Endress + Hauser Promag 10W50-HT0A1AA0C4AA
Promag 10W50, DN50 2″
Endress + Hauser Electromagnetic flowmeter
Assign line 1 Volume flow
Assign line 2 Totalizer 1
Assign current output Volume flow
Failsafe mode current/pulse output Min. value
Assign pulse output Volume flow
Output signal Passive – negative
Current span 4-20 mA HART NAMUR
Pulse width 100,000 ms
Value 20 mA 300,000 dm3/min
Time constant 1,000 s
Pulse value (per pulse) 2,50000 dm3
Assign totalizer 1 Volume flow
Unit totalizer 1 dm3
H Liner: Hard rubber
T Process Connection: 10K, carbon steel, flange JIS B2220
0 Electrodes: 1.4435/316L
A Calibration: 0.5%
1 Additional Test: w/o
A Approval: Non-hazardous area
A Housing: Compact Alu, IP67 NEMA4X
0 Cable, Remote Version: Not used
C Cable Entry: Thread G 1/2
4 Power Supply; Display: 85-250VAC; 2-line, push buttons
A Adjustment; Software Feature: Factory setup; basic version
A Output: 4-20mA HART + pulse passive