Endress + Hauser COS51D Digital oxygen sensor Oxymax for water, wastewater and utilities

Endress + Hauser COS51D digital oxygen sensor E+H

Endress + Hauser COS51D Oxymax is a reliable and highly accurate oxygen sensor for all kinds of water & wastewater applications (including hazardous areas). Digital signal transmission. Storage of the calibration datas in the sensor.

Endress + Hauser COS51D digital oxygen sensor measured value

  • Dissolved oxygen [mg/l, μg/l, ppm, ppb, % SAT or hPa]

Endress + Hauser COS51D digital oxygen sensor measuring range

0.01 to 100 mg/l
0.00 to 1000 % SAT
0 to 2000 hPa

Endress + Hauser COS51D digital oxygen sensor application

Oxymax COS51D measures the dissolved oxygen concentration in:
Wastewater treatment plants:
- O2 control in the aeration basin
- Process water treatment and monitoring
Water works:
- Status monitoring of drinking water (oxygen enrichment, corrosion protection, etc.)
- Water quality monitoring in rivers, lakes or seas
Utilities of all industries:
- O2 control in the biological treatment
- Process water treatment and monitoring
The sensor is suitable for hazardous area use (ATEX, FM, CSA).

Endress + Hauser COS51D digital oxygen sensor advantages are

• Maximum measurement accuracy
• Logging of sensor load data for easy traceability
• Intelligent, self-monitoring sensor
• Minimum calibration effort thanks to simple air calibration
• Long maintenance intervals
• Approved for hazardous area use

Endress + Hauser COS51D digital oxygen sensor process temperature

–5 to 50 ˚C (20 to 120 ˚F)

Endress + Hauser COS51D digital oxygen sensor process pressure

Ambient pressure ... 10 bar (... 145 psi) abs.

COS51D-OS910

© E+H Digital oxygen sensor COS51D-OS910

Endress + Hauser COS51D-OS910 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress Hauser COS 51D O Approval: FM / CSA IS/NI CL I DIV1&2 GP A-D S Head type: thread NPT 3/4; G1; … [Read more...] about COS51D-OS910

COS51D-GS910

© E+H Digital oxygen sensor COS51D-GS910

Endress + Hauser COS51D-GS910 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress Hauser COS 51D G Approval: ATEX II 1G / IECEx Ex ia IIC T6 Ga S Head type: thread NPT 3/4; G1; … [Read more...] about COS51D-GS910

COS51D-CS910

© E+H Digital oxygen sensor COS51D-CS910

Endress + Hauser COS51D-CS910 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress Hauser COS 51D C Approval: non-hazardous area + EAC marking S Head type: thread NPT 3/4; G1; … [Read more...] about COS51D-CS910

COS51D-OS800

© E+H Digital oxygen sensor COS51D-OS800

Endress + Hauser COS51D-OS800 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress Hauser COS 51D O Approval: FM / CSA IS/NI CL I DIV1&2 GP A-D S Head type: thread NPT 3/4; G1; … [Read more...] about COS51D-OS800

COS51D-AS800

© E+H Digital oxygen sensor COS51D-AS800

Endress + Hauser COS51D-AS800 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress Hauser COS 51D A Approval: non-hazardous area S Head type: thread NPT 3/4; G1; memosens connector … [Read more...] about COS51D-AS800

COS51D-GS800

© E+H Digital oxygen sensor COS51D-GS800

Endress + Hauser COS51D-GS800 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress Hauser COS 51D G Approval: ATEX II 1G / IECEx Ex ia IIC T6 Ga S Head type: thread NPT 3/4; G1; … [Read more...] about COS51D-GS800

COS51D-AS910

© E+H Digital oxygen sensor COS51D-AS910

Endress + Hauser COS51D-AS910 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress + Hauser COS 51D A Approval: non-hazardous area S Head type: thread NPT 3/4; G1; memosens … [Read more...] about COS51D-AS910

COS51D-KS800

© E+H Digital oxygen sensor COS51D-KS800

Endress + Hauser COS51D-KS800 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress Hauser COS 51D K Approval: EAC Ex, 0Ex ia IIC T6 Ga X S Head type: thread NPT 3/4; G1; memosens … [Read more...] about COS51D-KS800

COS51D-CS800

© E+H Digital oxygen sensor COS51D-CS800

Endress + Hauser COS51D-CS800 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress Hauser COS 51D C Approval: non-hazardous area + EAC marking S Head type: thread NPT 3/4; G1; … [Read more...] about COS51D-CS800

COS51D-KS910

© E+H Digital oxygen sensor COS51D-KS910

Endress + Hauser COS51D-KS910 Dissolved oxygen Sensor, amperometrical Application: Water, Wastewater Memosens-technology Measuring range: 0.0-100 mg/l Automatic sensorcheck Endress Hauser COS 51D K Approval: EAC Ex, 0Ex ia IIC T6 Ga X S Head type: thread NPT 3/4; G1; memosens … [Read more...] about COS51D-KS910

Primary Sidebar

Contact us:





    What is 1 + 4

    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • TM131-U4AAAFA2AA3AAAB0AA1AA1
    • TM131-URAAAFA2AA3AAAB0AA1AA1
    • TM131-U5AAAFA2AA3AAAB0AA1AA1
    • TM131-8FAAAFA2AA3AAAB0AA1AA1
    • TM131-URAAAFA2AA2AAAB0AA1AA1
    • TM131-U4AAAFA2AA2AAAB0AA1AA1
    • TM131-8FAAAFA1AA3AAAB0AA1AA1
    • TM131-AAAAAFA1AA4AAAB0AA1AA1
    • TM131-G4AAAFA1AA8AAAB0AA1AA1
    • TM131-84AAAFA2AA2AAAB0AA1AA1
    • TM131-CGAAAFA2AA3AAAB0AA1AA1
    • TM131-GFAAAFA2AA3AAAB0AA1AA1
    • TM121-GRHBB1A6BC1A3A1
    • TM131-GJAAAFA1AA5AAAB0AA1AA1
    • TM131-MAAAAFA1AA8AAAB0AA1AA1
    • TM121-AAACB1A4BA1A3A1
    • TM111-MAAABA1BBB0AA1AA1
    • TM111-U5ABAA1BBB0AA1AA1
    • TM121-URA4BA1A3A1
    • TM131-NFAAAFA1AA4AAAB0AA1AA1

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2025 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.