Endress + Hauser FMR56-IBEAAABNUAE
Level, radar, contactless
Basic device
Application: solids
Integrated data memory
:: High availability
:: Reliable measuring:
in dusty atmosphere,
in abrasive medias
for changing temperatures
and independent from pulling forces
FMR56-91D9/0
Endress Hauser FMR 56
IB Approval: IEC Ex ia IIC T6 Ga/Gb
E Power Supply; Output: 2-wire; FOUNDATION Fieldbus, switch output
A Display, Operation: W/o, via communication
A Housing: GT19 dual compartment, plastic PBT
A Electrical Connection: Gland M20, IP66/68 NEMA4X/6P
BN Antenna: Horn 80mm/3”, PP cladded, -40…80oC/-40…176oF
UAE Process Connection: Mounting bracket, 304