Endress + Hauser PMP75-ABR1HC1TRAAA Cerabar S PMP75

Digital pressure transmitter Cerabar PMP75
A Approval: Non-hazardous area
B Output; Operating: 4-20mA HART; inside + LCD
R Housing; Cover Sealing; Cable Entry: T17 316L hygiene IP66/68 NEMA6P;EPDM;M20 gland, T17 = side cover
1H Sensor Range; Sensor Overload Limit: 1bar/100kPa/15psi gauge; 10bar/1MPa/150psi
C Calibration; Unit: **Works calib. certificate
5-point; see additional spec.
1 Membrane Material: 316L
TR Process Connection: Varivent N tube DN40-162 PN40, 316L, EHEDG, 3A
A Transmitter Mounting; Fill Fluid: Direct; silicone oil
A Additional Option 1: Not selected
A Additional Option 2: Not selected