OUSAF44-D1A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 D Wavelength: 302 nm 1 Calibration/Validation: Easycal A Lamp Approval: Non-hazardous area … [Read more...] about OUSAF44-D1A0

OUSAF44-A1A0

© E+H UV absorbance sensor OUSAF44-A1A0

Endress + Hauser OUSAF44-A1A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 A Wavelength: 254 nm 1 Calibration/Validation: Easycal A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-A1A0

OUSAF44-B0C0

© E+H UV absorbance sensor OUSAF44-B0C0

Endress + Hauser OUSAF44-B0C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 B Wavelength: 280 nm 0 Calibration/Validation: Standard C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-B0C0

OUSAF44-F1B0

© E+H UV absorbance sensor OUSAF44-F1B0

Endress + Hauser OUSAF44-F1B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 F Wavelength: 365 nm 1 Calibration/Validation: Easycal B Lamp Approval: FM XP Cl. I Div. 1 … [Read more...] about OUSAF44-F1B0

OUSAF44-B0B0

© E+H UV absorbance sensor OUSAF44-B0B0

Endress + Hauser OUSAF44-B0B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress + Hauser OUSAF44-B0B0 B Wavelength: 280 nm 0 Calibration/Validation: Standard B Lamp Approval: FM XP Cl. … [Read more...] about OUSAF44-B0B0

OUSAF44-F0C0

© E+H UV absorbance sensor OUSAF44-F0C0

Endress + Hauser OUSAF44-F0C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 F Wavelength: 365 nm 0 Calibration/Validation: Standard C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-F0C0

OUSAF44-A1B0

© E+H UV absorbance sensor OUSAF44-A1B0

Endress + Hauser OUSAF44-A1B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 A Wavelength: 254 nm 1 Calibration/Validation: Easycal B Lamp Approval: FM XP Cl. I Div. 1 … [Read more...] about OUSAF44-A1B0

OUSAF44-A0A0

© E+H UV absorbance sensor OUSAF44-A0A0

Endress + Hauser OUSAF44-A0A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 A Wavelength: 254 nm 0 Calibration/Validation: Standard A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-A0A0

OUSAF44-D1C0

© E+H UV absorbance sensor OUSAF44-D1C0

Endress + Hauser OUSAF44-D1C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on … [Read more...] about OUSAF44-D1C0

OUSAF44-A1C0

© E+H UV absorbance sensor OUSAF44-A1C0

Endress + Hauser OUSAF44-A1C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 A Wavelength: 254 nm 1 Calibration/Validation: Easycal C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-A1C0

OUSAF44-E0C0

© E+H UV absorbance sensor OUSAF44-E0C0

Endress + Hauser OUSAF44-E0C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 E Wavelength: 313 nm 0 Calibration/Validation: Standard C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-E0C0

OUSAF44-F0A0

© E+H UV absorbance sensor OUSAF44-F0A0

Endress + Hauser OUSAF44-F0A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress + Hauser OUSAF44-F0A0 F Wavelength: 365 nm 0 Calibration/Validation: Standard A Lamp Approval: … [Read more...] about OUSAF44-F0A0

OUSAF44-B1C0

© E+H UV absorbance sensor OUSAF44-B1C0

Endress + Hauser OUSAF44-B1C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 B Wavelength: 280 nm 1 Calibration/Validation: Easycal C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-B1C0

OUSAF44-C0A0

© E+H UV absorbance sensor OUSAF44-C0A0

Endress + Hauser OUSAF44-C0A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 C Wavelength: 295 nm 0 Calibration/Validation: Standard A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-C0A0

OUSAF44-E1B0

© E+H UV absorbance sensor OUSAF44-E1B0

Endress + Hauser OUSAF44-E1B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 E Wavelength: 313 nm 1 Calibration/Validation: Easycal B Lamp Approval: FM XP Cl. I Div. 1 … [Read more...] about OUSAF44-E1B0

OUSAF44-E1C0

© E+H UV absorbance sensor OUSAF44-E1C0

Endress + Hauser OUSAF44-E1C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 E Wavelength: 313 nm 1 Calibration/Validation: Easycal C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-E1C0

OUSAF44-F1C0

© E+H UV absorbance sensor OUSAF44-F1C0

Endress + Hauser OUSAF44-F1C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 F Wavelength: 365 nm 1 Calibration/Validation: Easycal C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-F1C0

OUSAF44-D0C0

© E+H UV absorbance sensor OUSAF44-D0C0

Endress + Hauser OUSAF44-D0C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 D Wavelength: 302 nm 0 Calibration/Validation: Standard C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-D0C0

OUSAF44-C0C0

© E+H UV absorbance sensor OUSAF44-C0C0

Endress + Hauser OUSAF44-C0C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 C Wavelength: 295 nm 0 Calibration/Validation: Standard C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-C0C0

OUSAF44-F1A0

© E+H UV absorbance sensor OUSAF44-F1A0

Endress + Hauser OUSAF44-F1A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 F Wavelength: 365 nm 1 Calibration/Validation: Easycal A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-F1A0

OUSAF44-C1B0

© E+H UV absorbance sensor OUSAF44-C1B0

Endress + Hauser OUSAF44-C1B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 C Wavelength: 295 nm 1 Calibration/Validation: Easycal B Lamp Approval: FM XP Cl. I Div. 1 … [Read more...] about OUSAF44-C1B0

  • Page 1
  • Page 2
  • Go to Next Page »

Primary Sidebar

Contact us:





    What is 1 + 4

    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • TM131-U4AAAFA2AA3AAAB0AA1AA1
    • TM131-URAAAFA2AA3AAAB0AA1AA1
    • TM131-U5AAAFA2AA3AAAB0AA1AA1
    • TM131-8FAAAFA2AA3AAAB0AA1AA1
    • TM131-URAAAFA2AA2AAAB0AA1AA1
    • TM131-U4AAAFA2AA2AAAB0AA1AA1
    • TM131-8FAAAFA1AA3AAAB0AA1AA1
    • TM131-AAAAAFA1AA4AAAB0AA1AA1
    • TM131-G4AAAFA1AA8AAAB0AA1AA1
    • TM131-84AAAFA2AA2AAAB0AA1AA1
    • TM131-CGAAAFA2AA3AAAB0AA1AA1
    • TM131-GFAAAFA2AA3AAAB0AA1AA1
    • TM121-GRHBB1A6BC1A3A1
    • TM131-GJAAAFA1AA5AAAB0AA1AA1
    • TM131-MAAAAFA1AA8AAAB0AA1AA1
    • TM121-AAACB1A4BA1A3A1
    • TM111-MAAABA1BBB0AA1AA1
    • TM111-U5ABAA1BBB0AA1AA1
    • TM121-URA4BA1A3A1
    • TM131-NFAAAFA1AA4AAAB0AA1AA1

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2025 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.