Endress + Hauser PMC11-AA1U1KJWAJJ
Cost-effective pressure transducer with ceramic sensor for measurement in gases or liquids
Application: pressure/level
Accuracy +/-0.5%
Membrane: ceramic Ceraphire, oil free, vacuum proof
:: Longterm stable + overload resistant
PMC11-4FK3/101
Endress Hauser PMC 11
AA Approval: Non-hazardous area
1 Output: 4-20mA
U Electrical Connection: Valve plug ISO4400 M16, IP65 NEMA Type 4X Encl.
1K Sensor Range: 2bar/200kPa/30psi gauge, overload: 18bar/1.8MPa/270psi
J Calibration; Unit: Customized; see additional spec.
WAJ Process Connection: Thread ISO228 G1/4 (internal), 316L
J Seal: EPDM