Endress + Hauser CA72TOC - High temperature TOC analyzer - monitoring of industrial wastewater

ENDRESS + HAUSER Ammonium analyzer Liquiline System CA72TOC

Endress + Hauser CA72TOC determines the total organic carbon (TOC) content in a number of industries. It measures reliably and accurately even in heavy duty applications with high loads of salt, fat or fibers.
Analyzer for online-determination of TOC in aqueous media using thermic catalytic combustion

Endress + Hauser CA72TOC measuring principle:

UV photometric

Endress + Hauser CA72TOC measuring range:

0.25 to 600 mg TOC/l
1 to 2400 mg TOC/l
2.5 to 6000 mg TOC/l
5 to 12000 mg TOC/l
With the optional pre-dilution the measuring range will expand by the factor of 20

Endress + Hauser CA72TOC application:

CA72TOC monitors and controls:
• Industrial discharge
• Inlets of wastewater treatment plants
• Outlets of wastewater treatment plants
• Process water
• Surface run-off

Endress + Hauser CA72TOC advantages:

• Process optimization: Constant safeguard against product losses.
• Cost savings: 2-channel version offers an excellent price-performance ratio.
• Reliable discharge monitoring: Configuration for fat and grease, low pH values and organic acids.
• Improved process stability and safety: Immediate readjustment of the process based on online information.
• Robust design: Self-cleaning slit filter and automatic backflush function support long maintenance intervals.
• Safe and convenient operation: Remote access and diagnostics via serial interface.

Endress + Hauser CA72TOC process temperature:

0 to 40 °C (32 to 104 °F)

Endress + Hauser CA72TOC Process pressure:

Pressure free

Endress + Hauser CA72TOC Sample flow rate:

20 ml/min (0.32 US gal/hr)

CA72TOC-D2A2E2

© E+H TOC analyzer CA72TOC-D2A2E2

Endress + Hauser CA72TOC-D2A2E2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QA9/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D2A2E2

CA72TOC-C1A1A2

© E+H TOC analyzer CA72TOC-C1A1A2

Endress + Hauser CA72TOC-C1A1A2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-2UD2/0 Endress Hauser CA 72TOC C Measuring range; Adjustable: 2,5-6000 mg/l … [Read more...] about CA72TOC-C1A1A2

CA72TOC-A3A0F2

© E+H TOC analyzer CA72TOC-A3A0F2

Endress + Hauser CA72TOC-A3A0F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6Q06/0 Endress Hauser CA 72TOC A Measuring range; Adjustable: 0,25-600 mg/l … [Read more...] about CA72TOC-A3A0F2

CA72TOC-C3A0F2

© E+H TOC analyzer CA72TOC-C3A0F2

Endress + Hauser CA72TOC-C3A0F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-69L2/0 Endress Hauser CA 72TOC C Measuring range; Adjustable: 2,5-6000 mg/l … [Read more...] about CA72TOC-C3A0F2

CA72TOC-C1A2C2

© E+H TOC analyzer CA72TOC-C1A2C2

Endress + Hauser CA72TOC-C1A2C2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6Q74/0 Endress Hauser CA 72TOC C Measuring range; Adjustable: 2,5-6000 mg/l … [Read more...] about CA72TOC-C1A2C2

CA72TOC-A3A1F2

© E+H TOC analyzer CA72TOC-A3A1F2

Endress + Hauser CA72TOC-A3A1F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6Q48/0 Endress Hauser CA 72TOC A Measuring range; Adjustable: 0,25-600 mg/l … [Read more...] about CA72TOC-A3A1F2

CA72TOC-B2A2E2

© E+H TOC analyzer CA72TOC-B2A2E2

Endress + Hauser CA72TOC-B2A2E2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-4DX0/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B2A2E2

CA72TOC-D3A2E2

© E+H TOC analyzer CA72TOC-D3A2E2

Endress + Hauser CA72TOC-D3A2E2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QF6/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D3A2E2

CA72TOC-D3A1F2

© E+H TOC analyzer CA72TOC-D3A1F2

Endress + Hauser CA72TOC-D3A1F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-63F8/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D3A1F2

CA72TOC-A1A3C2

© E+H TOC analyzer CA72TOC-A1A3C2

Endress + Hauser CA72TOC-A1A3C2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-5K80/0 Endress Hauser CA 72TOC A Measuring range; Adjustable: 0,25-600 mg/l … [Read more...] about CA72TOC-A1A3C2

CA72TOC-D1A1A2

© E+H TOC analyzer CA72TOC-D1A1A2

Endress + Hauser CA72TOC-D1A1A2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-13M4/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D1A1A2

CA72TOC-B1A3C2

© E+H TOC analyzer CA72TOC-B1A3C2

Endress + Hauser CA72TOC-B1A3C2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6FU1/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B1A3C2

CA72TOC-A2A2E2

© E+H TOC analyzer CA72TOC-A2A2E2

Endress + Hauser CA72TOC-A2A2E2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-5763/0 Endress Hauser CA 72TOC A Measuring range; Adjustable: 0,25-600 mg/l … [Read more...] about CA72TOC-A2A2E2

CA72TOC-B3A2E2

© E+H TOC analyzer CA72TOC-B3A2E2

Endress + Hauser CA72TOC-B3A2E2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QD5/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B3A2E2

CA72TOC-B2A1F2

© E+H TOC analyzer CA72TOC-B2A1F2

Endress + Hauser CA72TOC-B2A1F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6Q27/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B2A1F2

CA72TOC-B2A4D2

© E+H TOC analyzer CA72TOC-B2A4D2

Endress + Hauser CA72TOC-B2A4D2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QK3/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B2A4D2

CA72TOC-D2A0F2

© E+H TOC analyzer CA72TOC-D2A0F2

Endress + Hauser CA72TOC-D2A0F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-5ND6/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D2A0F2

CA72TOC-D2A4D2

© E+H TOC analyzer CA72TOC-D2A4D2

Endress + Hauser CA72TOC-D2A4D2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QM4/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D2A4D2

CA72TOC-C2A0F2

© E+H TOC analyzer CA72TOC-C2A0F2

Endress + Hauser CA72TOC-C2A0F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-4LE2/0 Endress Hauser CA 72TOC C Measuring range; Adjustable: 2,5-6000 mg/l … [Read more...] about CA72TOC-C2A0F2

CA72TOC-B1A2C2

© E+H TOC analyzer CA72TOC-B1A2C2

Endress + Hauser CA72TOC-B1A2C2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6Q69/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B1A2C2

CA72TOC-B3A4D2

© E+H TOC analyzer CA72TOC-B3A4D2

Endress + Hauser CA72TOC-B3A4D2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QP0/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B3A4D2

CA72TOC-A3A2E2

© E+H TOC analyzer CA72TOC-A3A2E2

Endress + Hauser CA72TOC-A3A2E2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QC0/0 Endress Hauser CA 72TOC A Measuring range; Adjustable: 0,25-600 mg/l … [Read more...] about CA72TOC-A3A2E2

CA72TOC-D1A0A2

© E+H TOC analyzer CA72TOC-D1A0A2

Endress + Hauser CA72TOC-D1A0A2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-18M2/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D1A0A2

CA72TOC-C3A1F2

© E+H TOC analyzer CA72TOC-C3A1F2

Endress + Hauser CA72TOC-C3A1F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6KP2/0 Endress Hauser CA 72TOC C Measuring range; Adjustable: 2,5-6000 mg/l … [Read more...] about CA72TOC-C3A1F2

CA72TOC-C3A2E2

© E+H TOC analyzer CA72TOC-C3A2E2

Endress + Hauser CA72TOC-C3A2E2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QE0/0 Endress Hauser CA 72TOC C Measuring range; Adjustable: 2,5-6000 mg/l … [Read more...] about CA72TOC-C3A2E2

CA72TOC-D3A4D2

© E+H TOC analyzer CA72TOC-D3A4D2

Endress + Hauser CA72TOC-D3A4D2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6DW9/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D3A4D2

CA72TOC-A3A4D2

© E+H TOC analyzer CA72TOC-A3A4D2

Endress + Hauser CA72TOC-A3A4D2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QN0/0 Endress Hauser CA 72TOC A Measuring range; Adjustable: 0,25-600 mg/l … [Read more...] about CA72TOC-A3A4D2

CA72TOC-B3A0F2

© E+H TOC analyzer CA72TOC-B3A0F2

Endress + Hauser CA72TOC-B3A0F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6QR1/0 Endress Hauser CA 72TOC B Measuring range; Adjustable: 1-2400 mg/l … [Read more...] about CA72TOC-B3A0F2

CA72TOC-D2A1F2

© E+H TOC analyzer CA72TOC-D2A1F2

Endress + Hauser CA72TOC-D2A1F2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection CA72TOC-6Q32/0 Endress Hauser CA 72TOC D Measuring range; Adjustable: 5-12000 mg/l … [Read more...] about CA72TOC-D2A1F2

CA72TOC-A1A0A2

© E+H TOC analyzer CA72TOC-A1A0A2

Endress + Hauser CA72TOC-A1A0A2 online high temperature TOC analyzer for aqueous solutions. High temperature method with catalytic oxidation. Detection of CO2: Non dispersive infrared detection Endress Hauser CA 72TOC A Measuring range; Adjustable: 0,25-600 mg/l TOC 1 Sample … [Read more...] about CA72TOC-A1A0A2

  • Page 1
  • Page 2
  • Go to Next Page »

Primary Sidebar

Contact us:





    What is 3 + 9

    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • TM131-U4AAAFA2AA3AAAB0AA1AA1
    • TM131-URAAAFA2AA3AAAB0AA1AA1
    • TM131-U5AAAFA2AA3AAAB0AA1AA1
    • TM131-8FAAAFA2AA3AAAB0AA1AA1
    • TM131-URAAAFA2AA2AAAB0AA1AA1
    • TM131-U4AAAFA2AA2AAAB0AA1AA1
    • TM131-8FAAAFA1AA3AAAB0AA1AA1
    • TM131-AAAAAFA1AA4AAAB0AA1AA1
    • TM131-G4AAAFA1AA8AAAB0AA1AA1
    • TM131-84AAAFA2AA2AAAB0AA1AA1
    • TM131-CGAAAFA2AA3AAAB0AA1AA1
    • TM131-GFAAAFA2AA3AAAB0AA1AA1
    • TM121-GRHBB1A6BC1A3A1
    • TM131-GJAAAFA1AA5AAAB0AA1AA1
    • TM131-MAAAAFA1AA8AAAB0AA1AA1
    • TM121-AAACB1A4BA1A3A1
    • TM111-MAAABA1BBB0AA1AA1
    • TM111-U5ABAA1BBB0AA1AA1
    • TM121-URA4BA1A3A1
    • TM131-NFAAAFA1AA4AAAB0AA1AA1

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2025 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.