Endress + Hauser FMB70-ABA1P12TRCAA
Deltapilot S FMB70
A Approval: Non-hazardous area
B Output; Operating: 4-20mA HART; inside + LCD
A Housing; Cover Sealing; Cable Entry: T14 Alu IP66/67 NEMA6P; EPDM; M20 gland, T14 = side cover
1P Sensor Range; Sensor Overload Limit: 10bar/1MPa/150psi/100mH2O/4000inH2O 40bar/4MPa/600psi/400mH2O/16000inH2O
1 Calibration; Unit: Sensor range; mbar/bar
2 Membrane Material; Seal: AlloyC276; welded
TR Process Connection: Varivent N tube DN40-162 PN40, 316L, 3A, EHEDG
C Fill Fluid: Synthetic oil (FDA)
A Additional Option 1: Not selected
A Additional Option 2: Not selected