Endress + Hauser CPS72-0PT2ESC ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT2ESC
Endress + Hauser CPS72 analog ORP sensor / glass electrode for food and life sciences industries
CPS72 sensor is the analog specialist for ORP measurement in sterile and hygienic applications. Its state-of-the-art gel is poison resistant and guarantees stable measurement even in flowing media or low conductivity.
Gel-compact-electrode with ceramic diaphragm - Platinum-cap - CIP/SIP and autoclavable - high accuracy.
CPS72 measured value
- ORP
- Temperature
CPS72 application
- Fermenters
- Biotechnology
- Life sciences
- Food industry
• Process technology and monitoring of processes with:
- Quickly changing pH values
- High proportion of electrode poisons such as H2S
With ATEX, FM, and CSA approval for application in hazardous areas
CPS72 advantages
• Sensor resists strong acids and bases and high organic loads
• Certified biocompatibility, no cytotoxicity
• Free from animal-based materials and from acrylamide
CPS72 measuring range
Temperature: -15 to 140 ˚C (5 to 284 ˚F)
0 to 135 ˚C (32 to 275 ˚F) for sensors with Ex approval and analog sensors
sensors
CPS72 process temperature
-15 to 135 ˚C (5 to 275 ˚F) for sensors with Ex approval and analog sensors
CPS72 process pressure
CPS72 storage temperature
CPS72-0PT4GSA
Endress + Hauser CPS72-0PT4GSA ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT4GSA
CPS72-0PT2ESK
Endress + Hauser CPS72-0PT2ESK ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT2ESK
CPS72-0PT4ESK
Endress + Hauser CPS72-0PT4ESK ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT4ESK
CPS72-0PT4ESC
Endress + Hauser CPS72-0PT4ESC ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT4ESC
CPS72-0PT5ESK
Endress + Hauser CPS72-0PT5ESK ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT5ESK
CPS72-0PT2GSA
Endress + Hauser CPS72-0PT2GSA ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT2GSA
CPS72-0PT5ESC
Endress + Hauser CPS72-0PT5ESC ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT5ESC
CPS72-0PT5ESA
Endress + Hauser CPS72-0PT5ESA ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT5ESA
CPS72-0PT4ESA
Endress + Hauser CPS72-0PT4ESA ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT4ESA
CPS72-0PT2ESA
Endress + Hauser CPS72-0PT2ESA ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT2ESA
CPS72-0PT5GSA
Endress + Hauser CPS72-0PT5GSA ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT5GSA