Endress + Hauser FMD72-CA24BAD1F1FGABCBCACJACJA1
Differential pressure electronical,
piezoresitive.
Membrane: metal, welded.
Level, volume- / mass measurement
in pressurized / vacuum systems.
:: Highest process availability,
reliability and safety by eliminating
traditional mechanical issues
of inferior dp measurements.
:: Lowest total cost of ownership due to
reduced installation time, maintenance
FMD72-1KVA4/0
Endress Hauser FMD 72
CA Approval: CSA C/US IS Cl.I Div.1 Gr.A-D, Ex ia zone 0,1,2
2 Output: 4-20mA HART
4 Display, Operation: LCD, operation internal
B Housing Transmitter: Stainless steel T14
A Housing Sensor Module: Aluminium
D Electrical Connection: Thread NPT1/2
1F Sensor Range Sensor 1 (HP): 400mbar/40kPa/6psi gauge, overload: 6bar/600kPa/90psi
1F Sensor Range Sensor 2 (LP): 400mbar/40kPa/6psi gauge, overload: 6bar/600kPa/90psi
G Reference Accuracy: Standard
A Calibration; Unit: Level range; %
BC Cable Length Sensor > Transmitter: 6ft; 1.82m
BC Cable Length Sensor > Sensor: 6ft; 1.82m
ACJ Process Connection Sensor 1 (HP): NPS 1” Cl.150 RF, 316/316L flange ASME
ACJ Process Connection Sensor 2 (LP): NPS 1” Cl.150 RF, 316/316L flange ASME
A Membrane Material: 316L
1 Fill Fluid: Silicone oil