Endress + Hauser FMR50-AACCAABMGGF
Radar, level, contactless
Basic device
Application: liquids
Integrated data memory
:: High availability.
:: Reliable measuring:
for changing medias, pressure,
temperatures, gas phases
FMR50-2J80/0
Endress Hauser FMR 50
AA Approval: Non-hazardous area
C Power Supply; Output: 2-wire; 4-20mA HART + 4-20mA analog
C Display, Operation: SD02 4-line, push buttons + data backup function
A Housing: GT19 Dual compartment, plastic PBT
A Electrical Connection: Gland M20, IP66/68 NEMA4X/6P
BM Antenna: Horn 40mm/1-1/2”, PVDF encapsulated, -40…130oC/-40…266oF
GGF Process Connection: Thread ISO228 G1-1/2, PVDF