Endress + Hauser CPS11D-7FA4V pH comb. electrode Memosens functionality Diaphragm: PTFE Signal transmission: Digital Reference system: Gel Application: Standard process Conductivity: min 50uS/cm Temperature sensor integrated Endress Hauser CPS 11D 7 Version: Basic version … [Read more...] about CPS11D-7FA4V
ENDRESS + HAUSER Digital pH sensors Orbisint CPS11D / CPS11 Glass pH comb. electrode
Digital pH sensor Orbisint CPS11D / CPS11
Glass pH comb. electrode Memosens functionality
Reference system: Gel
Conductivity: min 50uS/cm
pH electrodes CPS11 / CPS11D application:
– Chemical industry: strong acids/bases, plastic, pulp and paper industry
– Power plants (e.g. flue gas cleaning), oil and gas
– Incinerator plants
Water/wastewater treatment
– Boiler feedwater and cooling water
– Well water and drinking water
– All industrial and municipal treatment plants
With ATEX, IECEx, FM, CSA, TIIS and NEPSI approval for use in hazardous areas
pH electrodes CPS11 / CPS11D advantages are:
- - Low-maintenance and robust thanks to large PTFE ring junction
- - Can be used at pressures up to 17 bar abs. (246 psi)
- - Process glass also for very alkaline applications (BA and BT versions)
- - Process glass for applications in media containing hydrofluoric acid (FA version)
- - For media with low conductivity (AS version)
- - Integrated NTC30K temperature sensor (Memosens) for effective temperature compensation; Pt100 or Pt1000 for analog sensors
- - Optional: Poison-resistant reference with ion trap
pH electrodes CPS11 / CPS11D measured values:
- - pH value
- -Temperature
Available CPS11 / CPS11D measuring ranges:
- - Electrode version AA (for water / wastewater), AS (for boiler feedwater):
pH: 1 to 12
Temperature: -15 to 80 °C (5 to 176 °F) - - Electrode version BA (for process):
pH: 0 to 14
Temperature: 0 to 135 °C (32 to 275 °F) - - Electrode version FA (for hydrofluoric acid process):
pH: 0 to 10
Temperature: 0 to 70 °C (32 to 158 °F) - Electrode version BT with ion trap (for chemicals, scrubbers, pulp and paper):
pH: 0 to 14
Temperature: 0 to 135 °C (32 to 275 °F)
CPS11D-7AA2V
Endress + Hauser CPS11D-7AA2V pH comb. electrode Memosens functionality Diaphragm: PTFE Signal transmission: Digital Reference system: Gel Application: Standard process Conductivity: min 50uS/cm Temperature sensor integrated Endress Hauser CPS 11D 7 Version: Basic version … [Read more...] about CPS11D-7AA2V
CPS11D-7FA4C
Endress + Hauser CPS11D-7FA4C pH comb. electrode Memosens functionality Diaphragm: PTFE Signal transmission: Digital Reference system: Gel Application: Standard process Conductivity: min 50uS/cm Temperature sensor integrated Endress Hauser CPS 11D 7 Version: Basic version … [Read more...] about CPS11D-7FA4C
CPS11D-7AS2C
Endress + Hauser CPS11D-7AS2C pH comb. electrode Memosens functionality Diaphragm: PTFE Signal transmission: Digital Reference system: Gel Application: Standard process Conductivity: min 50uS/cm Temperature sensor integrated Endress Hauser CPS 11D 7 Version: Basic version … [Read more...] about CPS11D-7AS2C
CPS11D-7AA4C
Endress + Hauser CPS11D-7AA4C pH comb. electrode Memosens functionality Diaphragm: PTFE Signal transmission: Digital Reference system: Gel Application: Standard process Conductivity: min 50uS/cm Temperature sensor integrated Endress Hauser CPS 11D 7 Version: Basic version … [Read more...] about CPS11D-7AA4C
CPS11D-7AA2C
Endress + Hauser CPS11D-7AA2C Memosens functionality Diaphragm: PTFE Signal transmission: Digital Reference system: Gel Application: Standard process Conductivity: min 50uS/cm Temperature sensor integrated Endress Hauser CPS 11D 7 Version: Basic version AA Application Range: … [Read more...] about CPS11D-7AA2C
E+H CPS11-2FA5ESC
Endress + Hauser CPS11-2FA5ESC Endress + Hauser pH comb. electrode Diaphragm: PTFE Reference system: Gel Application: Standard process. Conductivity: min 50uS/cm Working limit: refer to TI Endress + Hauser CPS11 2 Electrode Type: Zero point Eo=7.0 + Pt100 FA Application Range: … [Read more...] about E+H CPS11-2FA5ESC
E+H CPS11-2FA6ESK
Endress + Hauser CPS11-2FA6ESK pH comb. electrode CPS11 Diaphragm: PTFE Reference system: Gel Application: Standard process. Conductivity: min 50uS/cm Working limit: refer to TI Endress + Hauser CPS11 2 Electrode Type: Zero point Eo=7.0 + Pt100 FA Application Range: 0-10pH, … [Read more...] about E+H CPS11-2FA6ESK
E+H CPS11-2BT5ESA
Endress + Hauser CPS11-2BT5ESA pH comb. electrode CPS11 Diaphragm: PTFE Reference system: Gel Application: Standard process. Conductivity: min 50uS/cm Working limit: refer to TI Endress + Hauser CPS11 2 Electrode Type: Zero point Eo=7.0 + Pt100 BT Application Range: 0-14pH, … [Read more...] about E+H CPS11-2BT5ESA
E+H CPS11-2BA5ESK
Endress + Hauser CPS11-2BA5ESK pH comb. Endress + Hauser electrode Diaphragm: PTFE Reference system: Gel Application: Standard process. Conductivity: min 50uS/cm Working limit: refer to TI Endress + Hauser CPS11 2 Electrode Type: Zero point Eo=7.0 + Pt100 BA Application Range: … [Read more...] about E+H CPS11-2BA5ESK
E+H CPS11-2AS4ESK
Endress + Hauser CPS11-2AS4ESK pH electrodes Diaphragm: PTFE Reference system: Gel Application: Standard process. Conductivity: min 50uS/cm Working limit: refer to TI Endress + Hauser CPS11 2 Electrode Type: Zero point Eo=7.0 + Pt100 AS Application Range: 1-12pH, -15...80oC, 6 … [Read more...] about E+H CPS11-2AS4ESK
E+H CPS11-2AA4ESC
Endress + Hauser CPS11-2AA4ESC pH comb. electrode Diaphragm: PTFE Reference system: Gel Application: Standard process Conductivity: min 50uS/cm Working limit: refer to TI Endress + Hauser CPS11 2 Electrode Type: Zero point Eo=7.0 + Pt100 AA Application Range: 1-12pH,-15...80oC, … [Read more...] about E+H CPS11-2AA4ESC
E+H CPS11-1FA2GSA
Endress + Hauser CPS11-1FA2GSA pH comb. electrode Diaphragm: PTFE Reference system: Gel Application: Standard process. Conductivity: min 50uS/cm Working limit: refer to TI Endress + Hauser CPS11 1 Electrode Type: Zero point Eo=7.0 FA Application Range: 0-10pH, 0...70oC; 6 bar; … [Read more...] about E+H CPS11-1FA2GSA
E+H CPS11D-7FA61
Endress + Hauser CPS11D-7FA61 pH comb. electrode Memosens functionality Diaphragm: PTFE Signal transmission: Digital Reference system: Gel Application: Standard process Conductivity: min 50uS/cm Temperature sensor integrated Endress + Hauser CPS11D 7 Version: Basic version … [Read more...] about E+H CPS11D-7FA61
E+H CPS11D-7AA5K
Endress + Hauser CPS11D-7AA5K pH comb. electrode Memosens functionality Diaphragm: PTFE Signal transmission: Digital Reference system: Gel Application: Standard process Conductivity: min 50uS/cm Temperature sensor integrated Endress + Hauser CPS11D 7 Version: Basic version … [Read more...] about E+H CPS11D-7AA5K
E+H CPS11-1FA6ESK
Endress + Hauser CPS11-1FA6ESK pH comb. electrode Diaphragm: PTFE Reference system: Gel Application: Standard process. Conductivity: min 50uS/cm Working limit: refer to TI Endress + Hauser CPS11 1 Electrode Type: Zero point Eo=7.0 FA Application Range: 0-10pH, 0...70oC; 6 bar; … [Read more...] about E+H CPS11-1FA6ESK
E+H CPS11-1BA6ESK
Endress + Hauser CPS11-1BA6ESK pH comb. electrode Diaphragm: PTFE Reference system: Gel Application: Standard process. Conductivity: min 50uS/cm Working limit: refer to TI Endress + Hauser CPS11 1 Electrode Type: Zero point Eo=7.0 BA Application Range: 0-14pH, 0...135oC; 16 bar; … [Read more...] about E+H CPS11-1BA6ESK
E+H CPS11D-7BT6V
Endress + Hauser CPS11D-7BT6V pH comb. electrode Memosens functionality Diaphragm: PTFE Signal transmission: Digital Reference system: Gel Application: Standard process Conductivity: min 50uS/cm Temperature sensor integrated Endress + Hauser CPS11D 7 Version: Basic version … [Read more...] about E+H CPS11D-7BT6V
E+H CPS11D-7AA4C
Endress + Hauser CPS11D-7AA4C pH comb. electrode Memosens functionality Diaphragm: PTFE Signal transmission: Digital Reference system: Gel Application: Standard process Conductivity: min 50uS/cm Temperature sensor integrated Endress + Hauser CPS11D- 7 Version: Basic version … [Read more...] about E+H CPS11D-7AA4C
E+H CPS11-1AT2GSA
Endress + Hauser CPS11-1AT2GSA pH comb. electrode Diaphragm: PTFE Reference system: Gel Application: Standard process. Conductivity: min 50uS/cm Working limit: refer to TI Endress + Hauser CPS11 1 Electrode Type: Zero point Eo=7.0 AT Application Range: 0-12pH, -15-80oC, 6 … [Read more...] about E+H CPS11-1AT2GSA
E+H CPS11D-8BA5G
Endress + Hauser CPS11D-8BA5G pH comb. electrode Memosens functionality Diaphragm: PTFE Signal transmission: Digital Reference system: Gel Application: Standard process Conductivity: min 50uS/cm Temperature sensor integrated Endress + Hauser CPS11D 8 Version: SIL … [Read more...] about E+H CPS11D-8BA5G
E+H CPS11-1AS4ESC
Endress + Hauser CPS11-1AS4ESC pH comb. electrode Diaphragm: PTFE Reference system: Gel Application: Standard process. Conductivity: min 50uS/cm Working limit: refer to TI Endress + Hauser CPS11 1 Electrode Type: Zero point Eo=7.0 AS Application Range: 1-12pH, -15...80oC, 6 bar, … [Read more...] about E+H CPS11-1AS4ESC
E+H CPS11-1FA5GSA
Endress + Hauser CPS11-1FA5GSA pH comb. electrode Diaphragm: PTFE Reference system: Gel Application: Standard process. Conductivity: min 50uS/cm Working limit: refer to TI Endress + Hauser CPS11 1 Electrode Type: Zero point Eo=7.0 FA Application Range: 0-10pH, 0...70oC; 6 bar; … [Read more...] about E+H CPS11-1FA5GSA
E+H CPS11D-7AA2C
Endress + Hauser CPS11D-7AA2C pH comb. electrode Memosens functionality Diaphragm: PTFE Signal transmission: Digital. Reference system: Gel. Application: Standard process. Conductivity: min 50uS/cm Temperature sensor integrated Endress + Hauser CPS11D 7 Version: Basic version … [Read more...] about E+H CPS11D-7AA2C
E+H CPS11D-7BT4C
Endress + Hauser CPS11D-7BT4C pH comb. electrode Memosens functionality Diaphragm: PTFE Signal transmission: Digital Reference system: Gel. Application: Standard process. Conductivity: min 50uS/cm Temperature sensor integrated Endress + Hauser CPS11D 7 Version: Basic version … [Read more...] about E+H CPS11D-7BT4C
E+H CPS11-1AA2ESA
Endress + Hauser CPS11-1AA2ESA pH comb. electrode Diaphragm: PTFE Reference system: Gel Application: Standard process. Conductivity: min 50uS/cm Working limit: refer to TI Endress + Hauser CPS11 1 Electrode Type: Zero point Eo=7.0 AA Application Range: 1-12pH,-15...80oC, 6 bar … [Read more...] about E+H CPS11-1AA2ESA
E+H CPS11D-8BA4G
Endress + Hauser CPS11D-8BA4G pH comb. electrode Memosens functionality Diaphragm: PTFE Signal transmission: Digital. Reference system: Gel. Application: Standard process. Conductivity: min 50uS/cm Temperature sensor integrated Endress + Hauser CPS11D 8 Version: SIL … [Read more...] about E+H CPS11D-8BA4G
E+H CPS11D-8BA2G
Endress + Hauser CPS11D-8BA2G pH comb. electrode Memosens functionality Diaphragm: PTFE Signal transmission: Digital. Reference system: Gel. Application: Standard process. Conductivity: min 50uS/cm Temperature sensor integrated Endress + Hauser CPS11D 8 Version: SIL … [Read more...] about E+H CPS11D-8BA2G
E+H CPS11D-7BA41 Orbisint CPS11D Memosens
Endress + Hauser CPS11D-7BA41 Orbisint CPS11D Memosens electrode CPS11D 7 Version: Basic version BA Application Range: 0-14pH, 0...135oC, 16 bar, sterilizable 4 Shaft Length: 225mm 1 Approval: Non-hazardous area … [Read more...] about E+H CPS11D-7BA41 Orbisint CPS11D Memosens
E+H CPS11D-7BA2G Orbisint CPS11D electrode
Endress + Hauser CPS11D-7BA2G Orbisint CPS11D Memosens electrode CPS11D 7 Version: Basic version BA Application Range: 0-14pH, 0...135oC, 16 bar, sterilizable 2 Shaft Length: 120mm G Approval: ATEX/NEPSI II 1G; FM IS NI; CSA IS NI Ex ia IIC T3/T4/T6 Ga ; CL.I. Div 1,Group A-D IECEx EX … [Read more...] about E+H CPS11D-7BA2G Orbisint CPS11D electrode