Endress + Hauser OUSAF11 NIR/VIS glass-free absorption sensor for inline detection of suspended solids and changing phases

ENDRESS + HAUSER NIR/VIS glass-free absorption sensor OUSAF11

E+H OUSAF11 is a glass-free sensor for the inline detection of changing phases and suspended solids. Insert it in pipes and vessels to minimize product losses and to ensure the purity of your products.
Suspended solids measurement, product interface detection, milk detection, produkt loss detection. Glass-free and hygienic design.

OUSAF11 Measured variable

  • VIS/NIR absorption

OUSAF11 measuring range

• 0 to 3 AU
• 0 to 6 OD (depending on optical path length)

OUSAF11 wavelength

NIR, broadband (VIS and NIR)

OUSAF11 application

Endress OUSAF11 sensor detects phase separations and suspended solids in :
• Food & Beverages:
- Milk detection in CIP solutions
- Phase separation in dairies and breweries
- Product loss detection in effluent
• Primaries, mining and metals:
- Suspended solids measurement

OUSAF11 advantages

• Highest safety for your products thanks to glass-free, hygienic design
• Cost savings and reduced product loss thanks to fast interphase detection
• Low-maintenance sensor with long service life and stable operation
• Flexible installation: Sensor features insertion (with Triclamp and Varivent connection) and immersion (with holder and assembly system Flexdip CYA112 and CYH112)
• Robust sensor resists aggressive chemicals and fouling
• Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)
• FDA and 3-A approval
• Ingres protection IP 67, IP 68 if mounted with CYH112

OUSAF11 process temperature

0 to 90 °C (32 to 194 °F) continuous
Max. 130 °C (266 °F) for 2 hours

OUSAF11 process pressure

Max. 10 bar abs at 20 °C (Max. 150 psi at 68 °F)

OUSAF11-AA210A2A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA210A2A15A

Endress + Hauser OUSAF11-AA210A2A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-11E7/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA210A2A15A

OUSAF11-AA105B3A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA105B3A15A

Endress + Hauser OUSAF11-AA105B3A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2H00/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA105B3A15A

OUSAF11-AA110A3A10A

© E+H NIR-VIS absorption sensor OUSAF11-AA110A3A10A

Endress + Hauser OUSAF11-AA110A3A10A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-1KC0/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA110A3A10A

OUSAF11-AA105B2A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA105B2A15A

Endress + Hauser OUSAF11-AA105B2A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2FV0/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA105B2A15A

OUSAF11-AA205B1A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA205B1A15A

Endress + Hauser OUSAF11-AA205B1A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-15A6/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA205B1A15A

OUSAF11-AA110A1A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA110A1A15A

Endress + Hauser OUSAF11-AA110A1A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2FR8/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA110A1A15A

OUSAF11-AA210B1A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA210B1A15A

Endress + Hauser OUSAF11-AA210B1A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-1K69/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA210B1A15A

OUSAF11-AA110B1A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA110B1A15A

Endress + Hauser OUSAF11-AA110B1A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-11F2/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA110B1A15A

OUSAF11-AA205B3A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA205B3A15A

Endress + Hauser OUSAF11-AA205B3A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2H15/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA205B3A15A

OUSAF11-AA110B3A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA110B3A15A

Endress + Hauser OUSAF11-AA110B3A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-1PF0/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA110B3A15A

OUSAF11-AA210B3A10A

© E+H NIR-VIS absorption sensor OUSAF11-AA210B3A10A

Endress + Hauser OUSAF11-AA210B3A10A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2DR4/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA210B3A10A

OUSAF11-AA210B3A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA210B3A15A

Endress + Hauser OUSAF11-AA210B3A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-1PE5/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA210B3A15A

OUSAF11-AA105A1A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA105A1A15A

Endress + Hauser OUSAF11-AA105A1A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-12J4/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA105A1A15A

OUSAF11-AA205A1A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA205A1A15A

Endress + Hauser OUSAF11-AA205A1A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2FQ2/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA205A1A15A

OUSAF11-AA105C1A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA105C1A15A

Endress + Hauser OUSAF11-AA105C1A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-1JC6/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA105C1A15A

OUSAF11-AA210A3A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA210A3A15A

Endress + Hauser OUSAF11-AA210A3A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-1EC1/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA210A3A15A

OUSAF11-AA105B1A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA105B1A15A

Endress + Hauser OUSAF11-AA105B1A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-1P16/0 Endress + Hauser OUSAF11-AA105B1A15A AA Approval: Non-hazardous area 1 Wavelength: … [Read more...] about OUSAF11-AA105B1A15A

OUSAF11-AA105A2A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA105A2A15A

Endress + Hauser OUSAF11-AA105A2A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-1061/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA105A2A15A

OUSAF11-AA205C1A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA205C1A15A

Endress + Hauser OUSAF11-AA205C1A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2H20/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA205C1A15A

OUSAF11-AA110C1A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA110C1A15A

Endress + Hauser OUSAF11-AA110C1A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-1MD2/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA110C1A15A

OUSAF11-AA210B2A10A

© E+H NIR-VIS absorption sensor OUSAF11-AA210B2A10A

Endress + Hauser OUSAF11-AA210B2A10A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2FM0/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA210B2A10A

OUSAF11-AA205B3A10A

© E+H NIR-VIS absorption sensor OUSAF11-AA205B3A10A

Endress + Hauser OUSAF11-AA205B3A10A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2FN6/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA205B3A10A

OUSAF11-AA210B2A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA210B2A15A

Endress + Hauser OUSAF11-AA210B2A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2FX0/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA210B2A15A

OUSAF11-AA210A1A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA210A1A15A

Endress + Hauser OUSAF11-AA210A1A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2FT9/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA210A1A15A

OUSAF11-AA205C1A10A

© E+H NIR-VIS absorption sensor OUSAF11-AA205C1A10A

Endress + Hauser OUSAF11-AA205C1A10A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-1DU6/0 Endress + Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA205C1A10A

OUSAF11-AA205B2A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA205B2A15A

Endress + Hauser OUSAF11-AA205B2A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2FW5/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA205B2A15A

OUSAF11-AA205A3A10A

© E+H NIR-VIS absorption sensor OUSAF11-AA205A3A10A

Endress + Hauser OUSAF11-AA205A3A10A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-13C0/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA205A3A10A

OUSAF11-AA210C1A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA210C1A15A

Endress + Hauser OUSAF11-AA210C1A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2H36/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 2 Wavelength: Broadband, … [Read more...] about OUSAF11-AA210C1A15A

OUSAF11-AA110B2A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA110B2A15A

Endress + Hauser OUSAF11-AA110B2A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-1A30/0 Endress Hauser OUSAF11 AA Approval: Non-hazardous area 1 Wavelength: NIR, 725-1100 … [Read more...] about OUSAF11-AA110B2A15A

OUSAF11-AA110A3A15A

© E+H NIR-VIS absorption sensor OUSAF11-AA110A3A15A

Endress + Hauser OUSAF11-AA110A3A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2C89/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA110A3A15A

  • Go to page 1
  • Go to page 2
  • Go to Next Page »

Primary Sidebar

Contact us:





    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • CPS41E-IA7BSC2
    • FDU95-E2G3A
    • FTL70-DAE6AE7E7NN
    • FTL50-DBB2QA4F7D
    • FTL50-SBD2AADE1C
    • CPS96E-BA7BTH5
    • CPS41E-MA7BSB4
    • FDU95-H1G1A
    • FTL70-NAE6AE6E8AL
    • FTL50-SBA2IA7E5A
    • FTL50-WAL2AA4G5D
    • CPS96E-UR7BTH6+Z1
    • Fristam 0810610010 SLIDE RING D=22 FOR HR7/22 TUNGSTEN CARBIDE
    • CPS41E-IA7BSB5
    • FTL70-AAE6AEAF1CL
    • FTL50-IBB2QA4F7D
    • CPS96E-KA7BTH5+Z1
    • Fristam 0817310036 Spare mechanical seal 729a 2L 5P
    • CPS41E-GR7BSB5
    • FDU95-D1G6A

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2023 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.