Endress + Hauser COM223-WS2110 Transmitter, dissolved oxygen DO Panel mounting: 96x96mm, front IP54 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress + Hauser COM 223 WS Sensor Input; Software: COS31/COS61/COS71 (COS3/3HD), plus package 2 Power … [Read more...] about COM223-WS2110
Endress + Hauser Analytics
Endress + Hauser CA72TOC -TOC analyzer
TURBIMAX CUS SENSORS FOR TURBIDITY MEASUREMENT
Process analytical technology pharmaceutical industry
CLS16D-3C1UG
Endress + Hauser CLS16D-3C1UG Conductivity, 2-electrode sensor Memosens functionality hygienic design, EHEDG Life Science, Water (Utilities) * Ultrapure / Pure Water * Water for Injection (WFI) * Water Measurement range 0,04 - 500 uS/cm Stainless steel 1.4435 (316L), FFKM FDA, … [Read more...] about CLS16D-3C1UG
CPS491-2ESC2
Endress + Hauser CPS491-2ESC2 pH-comb. electrode, ISFET-Technology Diaphragm: open aperture Reference: Gel Temp. sensor: Pt1000 Material: PEEK Working limit: max 10 bar CPS491-1077/0 Endress Hauser CPS 491 2 Shaft Length: 120mm ESC Head: Process Pg13.5;SteckerTOP68, EAC nonEx … [Read more...] about CPS491-2ESC2
CPS71-3TP2ESA
Endress + Hauser CPS71-3TP2ESA pH-comb. electrode Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber or ion trap Application: Hygienic, sterile process Sterilizable; autoclavable Conductivity: min 10uS/cm Endress Hauser CPS 71 3 Electrode Type: Zero point … [Read more...] about CPS71-3TP2ESA
CM42-MIA511EHE00
Endress + Hauser CM42-MIA511EHE00 Transmitter liquid analysis Multiparameter, loop-powered Worldwide approvals, hazardous areas developed according to IEC 61508, pH/ORP, conductivity,oxygen (DO) digital sensors, Memosens protocol or analog sensors Field housing+panel mounting … [Read more...] about CM42-MIA511EHE00
CLM223-CD1605
Endress + Hauser CLM223-CD1605 Transmitter, conductivity Panel mounting: 96x96mm, front IP54 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CLM 223 CD Sensor Input; Software: Conductive sensor; basic version 1 Power Supply: 115VAC … [Read more...] about CLM223-CD1605
CCM223-ES0310
Endress + Hauser CCM223-ES0310 Transmitter, chlorine/chlorine dioxide Panel mounting: 96x96mm, front IP54 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CCM 223 ES Sensor Input; Software: Cl2/ClO2; plus package 0 Power Supply: 230VAC … [Read more...] about CCM223-ES0310
CLS16D-4D1UG
Endress + Hauser CLS16D-4D1UG Conductivity, 2-electrode sensor Memosens functionality hygienic design, EHEDG Life Science, Water (Utilities) * Ultrapure / Pure Water * Water for Injection (WFI) * Water Measurement range 0,04 - 500 uS/cm Stainless steel 1.4435 (316L), FFKM FDA, … [Read more...] about CLS16D-4D1UG
OUSAF44-B1A0
Endress + Hauser OUSAF44-B1A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 B Wavelength: 280 nm 1 Calibration/Validation: Easycal A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-B1A0
CPS471D-741G+Z1
Endress + Hauser CPS471D-741G+Z1 pH-comb. electrode, ISFET-Technology Memosens functionality Signal transmission: Digital Diaphragm: Ceramic Reference system: Gel (non acrylamide) Double chamber Temp.-sensor: Pt1000 Material: PEEK Working limit: max.10 bar CPS471D-1566/0 Endress … [Read more...] about CPS471D-741G+Z1
COM253-WS7526
Endress + Hauser COM253-WS7526 Transmitter, dissolved oxygen DO Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser COM 253 WS Sensor Input; Software: COS31/COS61/COS71 (COS3/3HD) plus package 7 Power Supply: … [Read more...] about COM253-WS7526
OUSAF44-F0B0
Endress + Hauser OUSAF44-F0B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 F Wavelength: 365 nm 0 Calibration/Validation: Standard B Lamp Approval: FM XP Cl. I Div. … [Read more...] about OUSAF44-F0B0
CPS47D-AA8OCO5+JF
Endress + Hauser CPS47D-AA8OCO5+JF pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramik, Reference: KCl liquid CPS47D-11A5/0 Endress Hauser CPS 47D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 O Application … [Read more...] about CPS47D-AA8OCO5+JF
OUSAF12-A0D0A
Endress + Hauser OUSAF12-A0D0A Color and NIR absorbance sensor, wavelength range 400-1500 nm Measuring range: up to 50 OD (depending on OPL) Light source: Low wattage incandescent lamp Endress Hauser OUSAF 12 A Wavelength: 400 nm 0 Calibration/validation: Standard D Lamp: Gas … [Read more...] about OUSAF12-A0D0A
OUSAF44-C1C0
Endress + Hauser OUSAF44-C1C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 C Wavelength: 295 nm 1 Calibration/Validation: Easycal C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-C1C0
CLS15D-B1AV
Endress + Hauser CLS15D-B1AV Conductivity 2 electrode sensor Memosens functionality Signal transmission: digital Materials: 316L; PES Endress Hauser CLS 15D B Measuring Range; Cell Constant: 0.1-200uS/cm; k=0.1 1A Process Connection: thread NPT 1/2”; PES V Approval: ATEX / NEPSI … [Read more...] about CLS15D-B1AV
CLS15D-A1AV
Endress + Hauser CLS15D-A1AV Conductivity 2 electrode sensor Memosens functionality Signal transmission: digital Materials: 316L; PES Endress Hauser CLS 15D A Measuring Range; Cell Constant: 0.04-20uS/cm; k=0.01 1A Process Connection: thread NPT 1/2”; PES V Approval: ATEX / … [Read more...] about CLS15D-A1AV
OUSAF44-E0B0
Endress + Hauser OUSAF44-E0B0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 E Wavelength: 313 nm 0 Calibration/Validation: Standard B Lamp Approval: FM XP Cl. I Div. … [Read more...] about OUSAF44-E0B0
OUSAF44-A0C0
Endress + Hauser OUSAF44-A0C0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 A Wavelength: 254 nm 0 Calibration/Validation: Standard C Lamp Approval: ATEX II 2G Ex db … [Read more...] about OUSAF44-A0C0
OUSAF44-B0A0
Endress + Hauser OUSAF44-B0A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 B Wavelength: 280 nm 0 Calibration/Validation: Standard A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-B0A0
OUA260-BA1C04C4B3A
Endress + Hauser OUA260-BA1C04C4B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A1 Process Connection: Triclover 316L C Mean diameter: 0.5” 04 Optical Pathlength (OPL): 2 mm Standard C Window … [Read more...] about OUA260-BA1C04C4B3A
CCM253-ES0310
Endress + Hauser CCM253-ES0310 Transmitter, chlorine/chlorine dioxide Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser CCM 253 ES Sensor Input; Software: Cl2/ClO2; plus package 0 Power Supply: 230VAC … [Read more...] about CCM253-ES0310
OUSAF44-E1A0
Endress + Hauser OUSAF44-E1A0 UV absorbance sensor for Wavelength range 254-365 nm Measuring range. UP TO 50OD (dep on OPL) Light source: low pressure mercury lamp Endress Hauser OUSAF 44 E Wavelength: 313 nm 1 Calibration/Validation: Easycal A Lamp Approval: Non-hazardous … [Read more...] about OUSAF44-E1A0
OUSAF12-A1D0A
Endress + Hauser OUSAF12-A1D0A Color and NIR absorbance sensor, wavelength range 400-1500 nm Measuring range: up to 50 OD (depending on OPL) Light source: Low wattage incandescent lamp Endress Hauser OUSAF 12 A Wavelength: 400 nm 1 Calibration/validation: Easycal (1 filter) … [Read more...] about OUSAF12-A1D0A
OUA260-BA2C05C4B3B
Endress + Hauser OUA260-BA2C05C4B3B Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 A2 Process Connection: Triclover Kynar, non ex C Mean diameter: 0.5” 05 Optical Pathlength (OPL): 2 mm with POPL … [Read more...] about OUA260-BA2C05C4B3B
COM253-DS7410
Endress + Hauser COM253-DS7410 Transmitter, dissolved oxygen DO Field mounting: 247x170x115mm, IP65 Alarm output: relay Display: 2-line, 6 languages Calibration: CAL button Endress Hauser COM 253 DS Sensor Input; Software: COS41 (COS4/4HD); plus package 7 Power Supply: 24V AC/DC; … [Read more...] about COM253-DS7410
CPS41-3BC2ESC
Endress + Hauser CPS41-3BC2ESC pH-comb. electrode Diaphragm: Ceramic Reference: liquid, hose connection Working limit: max 10 bar Endress Hauser CPS 41 3 Electrode Type: Zero point Eo=7,0; with PT1000 sensor BC Application Range: 0-14pH, 0-130oC,3Diaphr.steril. 2 Shaft Length: … [Read more...] about CPS41-3BC2ESC
OUSAF11-AA110B2A10A
Endress + Hauser OUSAF11-AA110B2A10A Glass-free absorbance sensor Wavelength range: 390-1100 nm. Measuring range: 0-2,5 AU;(up to 0-5 OD) Light source: Low wattage incandescent lamp OUSAF11-2FL5/0 Endress Hauser OUSAF 11 AA Approval: Non-hazardous area 1 Wavelength: NIR, … [Read more...] about OUSAF11-AA110B2A10A
CPS77D-AA8OHU4+JF
Endress + Hauser CPS77D-AA8OHU4+JF pH-comb. electrode, ISFET-Technology, Memosens, Diaphragm: Ceramic, Reference: Gel CPS77D-10A1/0 Endress Hauser CPS 77D AA Approval: Non-hazardous area 8 Electrode Type: Operational point = 0 mV, temperature sensor Pt1000 O Application Range: … [Read more...] about CPS77D-AA8OHU4+JF
OUA260-BF1B03B2B3A
Endress + Hauser OUA260-BF1B03B2B3A Flow through assembly for process photometer, OUSAFxx and OUSTFxx Endress Hauser OUA 260 B Sensor type: for OUSAF12/OUSAF22 F1 Process Connection: Tube Stub B Mean diameter: 0.375” 03 Optical Pathlength (OPL): 1 mm with POPL B Window … [Read more...] about OUA260-BF1B03B2B3A