Endress + Hauser NMS83-NC2BE1X0X0AC2EC24AED1GSJNTC
Level/Interface/Density profile, Servo
Precision device, hygienic
Application: liquids
Liquid foods, beverages, alcohols
Highly precise measurement for
custody transfer and inventory control
Superior corrosion resistance
Hybrid tank measurement system
Tank correction algorithms
Flexible fieldbuses, inputs and outputs
Complete tank sensor integration
:: Cleaning-in-place
:: 316L materials
:: SIL2 / SIL3 according IEC61508
:: Level, interface, density profile
NMS83-1T10/0
Endress Hauser NMS 83
NC Approval: NEPSI Ex d[ia] IIC T6 Ga/Gb
2 Terminal Type: Screw terminals
B Power Supply; Display: 85-264VAC; LCD + operation
E1 Primary Output: 4-20mA HART Ex d/XP, RTD input
X0 Secondary I/O Analogue: Not selected
X0 Secondary I/O Digital Ex d/XP: Not selected
AC Housing: Transmitter Alu, coated, process 316/316L
2 Process Pressure: 0…6bar/600kPa/87psi
E Electrical Connection: Thread NPT1/2, IP66/68 NEMA Type 4X/6P Encl.
C2 Measuring Range; Wire; Diameter: 22m; AlloyC276; 0.2mm
4AE Displacer Material; Type: 316L polished; 70mm conical
D1 Process Sealing: PTFE -100…200oC/-148…392oF, wire drum FKM -40…200oC/-40…392oF
GSJ Process Connection: DN80 PN10/16 B1, 316L flange EN1092-1
NTC Accuracy, Weight + Measure Approval: Custody transfer, NMi type approval acc. to OIML R85, API 3.1B, ISO4266, factory calib. certificate