• Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Bromberg, Staudt & Co. GmbH

  • Home
  • About us
  • Our services
  • Industries
  • Brands
    • Endress+Hauser
    • EAGLE Burgmann Mechanical Shaft Seals
  • Contacts
  • EnglishEnglish
    • EspañolEspañol
    • TagalogTagalog
    • 한국어한국어
    • 中文 (中国)中文 (中国)
    • DeutschDeutsch
Home / Endress+Hauser / E+H Analytics / Sensors/Electrodes / CPS72

Endress + Hauser CPS72 analog ORP sensor / glass electrode for food and life sciences industries

ENDRESS + HAUSER analog ORP sensor CPS72

CPS72 sensor is the analog specialist for ORP measurement in sterile and hygienic applications. Its state-of-the-art gel is poison resistant and guarantees stable measurement even in flowing media or low conductivity.
Gel-compact-electrode with ceramic diaphragm - Platinum-cap - CIP/SIP and autoclavable - high accuracy.

CPS72 measured value

  • ORP
  • Temperature

CPS72 application

• Hygienic and sterile applications:
- Fermenters
- Biotechnology
- Life sciences
- Food industry
• Process technology and monitoring of processes with:
- Quickly changing pH values
- High proportion of electrode poisons such as H2S
With ATEX, FM, and CSA approval for application in hazardous areas

CPS72 advantages

• Suitable for CIP/SIP and autoclaving maintaining high accuracy
• Sensor resists strong acids and bases and high organic loads
• Certified biocompatibility, no cytotoxicity
• Free from animal-based materials and from acrylamide

CPS72 measuring range

ORP: -1500 mV - +1500 mV
Temperature: -15 to 140 ˚C (5 to 284 ˚F)
0 to 135 ˚C (32 to 275 ˚F) for sensors with Ex approval and analog sensors
sensors

CPS72 process temperature

-15 to 140 ˚C (5 to 284 ˚F)
-15 to 135 ˚C (5 to 275 ˚F) for sensors with Ex approval and analog sensors

CPS72 process pressure

0.8 to 11 bar (12 to 160 psi)

CPS72 storage temperature

0 to 50 °C (32 to 120 °F)

CPS72-0PT2ESC

© E+H ORP-comb.-electrode CPS72-0PT2ESC

Endress + Hauser CPS72-0PT2ESC ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT2ESC

CPS72-0PT4GSA

© E+H ORP-comb.-electrode CPS72-0PT4GSA

Endress + Hauser CPS72-0PT4GSA ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT4GSA

CPS72-0PT2ESK

© E+H ORP-comb.-electrode CPS72-0PT2ESK

Endress + Hauser CPS72-0PT2ESK ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT2ESK

CPS72-0PT4ESK

© E+H ORP-comb.-electrode CPS72-0PT4ESK

Endress + Hauser CPS72-0PT4ESK ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT4ESK

CPS72-0PT4ESC

© E+H ORP-comb.-electrode CPS72-0PT4ESC

Endress + Hauser CPS72-0PT4ESC ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT4ESC

CPS72-0PT5ESK

© E+H ORP-comb.-electrode CPS72-0PT5ESK

Endress + Hauser CPS72-0PT5ESK ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT5ESK

CPS72-0PT2GSA

© E+H ORP-comb.-electrode CPS72-0PT2GSA

Endress + Hauser CPS72-0PT2GSA ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT2GSA

CPS72-0PT5ESC

© E+H ORP-comb.-electrode CPS72-0PT5ESC

Endress + Hauser CPS72-0PT5ESC ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT5ESC

CPS72-0PT5ESA

© E+H ORP-comb.-electrode CPS72-0PT5ESA

Endress + Hauser CPS72-0PT5ESA ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT5ESA

CPS72-0PT4ESA

© E+H ORP-comb.-electrode CPS72-0PT4ESA

Endress + Hauser CPS72-0PT4ESA ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT4ESA

CPS72-0PT2ESA

© E+H ORP-comb.-electrode CPS72-0PT2ESA

Endress + Hauser CPS72-0PT2ESA ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT2ESA

CPS72-0PT5GSA

Endress + Hauser CPS72-0PT5GSA ORP-comb.-electrode Diaphragm: Ceramic Reference system: Gel(non acrylamide) Double chamber or ion trap Working limit: max. 10 bar Endress Hauser CPS 72 0 Electrode Type: Basic version PT Measuring Surface: Platinum, -15...135oC, ion trap, 1 … [Read more...] about CPS72-0PT5GSA

Primary Sidebar

Contact us:





    E+H Analytics

    • Orbisint Sensors / Electrodes
    • Condumax
    • DIPFIT
    • Indumax
    • Liquiline
    • Liquisys
    • Orbipac sensors
    • Oxymax
    • Smartec

    E+H Level measurement

    • Levelflex
    • Liquicap
    • Liquiphant
    • Liquipoint
    • Minicap
    • Micropilot
    • Soliphant

    E+H Flow measurement

    • Flowphant
    • Picomag DMA
    • Promag 10
      • Promag 10D
    • Promag 50
    • Promag 53
    • Promag 200
    • Promag300

    E+H Pressure measurement

    • Cerabar
    • Ceraphant
    • Deltabar
    • Deltapilot

    More products

    • CUS50D-GR2BA7A1
    • CUS51D-AAC1B4
    • CUS50D-GR2AB3A1
    • CUS51D-AAC1A4
    • CUS50D-AA2AA7A1
    • CUS51D-AAD1A7
    • CUS50D-GR2BB3A1
    • CUS51D-AAC1B3+IA
    • CUS50D-AA2BB4A1+RARB
    • CUS51D-AAD1A7+IA
    • CUS50D-GR2AB4A1+RARB
    • CUS51D-GRC1B3
    • CUS50D-GR2AA4A1+RB
    • CUS50D-GR2AB4B1
    • CUS50D-GR2AA3B1
    • CUS51D-AAC1A7+IA
    • CUS51D-AAC1B3
    • CUS50D-AA2AA7B1
    • CUS50D-GR2AA8B1+RARBZ1
    • CUS51D-AAD1A8

    Footer

    • Contacts
    • Imprint
    • General Data Protection Regulation (GDPR) – Datenschutz
    • Conditions of Use
    • Copyright
    • Privacy Notice

    Search

    © 2023 · Bromberg, Staudt & Co.
    All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.