Endress + Hauser OUA260 Flow assembly for optical inline measurements used with sensors OUSAF12 OUSAF22 OUSAF44 OUSTF10

ENDRESS + HAUSER Flow assembly for optical inline measurements OUA260

E+H OUA260 is the best-in-class flow assembly for absorption, color and turbidity measurements in combination with E+H OUSAF12, OUSAF22, OUSAF44, and OUSTF10. Its ultra-hygienic design and certified biocompatibility meet the highest demands to protect your products reliably from contamination.

OUA260 Measured variable

  • UV absorbance

OUA260 measuring range

depending on installed sensors

OUA260 materials

Body: SS316L, Kynar, further on request
Windows: Pyrex, Quartz or Sapphire
O-rings: Viton, Silicone, EPDM, Kalrez

OUA260 application

Endress OUA260 flow cell is used in combination with:
• OUSAF12 Suspended solids and color sensor
• OUSAF22 Color sensor
• OUSAF44 UV absorption sensor
• OUSTF10 Turbidity and suspended solids sensor
Typical applications are:
• Chromatography control
• Filtration monitoring
• Color measurement
• Centrifuge control
• Protein concentration
• Turbidity measurement
• Phase detection
OUA260 is suitable for hazardous area use.

OUA260 advantages

• Fast measuring values thanks to low cell volume
• Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)
• Certified biocompatibility according to USP class VI
• Ultra-hygienic thanks to electropolished surface Ra=0.4 µm (16 µinch)
• Extremely corrosion-resistant
• Wide range of materials and process connections for perfect fit into every application
• Wide range of optical window materials and path lengths for optimum adaption to every process

OUA260 process temperature

0-130 °C (32-194 °F)

OUA260 process pressure

up to 100 bar (1450 psi) depending on material, mean diameter and process connection

OUA260-AE1B03B2B3A

© E+H Flow cell OUA260-AE1B03B2B3A

Endress + Hauser OUA260-AE1B03B2B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 A Sensor type: for OUSAF44/OUSAF46 E1 Process Connection: Swagelock BVCO B Mean diameter: 0.375” 03 Optical Pathlength (OPL): 1 mm with POPL B Window … [Read more...] about OUA260-AE1B03B2B3A

OUA260-BA1I11C4B3B

© E+H Flow cell OUA260-BA1I11C4B3B

Endress + Hauser OUA260-BA1I11C4B3B Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A1 Process Connection: Triclover 316L I Mean diameter: 2” 11 Optical Pathlength (OPL): 40 mm Standard (for TF … [Read more...] about OUA260-BA1I11C4B3B

OUA260-BA1C05C4B3B

© E+H Flow cell OUA260-BA1C05C4B3B

Endress + Hauser OUA260-BA1C05C4B3B Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A1 Process Connection: Triclover 316L C Mean diameter: 0.5” 05 Optical Pathlength (OPL): 2 mm with POPL C Window … [Read more...] about OUA260-BA1C05C4B3B

OUA260-AA1C05C4B3B

© E+H Flow cell OUA260-AA1C05C4B3B

Endress + Hauser OUA260-AA1C05C4B3B Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 A Sensor type: for OUSAF44/OUSAF46 A1 Process Connection: Triclover 316L C Mean diameter: 0.5” 05 Optical Pathlength (OPL): 2 mm with POPL C Window … [Read more...] about OUA260-AA1C05C4B3B

OUA260-BA1A01B1A1A

© E+H Flow cell OUA260-BA1A01B1A1A

Endress + Hauser OUA260-BA1A01B1A1A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A1 Process Connection: Triclover 316L A Mean diameter: 0.25” 01 Optical Pathlength (OPL): 0.5 mm with POPL B Window … [Read more...] about OUA260-BA1A01B1A1A

OUA260-AE1A01B1A1A

© E+H Flow cell OUA260-AE1A01B1A1A

Endress + Hauser OUA260-AE1A01B1A1A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 A Sensor type: for OUSAF44/OUSAF46 E1 Process Connection: Swagelock BVCO A Mean diameter: 0.25” 01 Optical Pathlength (OPL): 0.5 mm with POPL B Window … [Read more...] about OUA260-AE1A01B1A1A

OUA260-BA2C04C4B3B

© E+H Flow cell OUA260-BA2C04C4B3B

Endress + Hauser OUA260-BA2C04C4B3B Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A2 Process Connection: Triclover Kynar, non ex C Mean diameter: 0.5” 04 Optical Pathlength (OPL): 2 mm Standard … [Read more...] about OUA260-BA2C04C4B3B

OUA260-AA1C04C4B3B

© E+H Flow cell OUA260-AA1C04C4B3B

Endress + Hauser OUA260-AA1C04C4B3B Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 A Sensor type: for OUSAF44/OUSAF46 A1 Process Connection: Triclover 316L C Mean diameter: 0.5” 04 Optical Pathlength (OPL): 2 mm Standard C Window … [Read more...] about OUA260-AA1C04C4B3B

OUA260-AE1A09B1A1A

© E+H Flow cell OUA260-AE1A09B1A1A

Endress + Hauser OUA260-AE1A09B1A1A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 A Sensor type: for OUSAF44/OUSAF46 E1 Process Connection: Swagelock BVCO A Mean diameter: 0.25” 09 Optical Pathlength (OPL): 20 mm Standard B Window … [Read more...] about OUA260-AE1A09B1A1A

OUA260-BA1I12C4B3B

© E+H Flow cell OUA260-BA1I12C4B3B

Endress + Hauser OUA260-BA1I12C4B3B Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A1 Process Connection: Triclover 316L I Mean diameter: 2” 12 Optical Pathlength (OPL): 50 mm Standard C Window … [Read more...] about OUA260-BA1I12C4B3B

OUA260-BA1I10C4B3B

© E+H Flow cell OUA260-BA1I10C4B3B

Endress + Hauser OUA260-BA1I10C4B3B Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A1 Process Connection: Triclover 316L I Mean diameter: 2” 10 Optical Pathlength (OPL): 30 mm Standard C Window … [Read more...] about OUA260-BA1I10C4B3B

OUA260-AA2C04C4B3A

© E+H Flow cell OUA260-AA2C04C4B3A

Endress + Hauser OUA260-AA2C04C4B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 A Sensor type: for OUSAF44/OUSAF46 A2 Process Connection: Triclover Kynar, non ex C Mean diameter: 0.5” 04 Optical Pathlength (OPL): 2 mm Standard … [Read more...] about OUA260-AA2C04C4B3A

OUA260-BE2A01B1A1A

© E+H Flow cell OUA260-BE2A01B1A1A

Endress + Hauser OUA260-BE2A01B1A1A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 E2 Process Connection: Swagelock Tube A Mean diameter: 0.25” 01 Optical Pathlength (OPL): 0.5 mm with POPL B Window … [Read more...] about OUA260-BE2A01B1A1A

OUA260-BA1B03B2B3B

© E+H Flow cell OUA260-BA1B03B2B3B

Endress + Hauser OUA260-BA1B03B2B3B Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A1 Process Connection: Triclover 316L B Mean diameter: 0.375” 03 Optical Pathlength (OPL): 1 mm with POPL B Window … [Read more...] about OUA260-BA1B03B2B3B

OUA260-AA1B03B2B3B

© E+H Flow cell OUA260-AA1B03B2B3B

Endress + Hauser OUA260-AA1B03B2B3B Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 A Sensor type: for OUSAF44/OUSAF46 A1 Process Connection: Triclover 316L B Mean diameter: 0.375” 03 Optical Pathlength (OPL): 1 mm with POPL B Window … [Read more...] about OUA260-AA1B03B2B3B

OUA260-AE2A01B1A1A

© E+H Flow cell OUA260-AE2A01B1A1A

Endress + Hauser OUA260-AE2A01B1A1A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 A Sensor type: for OUSAF44/OUSAF46 E2 Process Connection: Swagelock Tube A Mean diameter: 0.25” 01 Optical Pathlength (OPL): 0.5 mm with POPL B Window … [Read more...] about OUA260-AE2A01B1A1A

OUA260-BA1I11C4B3A

© E+H Flow cell OUA260-BA1I11C4B3A

Endress + Hauser OUA260-BA1I11C4B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A1 Process Connection: Triclover 316L I Mean diameter: 2” 11 Optical Pathlength (OPL): 40 mm Standard (for TF … [Read more...] about OUA260-BA1I11C4B3A

OUA260-BE1A01B1A1A

© E+H Flow cell OUA260-BE1A01B1A1A

Endress + Hauser OUA260-BE1A01B1A1A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 E1 Process Connection: Swagelock BVCO A Mean diameter: 0.25” 01 Optical Pathlength (OPL): 0.5 mm with POPL B Window … [Read more...] about OUA260-BE1A01B1A1A

OUA260-BE2B07B2B3A

© E+H Flow cell OUA260-BE2B07B2B3A

Endress + Hauser OUA260-BE2B07B2B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 E2 Process Connection: Swagelock Tube B Mean diameter: 0.375” 07 Optical Pathlength (OPL): 5 mm with POPL B Window … [Read more...] about OUA260-BE2B07B2B3A

OUA260-AA2B03B2B3B

© E+H Flow cell OUA260-AA2B03B2B3B

Endress + Hauser OUA260-AA2B03B2B3B Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 A Sensor type: for OUSAF44/OUSAF46 A2 Process Connection: Triclover Kynar, non ex B Mean diameter: 0.375” 03 Optical Pathlength (OPL): 1 mm with POPL … [Read more...] about OUA260-AA2B03B2B3B

OUA260-BA2C04C4B3A

© E+H Flow cell OUA260-BA2C04C4B3A

Endress + Hauser OUA260-BA2C04C4B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A2 Process Connection: Triclover Kynar, non ex C Mean diameter: 0.5” 04 Optical Pathlength (OPL): 2 mm Standard … [Read more...] about OUA260-BA2C04C4B3A

OUA260-BA2A01B1A1A

© E+H Flow cell OUA260-BA2A01B1A1A

Endress + Hauser OUA260-BA2A01B1A1A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A2 Process Connection: Triclover Kynar, non ex A Mean diameter: 0.25” 01 Optical Pathlength (OPL): 0.5 mm with POPL … [Read more...] about OUA260-BA2A01B1A1A

OUA260-BA1C04C4B3B

© E+H Flow cell OUA260-BA1C04C4B3B

Endress + Hauser OUA260-BA1C04C4B3B Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A1 Process Connection: Triclover 316L C Mean diameter: 0.5” 04 Optical Pathlength (OPL): 2 mm Standard C Window … [Read more...] about OUA260-BA1C04C4B3B

OUA260-AA1A01B1A1A

Endress + Hauser OUA260-AA1A01B1A1A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA260 A Sensor type: for OUSAF44/OUSAF46 A1 Process Connection: Triclover 316L A Mean diameter: 0.25” 01 Optical Pathlength (OPL): 0.5 mm with POPL B Window … [Read more...] about OUA260-AA1A01B1A1A

OUA260-AE2B03B2B3A

© E+H Flow cell OUA260-AE2B03B2B3A

Endress + Hauser OUA260-AE2B03B2B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 A Sensor type: for OUSAF44/OUSAF46 E2 Process Connection: Swagelock Tube B Mean diameter: 0.375” 03 Optical Pathlength (OPL): 1 mm with POPL B Window … [Read more...] about OUA260-AE2B03B2B3A

OUA260-BA1C05C4B3A

© E+H Flow cell OUA260-BA1C05C4B3A

Endress + Hauser OUA260-BA1C05C4B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A1 Process Connection: Triclover 316L C Mean diameter: 0.5” 05 Optical Pathlength (OPL): 2 mm with POPL C Window … [Read more...] about OUA260-BA1C05C4B3A

OUA260-BA1C04C4B3A

© E+H Flow cell OUA260-BA1C04C4B3A

Endress + Hauser OUA260-BA1C04C4B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A1 Process Connection: Triclover 316L C Mean diameter: 0.5” 04 Optical Pathlength (OPL): 2 mm Standard C Window … [Read more...] about OUA260-BA1C04C4B3A

OUA260-BA2C05C4B3B

© E+H Flow cell OUA260-BA2C05C4B3B

Endress + Hauser OUA260-BA2C05C4B3B Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A2 Process Connection: Triclover Kynar, non ex C Mean diameter: 0.5” 05 Optical Pathlength (OPL): 2 mm with POPL … [Read more...] about OUA260-BA2C05C4B3B

OUA260-BF1B03B2B3A

© E+H Flow cell OUA260-BF1B03B2B3A

Endress + Hauser OUA260-BF1B03B2B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 F1 Process Connection: Tube Stub B Mean diameter: 0.375” 03 Optical Pathlength (OPL): 1 mm with POPL B Window … [Read more...] about OUA260-BF1B03B2B3A

OUA260-BE1B08B2B3A

© E+H Flow cell OUA260-BE1B08B2B3A

Endress + Hauser OUA260-BE1B08B2B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 E1 Process Connection: Swagelock BVCO B Mean diameter: 0.375” 08 Optical Pathlength (OPL): 10 mm Standard B Window … [Read more...] about OUA260-BE1B08B2B3A

  • Go to page 1
  • Go to page 2
  • Go to Next Page »

Primary Sidebar

Contact us:





    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • CM444R-CDM4BA1FK6
    • CPS16E-KA7ATA2
    • CPS16E-NA7ATA4
    • CPS16E-GR7BTA4
    • CM444R-CAM4BA5FA1
    • CPS16E-JA7ATA4
    • CPS92E-BA7PHH5+Z1
    • CPS16E-CB7ATA4
    • CPS92E-UA7PHH4+Z1
    • CPS41E-NA7ASC5
    • 10D25-3TGA1AA0A0BA
    • CPS92E-UA7PHH2+Z1
    • CPS41E-JA7BSB4
    • 10D25-6VGAEAA0A0BA
    • CPS92E-MA7PHH5
    • CPS92E-IA7PHH2
    • CPS41E-IA7BSB4
    • 10D25-7LGA1AA0A0BA
    • CPS92E-MA7PHH4
    • CPS41E-BA7ASB4

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2023 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.