Endress + Hauser FMD78-IA27DBEAF1C4
Differential pressure.
Diaphragm seal + capillary.
Application: level, hydrostatic.
Secondary process barrier.
:: High long term stability.
:: Enhanced mechanical integrity.
:: High static pressure +
overload safety.
:: Modular.
FMD78-77EU2/0
Endress Hauser FMD 78
I Approval: IECEx Ex ia IIC T6 Ga/Gb
A Output; Operating: 4-20mA HART; extern + LCD
2 Housing; Cover Sealing; Cable Entry: T14 316L IP66/67 NEMA6P; EPDM; G1/2 thread, T14 = side cover
7D Nominal Range; Cell Material; PN: 100mbar/10kPa/1.5psi; 316L; 160bar/ 16MPa/2400psi
B Calibration; Unit: **Customised; see additional spec.
E Membrane Material: 316L, TempC
AF Process Connection: NPS 2” Cl.150 RF, 316/316L flange ASME B16.5
1 Fill Fluid: 1,0 – 10,0 m capillary, silicone oil
C Additional Option 1: Certificate of conformity NACE MR0175, wetted metallic parts
4 Additional Option 2: Pressure test, internal procedure, test report