Endress + Hauser NMS80-AA2BA1A1A1AB1AC21AAA1AFAICR

Level/Interface/Density profile, Servo
Precision device
Application: liquids, liquified gases
Highly precise measurement for
custody transfer and inventory control
Hybrid tank measurement system
Tank correction algorithms.
Flexible fieldbuses, inputs and outputs
Complete tank sensor integration
:: Custody transfer certified
:: SIL2 / SIL3 according IEC61508
:: Level, interface, density profile
NMS80-5WC0/0
Endress Hauser NMS 80
AA Approval: Non-hazardous area
2 Terminal Type: Screw terminals
B Power Supply; Display: 85-264VAC; LCD + operation
A1 Primary Output: Modbus RS485
A1 Secondary I/O Analogue: Ex d/XP, 1x 4-20mA HART, 1x RTD input
A1 Secondary I/O Digital Ex d/XP: 2x relay / 2x module discrete
AB Housing: Transmitter + process Alu, coated
1 Process Pressure: 0…0.2bar/20kPa/2.9psi
A Electrical Connection: Thread M20, IP66/68 NEMA Type 4X/6P Encl.
C2 Measuring Range; Wire; Diameter: 22m; AlloyC276; 0.2mm
1AA Displacer Material; Type: 316L; 30mm cylindrical
A1 Process Sealing: HNBR -30…150oC/-22…302oF
AFA Process Connection: NPS 3” Cl.150 RF, Alu flange ASME B16.5
ICR Accuracy, Weight + Measure Approval: Standard version, w/o calibration certificate