Endress + Hauser FTL51C-4BELBL5G4DC
Product being phased out – Limited
availability”.
Point level/density,
Vibronic.
Coated, extension tube.
Application: liquids.
Point level:
:: Millimeter precision switch point.
:: Application safety:
independent of liquid attribute,
independent of build up.
Density:
Continuous measurement.
:: Measure directly in the tank / pipe.
Endress Hauser FTL 51C
4 Approval: ATEX II 1/2G Ex ia IIC T6, WHG, XA note safety instruction (XA) (electrostatic charging)!
BEL Process Connection: DN50 PN6, PFA(Edlon)>316L flange EN1092-1
BL Probe Length; Type: ….. mm; PFA (Edlon)
5 Electronics; Output: FEL55; SIL 8/16mA, 11-36VDC
G4 Housing; Cable Entry: **F16 IP66/67 Polyester; M20 gland
D Additional Option 1: Product documentation on paper, EN10204-3.1 material (316L pressurized) inspection certificate
C Additional Option 2: 2nd line of defence > (press.tight feed through)