Endress + Hauser FTL71-BAC2BB4G5AL
Product being phased out – Limited
availability”.
Point level switch, vibronic.
Application: liquids + high
process temperature.
:: Liquid independent.
Short fork; extension tube.
:: Suitable on narrow mount. condition.
Integrated gastight feedthrough.
Highest safety under high pressure
FTL71-2P319/0
Endress Hauser FTL 71
B Approval: ATEX II 3G Ex nC IIC T6, WHG, ATEX II 3D Ex tc IIIC T85oC, NEPSI II 3G Ex nC IIC T6
AC2 Process Connection: NPS 1-1/2” Cl.150 RF, 316/316L flange ASME B16.5
BB Probe Length: 148-3000 mm L, Ra<3.2um/126uin, 316L, Fork: 318L
4 Electronics; Output: **FEL54;SILrelay DPDT 19-253VAC/19-55VDC
G5 Housing; Cable Entry: **F17 IP66/67 Alu; M20 gland
A Additional Option: Basic version
L Application: 230oC/450oF, gas-tight feed through