Endress + Hauser CPS16D-7BT6C pH / ORP- combined electrode, Memosens functionality, Diaphragm PTFE, Reference Gel, Signal transmission digital, temperatur sensor integrated, ORP platinum electrode CPS16D-1457/0 Endress Hauser CPS 16D 7 Version: Basic version BT Application … [Read more...] about CPS16D-7BT6C
Endress + Hauser Analytics
Endress + Hauser CA72TOC -TOC analyzer
TURBIMAX CUS SENSORS FOR TURBIDITY MEASUREMENT
Process analytical technology pharmaceutical industry
CPS71D-7TU2C
Endress + Hauser CPS71D-7TU2C pH comb. electrode, Memosens functionality Signal transmission: Digital Diaphragm: Ceramic Reference system: Gel (non acrylamide), Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min … [Read more...] about CPS71D-7TU2C
CLS16D-4F1UO
Endress + Hauser CLS16D-4F1UO Conductivity, 2-electrode sensor Memosens functionality hygienic design, EHEDG Life Science, Water (Utilities) * Ultrapure / Pure Water * Water for Injection (WFI) * Water Measurement range 0,04 - 500 uS/cm Stainless steel 1.4435 (316L), FFKM FDA, … [Read more...] about CLS16D-4F1UO
CPS71D-7TC2G
Endress + Hauser CPS71D-7TC2G pH comb. electrode, Memosens functionality Signal transmission: Digital Diaphragm: Ceramic Reference system: Gel (non acrylamide), Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min … [Read more...] about CPS71D-7TC2G
CPS71D-7TU5G
Endress + Hauser CPS71D-7TU5G pH comb. electrode, Memosens functionality Signal transmission: Digital Diaphragm: Ceramic Reference system: Gel (non acrylamide), Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min … [Read more...] about CPS71D-7TU5G
CPS71D-7TU5K
Endress + Hauser CPS71D-7TU5K pH comb. electrode, Memosens functionality Signal transmission: Digital Diaphragm: Ceramic Reference system: Gel (non acrylamide), Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min … [Read more...] about CPS71D-7TU5K
CPA510-0224
Endress + Hauser CPA510-0224 Immersion assembly Electrode: 1x, 120mm, PG 13,5 Application: flow channel, tanks bassin Sensor fitting: Bajonet, PPS Endress Hauser CPA 510 0 Immersion Depth: 1000mm 22 Assembly Material; Seal: PVDF; O-ring Viton + electrode holder PPS 4 Process … [Read more...] about CPA510-0224
CPS71D-7TU5V
Endress + Hauser CPS71D-7TU5V pH comb. electrode, Memosens functionality Signal transmission: Digital Diaphragm: Ceramic Reference system: Gel (non acrylamide), Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min … [Read more...] about CPS71D-7TU5V
CCS51-AA11BF01+NDZ1
Endress + Hauser CCS51-AA11BF01+NDZ1 (25 mm diameter) amperometric, membrane-covered sensor Reliable disinfection for drinking and pool water, safety in food industry and utilities low-maintenance sensor, broad measuring range: 0 - 20 mg/l free chlorine long-time stable measurement, … [Read more...] about CCS51-AA11BF01+NDZ1
OUSAF12-G0C0B
Endress + Hauser OUSAF12-G0C0B Color and NIR absorbance sensor, wavelength range 400-1500 nm Measuring range: up to 50 OD (depending on OPL) Light source: Low wattage incandescent lamp Endress Hauser OUSAF 12 G Wavelength: 1134 nm 0 Calibration/validation: Standard C Lamp: … [Read more...] about OUSAF12-G0C0B
CPS41D-7AB4AV
Endress + Hauser CPS41D-7AB4AV pH-comb. electrode, Diaphragm: Ceramic Memosens functionality Reference: liquid Working limit: max. 10 bar Endress Hauser CPS 41D 7 Version: Basic version AB Application Range: 1-12pH; -15-80oC; 1 Diaphr. 4 Shaft length: 225 mm A Electrolyte … [Read more...] about CPS41D-7AB4AV
OUSAF11-AA105B3A15A
Endress + Hauser OUSAF11-AA105B3A15A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2H00/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA105B3A15A
CCS51-AA11AD03+NB
Endress + Hauser CCS51-AA11AD03+NB (25 mm diameter) amperometric, membrane-covered sensor Reliable disinfection for drinking and pool water, safety in food industry and utilities low-maintenance sensor, broad measuring range: 0 - 20 mg/l free chlorine long-time stable measurement, … [Read more...] about CCS51-AA11AD03+NB
CCS51-AA11BF01+NC
Endress + Hauser CCS51-AA11BF01+NC (25 mm diameter) amperometric, membrane-covered sensor Reliable disinfection for drinking and pool water, safety in food industry and utilities low-maintenance sensor, broad measuring range: 0 - 20 mg/l free chlorine long-time stable measurement, … [Read more...] about CCS51-AA11BF01+NC
OUSAF12-D0D0B
Endress + Hauser OUSAF12-D0D0B Color and NIR absorbance sensor, wavelength range 400-1500 nm Measuring range: up to 50 OD (depending on OPL) Light source: Low wattage incandescent lamp Endress Hauser OUSAF 12 D Wavelength: 540 nm 0 Calibration/validation: Standard D Lamp: Gas … [Read more...] about OUSAF12-D0D0B
CCS51-AA11AD03+NBZ1
Endress + Hauser CCS51-AA11AD03+NBZ1 (25 mm diameter) amperometric, membrane-covered sensor Reliable disinfection for drinking and pool water, safety in food industry and utilities low-maintenance sensor, broad measuring range: 0 - 20 mg/l free chlorine long-time stable measurement, … [Read more...] about CCS51-AA11AD03+NBZ1
CPS441D-76B2G
Endress + Hauser CPS441D-76B2G pH-comb. electrode, ISFET-Technology Memosens functionality Signal transmission: Digital Diaphragm: Ceramic Reference: liquid Temp.-sensor: Pt1000 Material: PEEK Working limit: max.10 bar CPS441D-10C2/0 Endress Hauser CPS 441D 7 Version: basic … [Read more...] about CPS441D-76B2G
CCS51-AA11BF01+N9Z1
Endress + Hauser CCS51-AA11BF01+N9Z1 (25 mm diameter) amperometric, membrane-covered sensor Reliable disinfection for drinking and pool water, safety in food industry and utilities low-maintenance sensor, broad measuring range: 0 - 20 mg/l free chlorine long-time stable measurement, … [Read more...] about CCS51-AA11BF01+N9Z1
CCS51-AA11AD01+N9Z1
Endress + Hauser CCS51-AA11AD01+N9Z1 (25 mm diameter) amperometric, membrane-covered sensor Reliable disinfection for drinking and pool water, safety in food industry and utilities low-maintenance sensor, broad measuring range: 0 - 20 mg/l free chlorine long-time stable measurement, … [Read more...] about CCS51-AA11AD01+N9Z1
CPS16D-7BT61
Endress + Hauser CPS16D-7BT61 pH / ORP- combined electrode, Memosens functionality, Diaphragm PTFE, Reference Gel, Signal transmission digital, temperatur sensor integrated, ORP platinum electrode CPS16D-1061/0 Endress Hauser CPS 16D 7 Version: Basic version BT Application … [Read more...] about CPS16D-7BT61
CPS41D-7BC4AG
Endress + Hauser CPS41D-7BC4AG pH-comb. electrode, Diaphragm: Ceramic Memosens functionality Reference: liquid Working limit: max. 10 bar Endress Hauser CPS 41D 7 Version: Basic version BC Application Range: 0-14pH; 0-135oC; 3 Diaphr.; steril. 4 Shaft length: 225 mm … [Read more...] about CPS41D-7BC4AG
CPS41D-7AC6BC
Endress + Hauser CPS41D-7AC6BC pH-comb. electrode, Diaphragm: Ceramic Memosens functionality Reference: liquid Working limit: max. 10 bar Endress Hauser CPS 41D 7 Version: Basic version AC Application Range: 1-12pH; -15-80oC; 3 Diaphr. 6 Shaft length: 425 mm B Electrolyte … [Read more...] about CPS41D-7AC6BC
CPS16D-7AT2C+Z1
Endress + Hauser CPS16D-7AT2C+Z1 pH / ORP- combined electrode, Memosens functionality, Diaphragm PTFE, Reference Gel, Signal transmission digital, temperatur sensor integrated, ORP platinum electrode CPS16D-12W5/0 Endress Hauser CPS 16D 7 Version: Basic version AT Application … [Read more...] about CPS16D-7AT2C+Z1
CCS51-AA11BF01+Z1
Endress + Hauser CCS51-AA11BF01+Z1 (25 mm diameter) amperometric, membrane-covered sensor Reliable disinfection for drinking and pool water, safety in food industry and utilities low-maintenance sensor, broad measuring range: 0 - 20 mg/l free chlorine long-time stable measurement, … [Read more...] about CCS51-AA11BF01+Z1
CPS16D-7BT21
Endress + Hauser CPS16D-7BT21 pH / ORP- combined electrode, Memosens functionality, Diaphragm PTFE, Reference Gel, Signal transmission digital, temperatur sensor integrated, ORP platinum electrode CPS16D-1009/0 Endress Hauser CPS 16D 7 Version: Basic version BT Application … [Read more...] about CPS16D-7BT21
CPS16D-7AT21+Z1
Endress + Hauser CPS16D-7AT21+Z1 pH / ORP- combined electrode, Memosens functionality, Diaphragm PTFE, Reference Gel, Signal transmission digital, temperatur sensor integrated, ORP platinum electrode CPS16D-10V6/0 Endress Hauser CPS 16D 7 Version: Basic version AT Application … [Read more...] about CPS16D-7AT21+Z1
CPS71D-7TC4V
Endress + Hauser CPS71D-7TC4V pH comb. electrode, Memosens functionality Signal transmission: Digital Diaphragm: Ceramic Reference system: Gel (non acrylamide), Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min … [Read more...] about CPS71D-7TC4V
OUSAF12-G0D0A
Endress + Hauser OUSAF12-G0D0A Color and NIR absorbance sensor, wavelength range 400-1500 nm Measuring range: up to 50 OD (depending on OPL) Light source: Low wattage incandescent lamp Endress Hauser OUSAF 12 G Wavelength: 1134 nm 0 Calibration/validation: Standard D Lamp: Gas … [Read more...] about OUSAF12-G0D0A
CPS41D-7AC4BC
Endress + Hauser CPS41D-7AC4BC pH-comb. electrode, Diaphragm: Ceramic Memosens functionality Reference: liquid Working limit: max. 10 bar Endress Hauser CPS 41D 7 Version: Basic version AC Application Range: 1-12pH; -15-80oC; 3 Diaphr. 4 Shaft length: 225 mm B Electrolyte … [Read more...] about CPS41D-7AC4BC
CCS51-AA11BF03+ND
Endress + Hauser CCS51-AA11BF03+ND (25 mm diameter) amperometric, membrane-covered sensor Reliable disinfection for drinking and pool water, safety in food industry and utilities low-maintenance sensor, broad measuring range: 0 - 20 mg/l free chlorine long-time stable measurement, … [Read more...] about CCS51-AA11BF03+ND