Endress + Hauser CPS76D-7BU2G pH/combined electrode, Memosens functionality, Diaphragm ceramic, Reference Gel (non acrylamide), Signal transmission digital, Temperature sensor integrated, ORP platinum electrode CPS76D-10J0/0 Endress Hauser CPS 76D 7 Version: Basic version … [Read more...] about CPS76D-7BU2G
Endress + Hauser CPS76D Digital combined pH/ORP sensor for food and life sciences industries
Digital combined pH/ORP sensor CPS76D is the hygienic and sterile expert for simultaneous pH and ORP measurement offering a brilliant process control and increased quality. All shaft lengths with temperature sensor - advanced gel technology - digital electrode with Memosens technology.
CPS76D measured value
- pH
- ORP
- rH
- temperature
CPS76D application
- Fermenters
- Biotechnology
- Life sciences
- Food industry
• Process technology and monitoring of processes with:
- Quickly changing pH values
- High proportion of electrode poisons such as H2S
With ATEX, FM, and CSA approval for application in hazardous areas.
CPS76D advantages
• Additional platinum electrode enables constant monitoring of reference impedance and thus sensor quality
• Robust and resistant to poisoning thanks to new acrylamide-free bridge electrolyte and reference with ion trap
• Suitable for CIP/SIP and autoclaving
• Maximum process safety through non-contact inductive signal transmission
• Enables predictive maintenance due to storage of sensor and process-specific data
• Reduced operating costs thanks to minimized process downtime and extended sensor lifetime
CPS76D measuring range
ORP: -1500 to 1500 mV
rH: 0...42
Temperature:
BB version - 0 to 140 °C (32 to 280 °F)
BU version - 0 to 135 °C 1) (32 to 280 °F)
Version BP (pressurized) 0 to 140 °C 2) (32 to 280 °F)
CPS76D process temperature
BU, BP version: 0 to 100 °C (32 to 212 °F),
can be sterilized up to 140 °C (280 °F) for 30 minutes, at
least 30 sterilization cycles
CPS76D process pressure
BU version: 1 to 11 bar (15 to 160 psi)
BP version: 1 to 7 bar (15 to 102 psi)
CPS76D storage temperature
CPS76D-7BP6G
Endress + Hauser CPS76D-7BP6G pH/combined electrode, Memosens functionality, Diaphragm ceramic, Reference Gel (non acrylamide), Signal transmission digital, Temperature sensor integrated, ORP platinum electrode CPS76D-10M7/0 Endress Hauser CPS 76D 7 Version: Basic version … [Read more...] about CPS76D-7BP6G
CPS76D-7BP2G
Endress + Hauser CPS76D-7BP2G pH/combined electrode, Memosens functionality, Diaphragm ceramic, Reference Gel (non acrylamide), Signal transmission digital, Temperature sensor integrated, ORP platinum electrode CPS76D-10H0/0 Endress Hauser CPS 76D 7 Version: Basic version … [Read more...] about CPS76D-7BP2G
CPS76D-7BP4C
Endress + Hauser CPS76D-7BP4C pH/combined electrode, Memosens functionality, Diaphragm ceramic, Reference Gel (non acrylamide), Signal transmission digital, Temperature sensor integrated, ORP platinum electrode CPS76D-1369/0 Endress Hauser CPS 76D 7 Version: Basic version … [Read more...] about CPS76D-7BP4C
CPS76D-7BB2K
Endress + Hauser CPS76D-7BB2K pH/combined electrode, Memosens functionality, Diaphragm ceramic, Reference Gel (non acrylamide), Signal transmission digital, Temperature sensor integrated, ORP platinum electrode CPS76D-11P7/0 Endress Hauser CPS 76D 7 Version: Basic version … [Read more...] about CPS76D-7BB2K
CPS76D-7BU2C
Endress + Hauser CPS76D-7BU2C pH/combined electrode, Memosens functionality, Diaphragm ceramic, Reference Gel (non acrylamide), Signal transmission digital, Temperature sensor integrated, ORP platinum electrode CPS76D-1223/0 Endress Hauser CPS 76D 7 Version: Basic version … [Read more...] about CPS76D-7BU2C
CPS76D-7BB4G
Endress + Hauser CPS76D-7BB4G pH/combined electrode, Memosens functionality, Diaphragm ceramic, Reference Gel (non acrylamide), Signal transmission digital, Temperature sensor integrated, ORP platinum electrode CPS76D-11K0/0 Endress Hauser CPS 76D 7 Version: Basic version … [Read more...] about CPS76D-7BB4G
CPS76D-7BB2C
Endress + Hauser CPS76D-7BB2C pH/combined electrode, Memosens functionality, Diaphragm ceramic, Reference Gel (non acrylamide), Signal transmission digital, Temperature sensor integrated, ORP platinum electrode CPS76D-11Q2/0 Endress Hauser CPS 76D 7 Version: Basic version … [Read more...] about CPS76D-7BB2C
CPS76D-7BB5G
Endress + Hauser CPS76D-7BB5G pH/combined electrode, Memosens functionality, Diaphragm ceramic, Reference Gel (non acrylamide), Signal transmission digital, Temperature sensor integrated, ORP platinum electrode CPS76D-11U4/0 Endress Hauser CPS 76D 7 Version: Basic version … [Read more...] about CPS76D-7BB5G
CPS76D-7BP2C
Endress + Hauser CPS76D-7BP2C pH/combined electrode, Memosens functionality, Diaphragm ceramic, Reference Gel (non acrylamide), Signal transmission digital, Temperature sensor integrated, ORP platinum electrode CPS76D-11V0/0 Endress + Hauser CPS76D-7BP2C 7 Version: Basic … [Read more...] about CPS76D-7BP2C
CPS76D-7BU4G
Endress + Hauser CPS76D-7BU4G pH/combined electrode, Memosens functionality, Diaphragm ceramic, Reference Gel (non acrylamide), Signal transmission digital, Temperature sensor integrated, ORP platinum electrode CPS76D-10W1/0 Endress Hauser CPS 76D 7 Version: Basic version … [Read more...] about CPS76D-7BU4G
CPS76D-7BB6G
Endress + Hauser CPS76D-7BB6G pH/combined electrode, Memosens functionality, Diaphragm ceramic, Reference Gel (non acrylamide), Signal transmission digital, Temperature sensor integrated, ORP platinum electrode CPS76D-10N2/0 Endress Hauser CPS 76D 7 Version: Basic version … [Read more...] about CPS76D-7BB6G
CPS76D-7BU6G
Endress + Hauser CPS76D-7BU6G pH/combined electrode, Memosens functionality, Diaphragm ceramic, Reference Gel (non acrylamide), Signal transmission digital, Temperature sensor integrated, ORP platinum electrode CPS76D-1118/0 Endress Hauser CPS 76D 7 Version: Basic version … [Read more...] about CPS76D-7BU6G