Endress + Hauser COS61D Digital oxygen sensor Oxymax for water, wastewater and utilities

Endress + Hauser COS61D digital oxygen sensor E+H

Endress + Hauser COS61D Oxymax is a high-performance, digital oxygen sensor that offers fast, accurate and drift-free measurement. It supports your process with low maintenance, high availability and easy handling. Calibration data saved in sensor. High degree of EMC protection.

Endress + Hauser COS61D digital oxygen sensor measured value

  • Dissolved oxygen [mg/l, µg/l, ppm, ppb or %SAT or hPa]

Endress + Hauser COS61D digital oxygen sensor measuring range

Measuring ranges apply for 25 ˚C (77 ˚F) and 1013 hPa (15 psi)
With Liquiline CM44x, CM44xR, CM44P or with Liquisys COM2x3-W:
• 0 to 20 mg/l
• 0 to 400 hPa
• 0 to 200 % SAT

Endress + Hauser COS61D digital oxygen sensor application

Oxymax COS61D measures the dissolved oxygen concentration in:
Wastewater treatment plants:
- O2 control in the aeration basin
- Process water treatment and monitoring
Water works:
- Status monitoring of drinking water (oxygen enrichment, corrosion protection, etc.)
- Water quality monitoring in rivers, lakes or seas
Utilities of all industries:
- O2 control in the biological treatment
- Process water treatment and monitoring
Fish farming:
- O2 control for optimum growth conditions

Endress + Hauser COS61D digital oxygen sensor advantages are

• Minimum maintenance, maximum availability
• Fast, drift-free measurement for precise aeration control and process monitoring
• Long-term stability for increased process safety
• Outstanding performance in all aeration processes (SBR, Anamox, etc.)
• Chemical-free: no electrolyte handling

Endress + Hauser COS61D digital oxygen sensor process temperature

–5 to +60 ˚C (20 to 140 ˚F)

Endress + Hauser COS61D digital oxygen sensor process pressure

Ambient pressure ... 10 bar (... 145 psi) abs.

COS61D-GRA1A2

© E+H Digital oxygen sensor COS61D-GRA1A2

Endress + Hauser COS61D-GRA1A2 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration Endress Hauser COS 61D GR Approval: non-hazardous area + EAC marking … [Read more...] about COS61D-GRA1A2

COS61D-GRA1B3

© E+H Digital oxygen sensor COS61D-GRA1B3

Endress + Hauser COS61D-GRA1B3 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration Endress Hauser COS 61D GR Approval: non-hazardous area + EAC marking … [Read more...] about COS61D-GRA1B3

COS61D-GRA1A4

© E+H Digital oxygen sensor COS61D-GRA1A4

Endress + Hauser COS61D-GRA1A4 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration COS61D-1NQ7/0 Endress Hauser COS 61D GR Approval: non-hazardous area + EAC marking … [Read more...] about COS61D-GRA1A4

COS61D-AAA1B3

© E+H Digital oxygen sensor COS61D-AAA1B3

Endress + Hauser COS61D-AAA1B3 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration Endress Hauser COS 61D AA Approval: Non-hazardous area A1 Application/Measuring … [Read more...] about COS61D-AAA1B3

COS61D-AAA1A4

© E+H Sensor digital para la medición de oxígeno COS61D-AAA1A4

Endress + Hauser COS61D-AAA1A4 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration COS61D-1009/0 Endress Hauser COS 61D AA Approval: Non-hazardous area … [Read more...] about COS61D-AAA1A4

COS61D-AAA1A3

© E+H Digital oxygen sensor COS61D-AAA1A3

Endress + Hauser COS61D-AAA1A3 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration Endress Hauser COS 61D AA Approval: Non-hazardous area A1 Application/Measuring … [Read more...] about COS61D-AAA1A3

COS61D-AAA1B4

© E+H Digital oxygen sensor COS61D-AAA1B4

Endress + Hauser COS61D-AAA1B4 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration COS61D-1040/0 Endress Hauser COS 61D AA Approval: Non-hazardous area … [Read more...] about COS61D-AAA1B4

COS61D-AAA1A8

© E+H Digital oxygen sensor COS61D-AAA1B2

Endress + Hauser COS61D-AAA1A8 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration COS61D-1AX1/0 Endress Hauser COS 61D AA Approval: Non-hazardous area … [Read more...] about COS61D-AAA1A8

COS61D-GRA1A7

© E+H Digital oxygen sensor COS61D-GRA1A7

Endress + Hauser COS61D-GRA1A7 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration COS61D-2112/0 E+H COS61D GR Approval: non-hazardous area + EAC marking … [Read more...] about COS61D-GRA1A7

COS61D-GRA1B8

© E+H Digital oxygen sensor COS61D-GRA1B8

Endress + Hauser COS61D-GRA1B8 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration COS61D-25V5/0 Endress Hauser COS 61D GR Approval: non-hazardous area + EAC marking … [Read more...] about COS61D-GRA1B8

COS61D-GRA1A8

© E+H Digital oxygen sensor COS61D-GRA1A8

Endress + Hauser COS61D-GRA1A8 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration COS61D-GRA1A8 Endress Hauser COS 61D GR Approval: non-hazardous area + EAC marking … [Read more...] about COS61D-GRA1A8

COS61D-AAA1A2

© E+H Digital oxygen sensor COS61D-AAA1A2

Endress + Hauser COS61D-AAA1A2 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration Endress Hauser COS 61D AA Approval: Non-hazardous area A1 Application/Measuring … [Read more...] about COS61D-AAA1A2

COS61D-AAA1A7

© E+H Digital oxygen sensor COS61D-AAA1A7

Endress + Hauser COS61D-AAA1A7 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration COS61D-18L7/0 Endress Hauser COS 61D AA Approval: Non-hazardous area … [Read more...] about COS61D-AAA1A7

COS61D-GRA1A3

© E+H Digital oxygen sensor COS61D-GRA1A3

Endress + Hauser COS61D-GRA1A3 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration Endress Hauser COS 61D GR Approval: non-hazardous area + EAC marking … [Read more...] about COS61D-GRA1A3

COS61D-GRA1B2

© E+H Digital oxygen sensor COS61D-GRA1B2

Endress + Hauser COS61D-GRA1B2 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration Endress Hauser COS 61D GR Approval: non-hazardous area + EAC marking … [Read more...] about COS61D-GRA1B2

COS61D-AAA1B7

© E+H Digital oxygen sensor COS61D-AAA1B7

Endress + Hauser COS61D-AAA1B7 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration COS61D-23Q0/0 Endress Hauser COS 61D AA Approval: Non-hazardous area … [Read more...] about COS61D-AAA1B7

COS61D-GRA1B7

© E+H Digital oxygen sensor COS61D-GRA1B7

Endress + Hauser COS61D-GRA1B7 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration COS61D-25R3/0 Endress Hauser COS 61D GR Approval: non-hazardous area + EAC marking … [Read more...] about COS61D-GRA1B7

COS61D-GRA1B4

© E+H Digital oxygen sensor COS61D-GRA1B4

Endress + Hauser COS61D-GRA1B4 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration COS61D-1Q67/0 Endress Hauser COS 61D GR Approval: non-hazardous area + EAC marking … [Read more...] about COS61D-GRA1B4

COS61D-AAA1B2

© E+H Digital oxygen sensor COS61D-AAA1B2

Endress + Hauser COS61D-AAA1B2 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration Endress Hauser COS 61D AA Approval: Non-hazardous area A1 Application/Measuring … [Read more...] about COS61D-AAA1B2

COS61D-AAA1B8

© E+H Digital oxygen sensor COS61D-AAA1B8

Endress + Hauser COS61D-AAA1B8 Dissolved oxygen sensor; optical Application: Water, Wastewater Digital sensor, Memosens protocol Sensor heat: G1, NPT3/4 Automatic sensorcheck Factory calibration COS61D-25U0/0 Endress Hauser COS 61D AA Approval: Non-hazardous area … [Read more...] about COS61D-AAA1B8

Primary Sidebar

Contact us:





    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • FMR54-BBBAAAAAA8CHJ
    • PMC11-AA1V1KBWTJA
    • PMC11-AA1V1KBWWJA
    • FMR54-BHBAAAAAA8CHJ
    • FMR56-IBCAAABRXR0
    • PMC11-AA1V1HBWTJA
    • PMC11-AA1V1FBWBJJ
    • RH33-CP1A+AAB1
    • FMR54-BABCAAAAA8CHJ
    • FMR56-IHBAAABRUAE
    • CA76NA-AAAC1E41+F5
    • PMC11-AA1V1HJWWJJ
    • CA72TOC-B2A2E2
    • FMR54-BHBCAAAAA8CHJ
    • FMR56-BAAAAABRUAE
    • FMD71-BC24AAD1C1CGABCBCACJACJG
    • PMC11-AA1V1HJWTJJ
    • CA72TOC-D3A2E2
    • FMR54-AAAAAAAAA8CHJ
    • Spare hoses for hose pump Bredel 50

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2022 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.