Endress + Hauser FTL50-1BB2QA5F7D

Product being phased out – Limited
availability”.
Point level/density, vibronic.
Application: liquids.
Point level:
:: Millimeter precision switch point.
:: Application safety:
independent of liquid attribute,
independent of build up.
Density:
Continuous measurement.
:: Measure directly in the tank / pipe
FTL50-234P0/0
Endress Hauser FTL 50
1 Approval: INMETRO Ex ia IIC T6 Ga/Gb
BB2 Process Connection: DN32 PN25/40 A, 316L flange EN1092-1
QA Probe Length; Type: Compact; press.tight feed through
5 Electronics; Output: FEL55; SIL 8/16mA, 11-36VDC
F7 Housing; Cable Entry: **T13 IP66/68 Alu, coated; G1/2 thread, separate conn. compartment
D Additional Option: EN10204-3.1 AD2000 material wetted parts, excepting castings inspection certificate