Endress + Hauser Digital chlorine dioxide robust low maintenance sensor Memosens CCS50D

ENDRESS + HAUSER Digital chlorine dioxide sensor CCS50D

Endress+Hauser Memosens CCS50D is a robust, low maintenance sensor for chlorine dioxide measurement. It provides stable and fast measured values in drinking water, process water and utilities.
Amperometric measurement of dissolved chlorine dioxide.

CCS50D application

Memosens CCS50D is a chlorine dioxide sensor for skid builders and end customers. It measures reliably in:
• Drinking water to ensure sufficient disinfection
• Cooling systems or towers to avoid pathogen growth
• Wash water for packed vegetables and salads to ensure food quality
• Beverage plants to secure the absence of chlorine dioxide

CCS50D advantages

• The right sensor version for every application: From trace measurement up to chlorine dioxide concentrations of 200 mg/l.
• Fast response time provides accurate process view and enables prompt reaction to process changes as well as efficient process control.
• Increased process safety: precise and long-term stable measurement ensures consistent process monitoring and allows for lowest disinfectant concentration.
• Flexible installation: sensor can be installed in the CCA151 and CCA250 flow assemblies or in immersion assemblies. Measurement virtually flow independent at flow velocities above 5 l/h (CCA151), 30 l/h (CCA250) or above 15 cm/s (immersion).
• More process up-time thanks to fast sensor exchange: precalibrate the sensor in your lab and then swap it into your process with plug & play.
• Connection to the Liquiline multiparameter transmitter allows easy combination with other relevant parameters of liquid analysis.

CCS50D measured value

  • Chlorine dioxide

CCS50D measuring range

Trace: 0 to 5 mg/l ClO2
Standard: 0 to 20 mg/l ClO2
High: 0 to 200 mg/l ClO2

CCS50D process temperature

0 to 55 °C , non-freezing - (32 to 130 °F)

CCS50D process pressure

Max. 2 bar abs (Max. 29 psi abs)

CCS50D-CD11BF+ND

© E+H Chlorine dioxide sensor CCS50D-CD11BF+ND

Endress + Hauser CCS50D-CD11BF+ND Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-CD11BF+ND

CCS50D-GR11BF+ND

© E+H Chlorine dioxide sensor GR11BF+ND

Endress + Hauser CCS50D-GR11BF+ND Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-GR11BF+ND

CCS50D-AA11BF

© E+H Chlorine dioxide sensor CCS50D-AA11BF

Endress + Hauser CCS50D-AA11BF Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-AA11BF

CCS50D-GR11AD+NBZ1

© E+H Chlorine dioxide sensor CCS50D-GR11AD+NBZ1

Endress + Hauser CCS50D-GR11AD+NBZ1 Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-GR11AD+NBZ1

CCS50D-AA11CJ+NB

© E+H Chlorine dioxide sensor CCS50D-AA11CJ+NB

Endress + Hauser CCS50D-AA11CJ+NB Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-AA11CJ+NB

CCS50D-CD11BF+NC

© E+H Chlorine dioxide sensor CCS50D-CD11BF+NC

Endress + Hauser CCS50D-CD11BF+NC Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-CD11BF+NC

CCS50D-CD11AD+ND

© E+H Chlorine dioxide sensor CCS50D-CD11AD+ND

Endress + Hauser CCS50D-CD11AD+ND Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-CD11AD+ND

CCS50D-GR11AD

© E+H Chlorine dioxide sensor CCS50D-GR11AD

Endress + Hauser CCS50D-GR11AD Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-GR11AD

CCS50D-CD11CJ

© E+H Chlorine dioxide sensor CCS50D-CD11CJ

Endress + Hauser CCS50D-CD11CJ Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-CD11CJ

CCS50D-CD11BF

© E+H Chlorine dioxide sensor CCS50D-CD11BF

Endress + Hauser CCS50D-CD11BF Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-CD11BF

CCS50D-CD11CJ+NBZ1

© E+H Chlorine dioxide sensor CCS50D-CD11CJ+NBZ1

Endress + Hauser CCS50D-CD11CJ+NBZ1 Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-CD11CJ+NBZ1

CCS50D-GR11AD+NB

Endress + Hauser CCS50D-GR11AD+NB Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-GR11AD+NB

CCS50D-AA11CJ+NBZ1

© E+H Chlorine dioxide sensor CCS50D-AA11CJ+NBZ1

Endress + Hauser CCS50D-AA11CJ+NBZ1 Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-AA11CJ+NBZ1

CCS50D-AA11BF+ND

© E+H Chlorine dioxide sensor CCS50D-AA11BF+ND

Endress + Hauser CCS50D-AA11BF+ND Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-AA11BF+ND

CCS50D-GR11CJ+ND

© E+H Chlorine dioxide sensor CCS50D-GR11CJ+ND

Endress + Hauser CCS50D-GR11CJ+ND Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-GR11CJ+ND

CCS50D-GR11CJ+NC

© E+H Chlorine dioxide sensor CCS50D-GR11CJ+NC

Endress + Hauser CCS50D-GR11CJ+NC Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-GR11CJ+NC

CCS50D-GR11BF+NB

© E+H Chlorine dioxide sensor CCS50D-GR11BF+NB

Endress + Hauser CCS50D-GR11BF+NB Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-GR11BF+NB

CCS50D-CD11CJ+NB

Endress + Hauser CCS50D-CD11CJ+NB Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety low-maintenance sensor, broad measuring range (0 - 200 mg/l ClO2), ::long-time stable measurement, … [Read more...] about CCS50D-CD11CJ+NB

CCS50D-CD11AD+NBZ1

© E+H Chlorine dioxide sensor CCS50D-CD11AD+NBZ1

Endress + Hauser CCS50D-CD11AD+NBZ1 Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-CD11AD+NBZ1

CCS50D-AA11AD+NBZ1

© E+H Chlorine dioxide sensor CCS50D-AA11AD+NBZ1

Endress + Hauser CCS50D-AA11AD+NBZ1 Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-AA11AD+NBZ1

CCS50D-AA11CJ+NC

© E+H Chlorine dioxide sensor CCS50D-AA11CJ+NC

Endress + Hauser CCS50D-AA11CJ+NC Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-AA11CJ+NC

CCS50D-CD11BF+NBZ1

Endress + Hauser CCS50D-CD11BF+NBZ1 Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-CD11BF+NBZ1

CCS50D-CD11CJ+ND

© E+H Chlorine dioxide sensor CCS50D-CD11CJ+ND

Endress + Hauser CCS50D-CD11CJ+ND Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-CD11CJ+ND

CCS50D-GR11BF+NBZ1

© E+H Chlorine dioxide sensor CCS50D-GR11BF+NBZ1

Endress + Hauser CCS50D-GR11BF+NBZ1 Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-GR11BF+NBZ1

CCS50D-GR11AD+ND

© E+H Chlorine dioxide sensor CCS50D-GR11AD+ND

Endress + Hauser CCS50D-GR11AD+ND Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-GR11AD+ND

CCS50D-AA11CJ+ND

© E+H Chlorine dioxide sensor CCS50D-AA11CJ+ND

Endress + Hauser CCS50D-AA11CJ+ND Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-AA11CJ+ND

CCS50D-CD11BF+NB

© E+H Chlorine dioxide sensor CCS50D-CD11BF+NB

Endress + Hauser CCS50D-CD11BF+NB Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-CD11BF+NB

CCS50D-AA11BF+NBZ1

© E+H Chlorine dioxide sensor CCS50D-AA11BF+NBZ1

Endress + Hauser CCS50D-AA11BF+NBZ1 Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-AA11BF+NBZ1

CCS50D-AA11AD+NC

© E+H Chlorine dioxide sensor CCS50D-AA11AD+NC

Endress + Hauser CCS50D-AA11AD+NC Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-AA11AD+NC

CCS50D-GR11BF+NC

© E+H Chlorine dioxide sensor CCS50D-GR11BF+NC

Endress + Hauser CCS50D-GR11BF+NC Chlorine dioxide sensor (25 mm diameter), amperometric, membrane-covered Memosens sensor, Reliable disinfection for potable and cooling water, safety in food industry, utilities, low-maintenance sensor, broad measuring range (0 - 200 mg/l … [Read more...] about CCS50D-GR11BF+NC

  • Go to page 1
  • Go to page 2
  • Go to Next Page »

Primary Sidebar

Contact us:





    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • CM444R-CDM4BA1FK6
    • CPS16E-KA7ATA2
    • CPS16E-NA7ATA4
    • CPS16E-GR7BTA4
    • CM444R-CAM4BA5FA1
    • CPS16E-JA7ATA4
    • CPS92E-BA7PHH5+Z1
    • CPS16E-CB7ATA4
    • CPS92E-UA7PHH4+Z1
    • CPS41E-NA7ASC5
    • 10D25-3TGA1AA0A0BA
    • CPS92E-UA7PHH2+Z1
    • CPS41E-JA7BSB4
    • 10D25-6VGAEAA0A0BA
    • CPS92E-MA7PHH5
    • CPS92E-IA7PHH2
    • CPS41E-IA7BSB4
    • 10D25-7LGA1AA0A0BA
    • CPS92E-MA7PHH4
    • CPS41E-BA7ASB4

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2023 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.