• Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Bromberg, Staudt & Co. GmbH

  • Home
  • About us
  • Our services
  • Industries
  • Brands
    • Endress+Hauser
  • Contacts
  • EnglishEnglish
    • EspañolEspañol
    • TagalogTagalog
    • 한국어한국어
    • 中文 (中国)中文 (中国)
    • DeutschDeutsch
Home / Endress+Hauser / E+H Analytics / CA72TOC

Endress + Hauser CA72TOC - High temperature TOC analyzer - monitoring of industrial wastewater

ENDRESS + HAUSER Ammonium analyzer Liquiline System CA72TOC

Endress + Hauser CA72TOC determines the total organic carbon (TOC) content in a number of industries. It measures reliably and accurately even in heavy duty applications with high loads of salt, fat or fibers.
Analyzer for online-determination of TOC in aqueous media using thermic catalytic combustion

Endress + Hauser CA72TOC measuring principle:

UV photometric

Endress + Hauser CA72TOC measuring range:

0.25 to 600 mg TOC/l
1 to 2400 mg TOC/l
2.5 to 6000 mg TOC/l
5 to 12000 mg TOC/l
With the optional pre-dilution the measuring range will expand by the factor of 20

Endress + Hauser CA72TOC application:

CA72TOC monitors and controls:
• Industrial discharge
• Inlets of wastewater treatment plants
• Outlets of wastewater treatment plants
• Process water
• Surface run-off

Endress + Hauser CA72TOC advantages:

• Process optimization: Constant safeguard against product losses.
• Cost savings: 2-channel version offers an excellent price-performance ratio.
• Reliable discharge monitoring: Configuration for fat and grease, low pH values and organic acids.
• Improved process stability and safety: Immediate readjustment of the process based on online information.
• Robust design: Self-cleaning slit filter and automatic backflush function support long maintenance intervals.
• Safe and convenient operation: Remote access and diagnostics via serial interface.

Endress + Hauser CA72TOC process temperature:

0 to 40 °C (32 to 104 °F)

Endress + Hauser CA72TOC Process pressure:

Pressure free

Endress + Hauser CA72TOC Sample flow rate:

20 ml/min (0.32 US gal/hr)

CA72TOC-D2A2E2

© E+H TOC analyzer CA72TOC-D2A2E2

Endress + Hauser CA72TOC-D2A2E2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QA9/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D2A2E2

CA72TOC-C1A1A2

© E+H TOC analyzer CA72TOC-C1A1A2

Endress + Hauser CA72TOC-C1A1A2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-2UD2/0 Endress Hauser CA 72TOC C Measuring range; Adjustable: 2,5-6000 mg/l … [Read more...] about CA72TOC-C1A1A2

CA72TOC-A3A0F2

© E+H TOC analyzer CA72TOC-A3A0F2

Endress + Hauser CA72TOC-A3A0F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6Q06/0 Endress Hauser CA 72TOC A Measuring range; Adjustable: 0,25-600 mg/l … [Read more...] about CA72TOC-A3A0F2

CA72TOC-C3A0F2

© E+H TOC analyzer CA72TOC-C3A0F2

Endress + Hauser CA72TOC-C3A0F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-69L2/0 Endress Hauser CA 72TOC C Measuring range; Adjustable: 2,5-6000 mg/l … [Read more...] about CA72TOC-C3A0F2

CA72TOC-C1A2C2

© E+H TOC analyzer CA72TOC-C1A2C2

Endress + Hauser CA72TOC-C1A2C2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6Q74/0 Endress Hauser CA 72TOC C Measuring range; Adjustable: 2,5-6000 mg/l … [Read more...] about CA72TOC-C1A2C2

CA72TOC-A3A1F2

© E+H TOC analyzer CA72TOC-A3A1F2

Endress + Hauser CA72TOC-A3A1F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6Q48/0 Endress Hauser CA 72TOC A Measuring range; Adjustable: 0,25-600 mg/l … [Read more...] about CA72TOC-A3A1F2

CA72TOC-B2A2E2

© E+H TOC analyzer CA72TOC-B2A2E2

Endress + Hauser CA72TOC-B2A2E2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-4DX0/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B2A2E2

CA72TOC-D3A2E2

© E+H TOC analyzer CA72TOC-D3A2E2

Endress + Hauser CA72TOC-D3A2E2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QF6/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D3A2E2

CA72TOC-D3A1F2

© E+H TOC analyzer CA72TOC-D3A1F2

Endress + Hauser CA72TOC-D3A1F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-63F8/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D3A1F2

CA72TOC-A1A3C2

© E+H TOC analyzer CA72TOC-A1A3C2

Endress + Hauser CA72TOC-A1A3C2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-5K80/0 Endress Hauser CA 72TOC A Measuring range; Adjustable: 0,25-600 mg/l … [Read more...] about CA72TOC-A1A3C2

CA72TOC-D1A1A2

© E+H TOC analyzer CA72TOC-D1A1A2

Endress + Hauser CA72TOC-D1A1A2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-13M4/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D1A1A2

CA72TOC-B1A3C2

© E+H TOC analyzer CA72TOC-B1A3C2

Endress + Hauser CA72TOC-B1A3C2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6FU1/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B1A3C2

CA72TOC-A2A2E2

© E+H TOC analyzer CA72TOC-A2A2E2

Endress + Hauser CA72TOC-A2A2E2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-5763/0 Endress Hauser CA 72TOC A Measuring range; Adjustable: 0,25-600 mg/l … [Read more...] about CA72TOC-A2A2E2

CA72TOC-B3A2E2

© E+H TOC analyzer CA72TOC-B3A2E2

Endress + Hauser CA72TOC-B3A2E2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QD5/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B3A2E2

CA72TOC-B2A1F2

© E+H TOC analyzer CA72TOC-B2A1F2

Endress + Hauser CA72TOC-B2A1F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6Q27/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B2A1F2

CA72TOC-B2A4D2

© E+H TOC analyzer CA72TOC-B2A4D2

Endress + Hauser CA72TOC-B2A4D2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QK3/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B2A4D2

CA72TOC-D2A0F2

© E+H TOC analyzer CA72TOC-D2A0F2

Endress + Hauser CA72TOC-D2A0F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-5ND6/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D2A0F2

CA72TOC-D2A4D2

© E+H TOC analyzer CA72TOC-D2A4D2

Endress + Hauser CA72TOC-D2A4D2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QM4/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D2A4D2

CA72TOC-C2A0F2

© E+H TOC analyzer CA72TOC-C2A0F2

Endress + Hauser CA72TOC-C2A0F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-4LE2/0 Endress Hauser CA 72TOC C Measuring range; Adjustable: 2,5-6000 mg/l … [Read more...] about CA72TOC-C2A0F2

CA72TOC-B1A2C2

© E+H TOC analyzer CA72TOC-B1A2C2

Endress + Hauser CA72TOC-B1A2C2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6Q69/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B1A2C2

CA72TOC-B3A4D2

© E+H TOC analyzer CA72TOC-B3A4D2

Endress + Hauser CA72TOC-B3A4D2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QP0/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B3A4D2

CA72TOC-A3A2E2

© E+H TOC analyzer CA72TOC-A3A2E2

Endress + Hauser CA72TOC-A3A2E2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QC0/0 Endress Hauser CA 72TOC A Measuring range; Adjustable: 0,25-600 mg/l … [Read more...] about CA72TOC-A3A2E2

CA72TOC-D1A0A2

© E+H TOC analyzer CA72TOC-D1A0A2

Endress + Hauser CA72TOC-D1A0A2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-18M2/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D1A0A2

CA72TOC-C3A1F2

© E+H TOC analyzer CA72TOC-C3A1F2

Endress + Hauser CA72TOC-C3A1F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6KP2/0 Endress Hauser CA 72TOC C Measuring range; Adjustable: 2,5-6000 mg/l … [Read more...] about CA72TOC-C3A1F2

CA72TOC-C3A2E2

© E+H TOC analyzer CA72TOC-C3A2E2

Endress + Hauser CA72TOC-C3A2E2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QE0/0 Endress Hauser CA 72TOC C Measuring range; Adjustable: 2,5-6000 mg/l … [Read more...] about CA72TOC-C3A2E2

CA72TOC-D3A4D2

© E+H TOC analyzer CA72TOC-D3A4D2

Endress + Hauser CA72TOC-D3A4D2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6DW9/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D3A4D2

CA72TOC-A3A4D2

© E+H TOC analyzer CA72TOC-A3A4D2

Endress + Hauser CA72TOC-A3A4D2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QN0/0 Endress Hauser CA 72TOC A Measuring range; Adjustable: 0,25-600 mg/l … [Read more...] about CA72TOC-A3A4D2

CA72TOC-B3A0F2

© E+H TOC analyzer CA72TOC-B3A0F2

Endress + Hauser CA72TOC-B3A0F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QR1/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B3A0F2

CA72TOC-D2A1F2

© E+H TOC analyzer CA72TOC-D2A1F2

Endress + Hauser CA72TOC-D2A1F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6Q32/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D2A1F2

CA72TOC-A1A0A2

© E+H TOC analyzer CA72TOC-A1A0A2

Endress + Hauser CA72TOC-A1A0A2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection Endress Hauser CA 72TOC A Measuring range; Adjustable: 0,25-600 mg/l TOC 1 Sample … [Read more...] about CA72TOC-A1A0A2

  • Go to page 1
  • Go to page 2
  • Go to Next Page »

Primary Sidebar

Contact us:





    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • CM444R-CDM4BA1FK6
    • CPS16E-KA7ATA2
    • CPS16E-NA7ATA4
    • CPS16E-GR7BTA4
    • CM444R-CAM4BA5FA1
    • CPS16E-JA7ATA4
    • CPS92E-BA7PHH5+Z1
    • CPS16E-CB7ATA4
    • CPS92E-UA7PHH4+Z1
    • CPS41E-NA7ASC5
    • 10D25-3TGA1AA0A0BA
    • CPS92E-UA7PHH2+Z1
    • CPS41E-JA7BSB4
    • 10D25-6VGAEAA0A0BA
    • CPS92E-MA7PHH5
    • CPS92E-IA7PHH2
    • CPS41E-IA7BSB4
    • 10D25-7LGA1AA0A0BA
    • CPS92E-MA7PHH4
    • CPS41E-BA7ASB4

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2023 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.