• Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Bromberg, Staudt & Co. GmbH

  • Home
  • About us
  • Our services
  • Industries
  • Brands
    • Bürkert
    • Endress+Hauser
    • EAGLE Burgmann Mechanical Shaft Seals
  • Contacts
  • English
    • Español
    • Tagalog
    • 한국어
    • 中文 (中国)
    • Deutsch
Home / Endress+Hauser / E+H Analytics / Sensors/Electrodes / CPS71

Endress + Hauser CPS71 analog pH sensor for food and life sciences industries

ENDRESS + HAUSER analog pH sensor CPS71

CPS71 sensor is the analog specialist for pH measurement in sterile and hygienic applications. Resistant against reference poisoning - CIP/SIP and autoclavable - high accuracy - biocompatibility of the gel inside - version upside-down installation available - pressurized reference (6 bar) available

CPS71 measured value

  • pH
  • Temperature

CPS71 application

• Hygienic and sterile applications:
- Fermenters
- Biotechnology
- Life sciences
- Food industry
• Process technology and monitoring of processes with:
- Quickly changing pH values
- High proportion of electrode poisons such as H2S
With ATEX, FM, and CSA approval for application in hazardous areas

CPS71 advantages

• Suitable for CIP/SIP and autoclaving maintaining high accuracy
• Sensor resists strong acids and bases and high organic loads
• Certified biocompatibility, no cytotoxicity
• Free from animal-based materials and from acrylamide

CPS71 measuring range

Electrode version TB, TC:
pH: 0 to 14 pH
Temperature: • 0 to 140 °C (32 to 284 °F)
• 0 to 135 °C (32 to 275 °F) for sensors with Ex approval and analog
sensors
Electrode version TP (pressurized reference):
pH: 0 to 12 pH
Temperature: • 0 to 140 °C (32 to 284 °F)
(140 °C (284 °F) only for sterilization)
• 0 to 135 °C (32 to 275 °F) for sensors with Ex approval and analog
sensors
(135 °C (275 °F) only for sterilization)
• Max. 100 °C (212 °F) in continuous operation due to increasing
pressure loss at T > 100 °C (212 °F)
Electrode version TU:
pH: 0 to 14 pH
Temperature: • 0 to 140 °C (32 to 284 °F)
(140 °C (284 °F) only for sterilization)
• 0 to 135 °C (32 to 275 °F) for sensors with Ex approval and analog
sensors
(135 °C (275 °F) only for sterilization)
• Max. 100 °C (212 °F) in continuous operation due to liquefaction of
gel-based inner electrolyte at T > 100 °C (212 °F)

CPS71 process temperature

-15°C ... 140°C (5°F - 284°F)

CPS71 process pressure

max. 13 bar (188 psi)

CPS71 storage temperature

0 to 50 °C (32 to 120 °F)

Also available as
CPS71D DIGITAL PH SENSOR (phase-out type)
or latest version
CPS71E DIGITAL PH SENSOR MEMOSENS 2.0


CPS71-2TC4ESA

© E+H pH-comb. electrode CPS71-2TC4ESA

Endress + Hauser CPS71-2TC4ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TC4ESA

CPS71-1TB4ESA

© E+H pH-comb. electrode CPS71-1TB4ESA

Endress + Hauser CPS71-1TB4ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 1 Electrode Type: Zero point … [Read more...] about CPS71-1TB4ESA

CPS71-2TP5ESC

© E+H pH-comb. electrode CPS71-2TP5ESC

Endress + Hauser CPS71-2TP5ESC pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TP5ESC

CPS71-3TB6ESA

© E+H pH-comb. electrode CPS71-3TB6ESA

Endress + Hauser CPS71-3TB6ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TB6ESA

CPS71-1TC2ESA

© E+H pH-comb. electrode CPS71-1TC2ESA

Endress + Hauser CPS71-1TC2ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 1 Electrode Type: Zero point … [Read more...] about CPS71-1TC2ESA

CPS71-3TC5ESA

© E+H pH-comb. electrode CPS71-3TC5ESA

Endress + Hauser CPS71-3TC5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TC5ESA

CPS71-3TP4ESA

© E+H pH-comb. electrode CPS71-3TP4ESA

Endress + Hauser CPS71-3TP4ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TP4ESA

CPS71-2TC5ESA

© E+H pH-comb. electrode CPS71-2TC5ESA

Endress + Hauser CPS71-2TC5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TC5ESA

CPS71-2TP4ESC

© E+H pH-comb. electrode CPS71-2TP4ESC

Endress + Hauser CPS71-2TP4ESC pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TP4ESC

CPS71-2TP5ESA

© E+H pH-comb. electrode CPS71-2TP5ESA

Endress + Hauser CPS71-2TP5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TP5ESA

CPS71-2TU2ESA

© E+H pH-comb. electrode CPS71-2TU2ESA

Endress + Hauser CPS71-2TU2ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TU2ESA

CPS71-1TB6ESA

© E+H pH-comb. electrode CPS71-1TB6ESA

Endress + Hauser CPS71-1TB6ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 1 Electrode Type: Zero point … [Read more...] about CPS71-1TB6ESA

CPS71-2TP2ESA

© E+H pH-comb. electrode CPS71-2TP2ESA

Endress + Hauser CPS71-2TP2ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TP2ESA

CPS71-1TB5ESA

© E+H pH-comb. electrode CPS71-1TB5ESA

Endress + Hauser CPS71-1TB5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 1 Electrode Type: Zero point … [Read more...] about CPS71-1TB5ESA

CPS71-2TB5ESA

© E+H pH-comb. electrode CPS71-2TB5ESA

Endress + Hauser CPS71-2TB5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TB5ESA

CPS71-3TC2ESA

© E+H pH-comb. electrode CPS71-3TC2ESA

Endress + Hauser CPS71-3TC2ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TC2ESA

CPS71-1TC4ESA

© E+H pH-comb. electrode CPS71-1TC4ESA

Endress + Hauser CPS71-1TC4ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 1 Electrode Type: Zero point … [Read more...] about CPS71-1TC4ESA

CPS71-3TB5ESA

© E+H pH-comb. electrode CPS71-3TB5ESA

Endress + Hauser CPS71-3TB5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TB5ESA

CPS71-2TU5ESC

© E+H pH-comb. electrode CPS71-2TU5ESC

Endress + Hauser CPS71-2TU5ESC pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TU5ESC

CPS71-2TC2ESA

© E+H pH-comb. electrode CPS71-2TC2ESA

Endress + Hauser CPS71-2TC2ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TC2ESA

CPS71-2TB6ESA

© E+H pH-comb. electrode CPS71-2TB6ESA

Endress + Hauser CPS71-2TB6ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TB6ESA

CPS71-3TU5ESA

© E+H pH-comb. electrode CPS71-3TU5ESA

Endress + Hauser CPS71-3TU5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TU5ESA

CPS71-1TB2ESC

© E+H pH-comb. electrode CPS71-1TB2ESC

Endress + Hauser CPS71-1TB2ESC pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 1 Electrode Type: Zero point … [Read more...] about CPS71-1TB2ESC

CPS71-3TP2ESA

© E+H pH-comb. electrode CPS71-3TP2ESA

Endress + Hauser CPS71-3TP2ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TP2ESA

CPS71-2TU4ESC

Endress + Hauser CPS71-2TU4ESC pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 2 Electrode Type: Zero point … [Read more...] about CPS71-2TU4ESC

CPS71-1TC5ESA

© E+H pH-comb. electrode CPS71-1TC5ESA

Endress + Hauser CPS71-1TC5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 1 Electrode Type: Zero point … [Read more...] about CPS71-1TC5ESA

CPS71-3TP6ESA

© E+H pH-comb. electrode CPS71-3TP6ESA

Endress + Hauser CPS71-3TP6ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TP6ESA

CPS71-1TC2ESC

© E+H pH-comb. electrode CPS71-1TC2ESC

Endress + Hauser CPS71-1TC2ESC pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 1 Electrode Type: Zero point … [Read more...] about CPS71-1TC2ESC

CPS71-3TP5ESA

© E+H pH-comb. electrode CPS71-3TP5ESA

Endress + Hauser CPS71-3TP5ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TP5ESA

CPS71-1TC6ESA

© E+H pH-comb. electrode CPS71-1TC6ESA

Endress + Hauser CPS71-1TC6ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 1 Electrode Type: Zero point … [Read more...] about CPS71-1TC6ESA

  • Page 1
  • Page 2
  • Go to Next Page »

Primary Sidebar

Contact us:





    What is 1 x 7

    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • TM131-U4AAAFA2AA3AAAB0AA1AA1
    • TM131-URAAAFA2AA3AAAB0AA1AA1
    • TM131-U5AAAFA2AA3AAAB0AA1AA1
    • TM131-8FAAAFA2AA3AAAB0AA1AA1
    • TM131-URAAAFA2AA2AAAB0AA1AA1
    • TM131-U4AAAFA2AA2AAAB0AA1AA1
    • TM131-8FAAAFA1AA3AAAB0AA1AA1
    • TM131-AAAAAFA1AA4AAAB0AA1AA1
    • TM131-G4AAAFA1AA8AAAB0AA1AA1
    • TM131-84AAAFA2AA2AAAB0AA1AA1
    • TM131-CGAAAFA2AA3AAAB0AA1AA1
    • TM131-GFAAAFA2AA3AAAB0AA1AA1
    • TM121-GRHBB1A6BC1A3A1
    • TM131-GJAAAFA1AA5AAAB0AA1AA1
    • TM131-MAAAAFA1AA8AAAB0AA1AA1
    • TM121-AAACB1A4BA1A3A1
    • TM111-MAAABA1BBB0AA1AA1
    • TM111-U5ABAA1BBB0AA1AA1
    • TM121-URA4BA1A3A1
    • TM131-NFAAAFA1AA4AAAB0AA1AA1

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2025 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.