• Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Bromberg, Staudt & Co. GmbH

  • Home
  • About us
  • Our services
  • Industries
  • Brands
    • Endress+Hauser
  • Contacts
  • EnglishEnglish
    • EspañolEspañol
    • TagalogTagalog
    • 한국어한국어
    • 中文 (中国)中文 (中国)
    • DeutschDeutsch
Home / Endress+Hauser / E+H Flow measurement / Promag 10D

Endress + Hauser Proline Promag 10D electromagnetic flowmeter basic unit for non spacious application in water industry

ENDRESS + HAUSER Proline Promag 10D electromagnetic flowmeter

Endress + Hauser Proline Promag 10D electromagnetic flowmeter basic unit for non spacious application in water industry. Highly cost-effective flowmeter, available as compact wafer. Easy and fast centering of the sensor – innovative housing construction. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction.

Endress + Hauser Proline Promag 10D electromagnetic flowmeter measuring principle:


Electromagnetic

Endress + Hauser Proline Promag 10D electromagnetic flowmeter measured values:


Volume flow

Endress + Hauser Proline Promag 10D electromagnetic flowmeter measuring range:


9 to 4700 dm3/min (2.5 to 1250 gal/min)

Endress + Hauser Proline Promag 10D electromagnetic flowmeter nominal diameter range:


DN 25 to 100 (1 to 4")

Endress + Hauser Proline Promag 10D electromagnetic flowmeter application:

• The measuring principle is virtually independent of pressure, density, temperature and viscosity
• For basic water applications; optimized for limited space and plastic pipe installations.

Device properties
• Short installation length and low weight
• Integrated ground disks made of stainless steel
• International drinking water approvals
• 2‐line display with push buttons
• Device in compact or remote version
• HART

Endress + Hauser Proline Promag 10D electromagnetic flowmeter advantages are:

• Easy, fast centering of the sensor – innovative housing construction
• Energy-saving flow measurement – no pressure loss due to cross-section constriction
• Cost-effective – designed for easy applications and direct integration
• Safe operation – display provides easy readable process information
• Fully industry compliant – IEC/EN/NAMUR
• Maintenance-free – no moving parts

Endress + Hauser Proline Promag 10D electromagnetic flowmeter medium process temperature:


0 to +60 °C (+32 to +140 °F)

Endress + Hauser Proline Promag 10D electromagnetic flowmeter ambient temperature:


–20 to +60 °C (–4 to +140 °F)

Endress + Hauser Proline Promag 10D electromagnetic flowmeter process pressure:


PN 16, Class 150, 10K

Endress + Hauser Proline Promag 10D electromagnetic flowmeter power supply:


DC 11 to 40 V
AC 85 to 250 V (45 to 65 Hz)
AC 20 to 28 V (45 to 65 Hz)

Endress + Hauser Proline Promag 10D electromagnetic flowmeter outputs:


• 4‐20 mA HART (active)
• Pulse/switch output (passive)


10D25-6CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D25-6CGA1AA0A4AA+M1

Endress + Hauser 10D25-6CGA1AA0A4AA+M1 Electromagnetic flowmeter 10D25-1CL3/115 Endress Hauser 10 D25 6 Liner: Polyamide, ACS Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D25-6CGA1AA0A4AA+M1

10D50-6CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D50-6CGA1AA0A4AA+M1

Endress + Hauser 10D50-6CGA1AA0A4AA+M1 Electromagnetic flowmeter 10D50-1A19/101 Endress Hauser 10 D50 6 Liner: Polyamide, ACS Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D50-6CGA1AA0A4AA+M1

10D80-5CGA1AA0A5AA+M1

© E+H electromagnetic flowmeter Promag 10D40-5CGA1AA0A5AA+M1

Endress + Hauser 10D80-5CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D80-12C6/101 Endress Hauser 10 D80 5 Liner: Polyamide, KTW/W270 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D80-5CGA1AA0A5AA+M1

10D25-3CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D25-3CGA1AA0A4AA+M1

Endress + Hauser 10D25-3CGA1AA0A4AA+M1 Electromagnetic flowmeter Endress Hauser 10 D25 3 Liner: Polyamide C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, certificate: w/o A Approval: Non-hazardous … [Read more...] about 10D25-3CGA1AA0A4AA+M1

10D65-6CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D65-6CGA1AA0A4AA+M1

Endress + Hauser 10D65-6CGA1AA0A4AA+M1 Electromagnetic flowmeter 10D65-12H3/101 Endress Hauser 10 D65 6 Liner: Polyamide, ACS Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D65-6CGA1AA0A4AA+M1

10D65-3CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D65-3CGA1AA0A4AA+M1

Endress + Hauser 10D65-3CGA1AA0A4AA+M1 Electromagnetic flowmeter 10D65-1082/125 Endress Hauser 10 D65 3 Liner: Polyamide C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, certificate: w/o A Approval: … [Read more...] about 10D65-3CGA1AA0A4AA+M1

10D80-6CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D80-6CGA1AA0A4AA+M1

Endress + Hauser 10D80-6CGA1AA0A4AA+M1 Electromagnetic flowmeter 10D80-1779/101 Endress Hauser 10 D80 6 Liner: Polyamide, ACS Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D80-6CGA1AA0A4AA+M1

10D25-6CGA1AA0A5AA+M1

© E+H electromagnetic flowmeter Promag 10D25-6CGA1AA0A5AA+M1

Endress + Hauser 10D25-6CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D25-1CN4/101 Endress Hauser 10 D25 6 Liner: Polyamide, ACS Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D25-6CGA1AA0A5AA+M1

10D1H-5CGA1AA0A5AA+M1

© E+H electromagnetic flowmeter Promag 10D1H-5CGA1AA0A5AA+M1

Endress + Hauser 10D1H-5CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D1H-10W1/101 Endress Hauser 10 D1H 5 Liner: Polyamide, KTW/W270 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D1H-5CGA1AA0A5AA+M1

10D40-6CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D40-6CGA1AA0A4AA+M1

Endress + Hauser 10D40-6CGA1AA0A4AA+M1 Electromagnetic flowmeter 10D40-1830/101 Endress Hauser 10 D40 6 Liner: Polyamide, ACS Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D40-6CGA1AA0A4AA+M1

10D40-6CGA1AA0A5AA+M1

© E+H electromagnetic flowmeter Promag 10D40-6CGA1AA0A5AA+M1

Endress + Hauser 10D40-6CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D40-1H73/101 Endress Hauser 10 D40 6 Liner: Polyamide, ACS Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D40-6CGA1AA0A5AA+M1

10D50-6CGA1AA0A5AA+M1

© E+H Caudalímetro electromagnético Promag 10D50-6CGA1AA0A5AA+M1

Endress + Hauser 10D50-6CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D50-1Q51/101 Endress Hauser 10 D50 6 Liner: Polyamide, ACS Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D50-6CGA1AA0A5AA+M1

10D65-6CGA1AA0A5AA+M1

© E+H electromagnetic flowmeter Promag 10D65-6CGA1AA0A5AA+M1

Endress + Hauser 10D65-6CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D65-13N0/115 Endress Hauser 10 D65 6 Liner: Polyamide, ACS Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D65-6CGA1AA0A5AA+M1

10D40-7CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D40-7CGA1AA0A4AA+M1

Endress + Hauser 10D40-7CGA1AA0A4AA+M1 Electromagnetic flowmeter 10D40-1587/101 Endress Hauser 10 D40 7 Liner: Polyamide, WRAS BS6920 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional … [Read more...] about 10D40-7CGA1AA0A4AA+M1

10D1H-6CGA1AA0A5AA+M1

© E+H electromagnetic flowmeter Promag 10D1H-6CGA1AA0A5AA+M1

Endress + Hauser 10D1H-6CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D1H-1AC7/101 Endress Hauser 10 D1H 6 Liner: Polyamide, ACS Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D1H-6CGA1AA0A5AA+M1

10D80-6CGA1AA0A5AA+M1

© E+H electromagnetic flowmeter Promag 10D80-6CGA1AA0A5AA+M1

Endress + Hauser 10D80-6CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D80-1QM2/101 Endress Hauser 10 D80 6 Liner: Polyamide, ACS Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D80-6CGA1AA0A5AA+M1

10D50-7CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D50-7CGA1AA0A4AA+M1

Endress + Hauser 10D50-7CGA1AA0A4AA+M1 Electromagnetic flowmeter 10D50-1J02/101 Endress Hauser 10 D50 7 Liner: Polyamide, WRAS BS6920 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional … [Read more...] about 10D50-7CGA1AA0A4AA+M1

10D25-7CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D25-7CGA1AA0A4AA+M1

Endress + Hauser 10D25-7CGA1AA0A4AA+M1 Electromagnetic flowmeter 10D25-1RH9/101 Endress Hauser 10 D25 7 Liner: Polyamide, WRAS BS6920 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional … [Read more...] about 10D25-7CGA1AA0A4AA+M1

10D40-3CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D40-3CGA1AA0A4AA+M1

Endress + Hauser 10D40-3CGA1AA0A4AA+M1 Electromagnetic flowmeter 10D40-1040/101 Endress Hauser 10 D40 3 Liner: Polyamide C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, certificate: w/o A Approval: … [Read more...] about 10D40-3CGA1AA0A4AA+M1

10D65-7CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D65-7CGA1AA0A4AA+M1

Endress + Hauser 10D65-7CGA1AA0A4AA+M1 Electromagnetic flowmeter 10D65-1550/101 Endress Hauser 10 D65 7 Liner: Polyamide, WRAS BS6920 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional … [Read more...] about 10D65-7CGA1AA0A4AA+M1

10D40-7CGA1AA0A5AA+M1

© E+H electromagnetic flowmeter Promag 10D40-7CGA1AA0A5AA+M1

Endress + Hauser 10D40-7CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D40-1FK5/101 Endress Hauser 10 D40 7 Liner: Polyamide, WRAS BS6920 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional … [Read more...] about 10D40-7CGA1AA0A5AA+M1

10D50-7CGA1AA0A5AA+M1

© E+H electromagnetic flowmeter Promag 10D50-7CGA1AA0A5AA+M1

Endress + Hauser 10D50-7CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D50-1HH6/101 Endress Hauser 10 D50 7 Liner: Polyamide, WRAS BS6920 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional … [Read more...] about 10D50-7CGA1AA0A5AA+M1

10D25-7CGA1AA0A5AA+M1

© E+H electromagnetic flowmeter Promag 10D25-7CGA1AA0A5AA+M1

Endress + Hauser 10D25-7CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D25-1A24/101 Endress Hauser 10 D25 7 Liner: Polyamide, WRAS BS6920 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional … [Read more...] about 10D25-7CGA1AA0A5AA+M1

10D65-7CGA1AA0A5AA+M1

© E+H electromagnetic flowmeter Promag 10D65-7CGA1AA0A5AA+M1

Endress + Hauser 10D65-7CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D65-1EE2/101 Endress Hauser 10 D65 7 Liner: Polyamide, WRAS BS6920 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional … [Read more...] about 10D65-7CGA1AA0A5AA+M1

10D80-7CGA1AA0A5AA+M1

© E+H electromagnetic flowmeter Promag 10D80-7CGA1AA0A5AA+M1

Endress + Hauser 10D80-7CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D80-1JJ4/101 Endress Hauser 10 D80 7 Liner: Polyamide, WRAS BS6920 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional … [Read more...] about 10D80-7CGA1AA0A5AA+M1

10D80-7CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D80-7CGA1AA0A4AA+M1

Endress + Hauser 10D80-7CGA1AA0A4AA+M1 Electromagnetic flowmeter 10D80-1CP5/101 Endress Hauser 10 D80 7 Liner: Polyamide, WRAS BS6920 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional … [Read more...] about 10D80-7CGA1AA0A4AA+M1

10D80-4CGA1AA0A5AA+M1

© E+H electromagnetic flowmeter Promag 10D80-4CGA1AA0A5AA+M1

Endress + Hauser 10D80-4CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D80-1DU6/101 Endress Hauser 10 D80 4 Liner: Polyamide, NSF 61 Drinking- + warm water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional … [Read more...] about 10D80-4CGA1AA0A5AA+M1

10D80-3CGA1AA0A5AA+M1

© E+H electromagnetic flowmeter Promag 10D80-3CGA1AA0A5AA+M1

Endress + Hauser 10D80-3CGA1AA0A5AA+M1 Electromagnetic flowmeter 10D80-1291/101 Endress Hauser 10 D80 3 Liner: Polyamide C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, certificate: w/o A Approval: … [Read more...] about 10D80-3CGA1AA0A5AA+M1

10D80-5CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D80-5CGA1AA0A4AA+M1

Endress + Hauser 10D80-5CGA1AA0A4AA+M1 Electromagnetic flowmeter 10D80-10X7/101 Endress Hauser 10 D80 5 Liner: Polyamide, KTW/W270 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D80-5CGA1AA0A4AA+M1

10D65-5CGA1AA0A4AA+M1

© E+H electromagnetic flowmeter Promag 10D65-5CGA1AA0A4AA+M1

Endress + Hauser 10D65-5CGA1AA0A4AA+M1 Electromagnetic flowmeter 10D65-1009/101 Endress Hauser 10 D65 5 Liner: Polyamide, KTW/W270 Drinking water approval C Process Connection: PN16, EN1092-1 (DIN2501) G Electrodes: 14435/316L bullet nose A Calibration: 05% 1 Additional Test, … [Read more...] about 10D65-5CGA1AA0A4AA+M1

  • Go to page 1
  • Go to page 2
  • Go to Next Page »

Primary Sidebar

Contact us:





    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • CLM223-CS8605
    • FMP52-BLAABACAAEK
    • CLD134-SSMS50AA1
    • CLS16D-3E1RG
    • NRF81-AA1BE1A1B2BAFICR
    • NRF81-IA2BA1X0B2BAEPTC
    • FMP52-FAAAAACAAEK
    • CLD134-WSMS40AA1
    • CLS16D-4F1UG
    • FTW23-AA7NWSJ
    • NRF81-FD1BE1A1B2BAFICR
    • FMP50-MAAACBAAA1RDJ
    • FMP52-BGAABACAAEK
    • FMP56-C2AABBLAABGDE
    • CLD134-PVA450AA1
    • CLS16D-3G1SG
    • FMP54-I3AABBAED2ABJ
    • FTW23-AA4NWSJ
    • NRF81-FD2BB1A2B1AAENTC
    • FTW23-AA4MX2J

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2021 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.