Endress + Hauser FMR540-1E2CKJAC2AA
High precision level measurement, radar,
26GHz, contactless
Application: liquids
4-wire connection
Setup-/diagnostic software
included
Volume calculation / linearization
Free space application
High precision measurement
:: Independent of temperature/pressure
:: Independent of steam
:: Independent of gas layers
:: Pressure/gastight process separation
Endress Hauser FMR 540
1 Approval: ATEX II 1/2G EEx ia IIC T6
E Antenna; Seal: 100mm/4” horn, align device; FKM Viton GLT
2 Antenna Extension: 150mm/6”
CKJ Process Connection: DN200 PN16 B1, 316L flange EN1092-1 (DIN2527 C)
A Output; Operating: 4-20mA HART; 4-line display VU331, envelope curve display on site
C Housing: T12 Alu, coated IP65/68 NEMA Type 4X/6P Encl, separate conn compartment
2 Cable Entry: Gland M20
A Weight + Measure Approval: NMi (<1mm) Type approval
A Additional Option: Basic version