Endress + Hauser FMP50-8CAACCAAA1RDJ Level, radar, guided Basic device Application: liquids Integrated data memory Factory precalibrated :: High availability :: Reliable measuring for changing medias FMP50-133E2/0 Endress Hauser FMP 50 8C Approval: FM IS, Cl I, DIV 1, GP ABCD, … [Read more...] about FMP50-8CAACCAAA1RDJ
Endress + Hauser FMP50 Levelflex Guided radar level measurement in basic liquids
Endress + Hauser Levelflex FMP50 is the instrument for basic applications in liquids which do not place high demands on temperature and pressure ranges or chemical resistance.
Integrated data memory, Factory precalibrated, Reliable measuring for changing medias.
Endress + Hauser FMP50 Guided radar level measurement measuring principle:
Endress + Hauser FMP50 Guided radar level max. measurement distance:
Rod: 4 m (13 ft) Min DK>1.6
Rope: 12 m (40 ft) Min DK>1.6
Endress + Hauser FMP50 Guided radar level measurement application:
• Process connections: Thread or adapter flange
• Temperature: -20 to +80°C (-4 to +176°F)
• Pressure: -1 to +6bar (-14.5 to +87psi)
• Maximum measuring range: Rod 4m (13ft), rope 12m (39ft)
• Accuracy: ±2mm (0.08")
• International explosion protection certificates, overfill prevention WHG, SIL, 5-point linearity protocol
Endress + Hauser FMP50 Guided radar level measurement advantages:
• HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
• Highest reliability due to new Multi-Echo Tracking evaluation
• Hardware and software developed according to IEC 61508 up to SIL3
• Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
• Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
• World's easiest proof test for SIL and WHG saves time and costs
Endress + Hauser FMP50 Guided radar level measurement Ambient temperature:
FMP50-NHAACBAAA1RDJ
Endress + Hauser FMP50-NHAACBAAA1RDJ Level, radar, guided Basic device Application: liquids Integrated data memory Factory precalibrated :: High availability :: Reliable measuring for changing medias FMP50-13338/0 Endress Hauser FMP 50 NH Approval: NEPSI Ex ic IIC T6 Gc … [Read more...] about FMP50-NHAACBAAA1RDJ
FMP50-FAAAAAAAA1GDJ
Endress + Hauser FMP50-FAAAAAAAA1GDJ Level, radar, guided Basic device Application: liquids Integrated data memory Factory precalibrated :: High availability :: Reliable measuring for changing medias FMP50-131E1/0 Endress Hauser FMP 50 FA Approval: FM IS ClI Div1 GrA-D … [Read more...] about FMP50-FAAAAAAAA1GDJ
FMP50-BBAAAAAAA1GDJ
Endress + Hauser FMP50-BBAAAAAAA1GDJ Level, radar, guided Basic device Application: liquids Integrated data memory Factory precalibrated :: High availability :: Reliable measuring for changing medias FMP50-9V62/0 Endress Hauser FMP 50 BB Approval: ATEX II 1/2G Ex ia IIC T6 … [Read more...] about FMP50-BBAAAAAAA1GDJ
FMP50-GAAAAAAAA1GDJ
Endress + Hauser FMP50-GAAAAAAAA1GDJ Level, radar, guided Basic device Application: liquids Integrated data memory Factory precalibrated :: High availability :: Reliable measuring for changing medias FMP50-131H7/0 Endress Hauser FMP 50 GA Approval: EAC Ex ia IIC T6 Ga A Power … [Read more...] about FMP50-GAAAAAAAA1GDJ
FMP50-CBAAAAAAA1GDJ
Endress + Hauser FMP50-CBAAAAAAA1GDJ Level, radar, guided Basic device Application: liquids Integrated data memory Factory precalibrated :: High availability :: Reliable measuring for changing medias FMP50-131A2/0 Endress Hauser FMP 50 CB Approval: CSA C/US IS ClI Div1 GrA-D … [Read more...] about FMP50-CBAAAAAAA1GDJ
FMP50-BLAACBAAA1GDJ
Endress + Hauser FMP50-BLAACBAAA1GDJ Level, radar, guided Basic device Application: liquids Integrated data memory Factory precalibrated :: High availability :: Reliable measuring for changing medias FMP50-131M3/0 Endress Hauser FMP 50 BL Approval: ***ATEX II 1/3G Ex nA[ia] IIC … [Read more...] about FMP50-BLAACBAAA1GDJ
FMP50-B3AACBAAA1GDJ
Endress + Hauser FMP50-B3AACBAAA1GDJ Level, radar, guided Basic device Application: liquids Integrated data memory Factory precalibrated :: High availability :: Reliable measuring for changing medias FMP50-131P9/0 Endress Hauser FMP 50 B3 Approval: ATEX II 1/2G Ex d[ia] IIC T6 … [Read more...] about FMP50-B3AACBAAA1GDJ
FMP50-NBAACBAAA1GDJ
Endress + Hauser FMP50-NBAACBAAA1GDJ Level, radar, guided Basic device Application: liquids Integrated data memory Factory precalibrated :: High availability :: Reliable measuring for changing medias FMP50-133H8/0 Endress Hauser FMP 50 NB Approval: NEPSI Ex ia IIC T6 Ga/Gb … [Read more...] about FMP50-NBAACBAAA1GDJ
FMP50-8BAACCAAA1GDJ
Endress + Hauser FMP50-8BAACCAAA1GDJ Level, radar, guided Basic device Application: liquids Integrated data memory Factory precalibrated :: High availability :: Reliable measuring for changing medias FMP50-133K0/0 Endress Hauser FMP 50 8B Approval: FM IS, Cl I, DIV 1, GP ABCD, … [Read more...] about FMP50-8BAACCAAA1GDJ
FMP50-MAAACBAAA1RDJ
Endress + Hauser FMP50-MAAACBAAA1RDJ Level, radar, guided Basic device Application: liquids Integrated data memory Factory precalibrated :: High availability :: Reliable measuring for changing medias FMP50-132X2/0 Endress Hauser FMP 50 MA Approval: INMETRO Ex ia IIC T6 Ga … [Read more...] about FMP50-MAAACBAAA1RDJ
FMP50-8CAACDAAA1GDJ
Endress + Hauser FMP50-8CAACDAAA1GDJ Level, radar, guided Basic device Application: liquids Integrated data memory Factory precalibrated :: High availability :: Reliable measuring for changing medias FMP50-133F3/0 Endress Hauser FMP 50 8C Approval: FM IS, Cl I, DIV 1, GP ABCD, … [Read more...] about FMP50-8CAACDAAA1GDJ
FMP50-IHAACBAAA1RDJ
Endress + Hauser FMP50-IHAACBAAA1RDJ Level, radar, guided Basic device Application: liquids Integrated data memory Factory precalibrated :: High availability :: Reliable measuring for changing medias FMP50-132W5/0 Endress Hauser FMP 50 IH Approval: IEC Ex ic IIC T6 Gc A Power … [Read more...] about FMP50-IHAACBAAA1RDJ