• Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Bromberg, Staudt & Co. GmbH

  • Home
  • About us
  • Our services
  • Industries
  • Brands
    • Endress+Hauser
  • Contacts
  • EnglishEnglish
    • EspañolEspañol
    • TagalogTagalog
    • 한국어한국어
    • 中文 (中国)中文 (中国)
    • DeutschDeutsch
Home / Endress+Hauser / E+H Analytics / Oxymax / COS41

Endress + Hauser COS41 Dissolved oxygen sensor Oxymax for water, wastewater and utilities

Endress + Hauser COS41 Dissolved oxygen sensor E+H

Endress + Hauser Oxymax COS41 is a reliable and accurate oxygen sensor for all kinds of water & wastewater applications. Extreme stable membrane- Analog communication

E+H COS41 Dissolved oxygen sensor measured value

  • dissolved oxygen [mg/l, ppm, % SAT or hPa]

COS41 Dissolved oxygen sensor measuring range

with Liquisys M COM 223/253-DX/DS:
0.05 ... 20.00 mg/l (ppm)
0.00 ... 200 % SAT
0 ... 400 hPa

COS41 Dissolved oxygen sensor application

Oxymax COS41 measures the dissolved oxygen concentration in:
Wastewater treatment plants:
- O2 control in the aeration basin
- Process water treatment and monitoring
Water works:
- Status monitoring of drinking water (oxygen enrichment, corrosion protection, etc.)
- Water quality monitoring in rivers, lakes or seas
Utilities of all industries:
- O2 control in the biological treatment
- Process water treatment and monitoring
Fish farming:
- O2 control for optimum growth conditions

COS41 Dissolved oxygen sensor advantages are

• High measurement accuracy
• Long maintenance intervals
• Minimum calibration effort thanks to simple air calibration

COS41 Dissolved oxygen sensor process temperature

–5 to 50 °C (20 to 120 °F)

COS41 Dissolved oxygen sensor process pressure

max. 10 bar (145 psi) permissible overpressure - Underpressure operation is not permissible.

COS41-8S

© E+H Dissolved oxygen sensor COS41-8S

Endress + Hauser COS41-8S Dissolved oxygen sensor, amperometric 2 electrode cell Application: Water, waste water Measuring range: 0.05...20 mg/l :: Compatibility, Sensor: COS4 Endress Hauser COS 41 8 Cable Length: w/o cable S Head: Thread G1, NPT3/4; plug TOP68 … [Read more...] about COS41-8S

COS41-2S

© E+H Dissolved oxygen sensor COS41-2S

Endress + Hauser COS41-2S Dissolved oxygen sensor, amperometric 2 electrode cell Application: Water, waste water Measuring range: 0.05...20 mg/l :: Compatibility, Sensor: COS4 Endress Hauser COS 41 2 Cable Length: 7m S Head: Thread G1, NPT3/4; plug TOP68 … [Read more...] about COS41-2S

COS41-4F

© E+H Dissolved oxygen sensor COS41-4F

Endress + Hauser COS41-4F Dissolved oxygen sensor, amperometric 2 electrode cell Application: Water, waste water Measuring range: 0.05...20 mg/l :: Compatibility, Sensor: COS4 Endress Hauser COS 41 4 Cable Length: 15m F Head: Thread G1, NPT3/4; fixed cable … [Read more...] about COS41-4F

COS41-2F

© E+H Dissolved oxygen sensor COS41-2F

Endress + Hauser COS41-2F Dissolved oxygen sensor, amperometric 2 electrode cell Application: Water, waste water Measuring range: 0.05...20 mg/l :: Compatibility, Sensor: COS4 Endress Hauser COS 41 2 Cable Length: 7m F Head: Thread G1, NPT3/4; fixed cable … [Read more...] about COS41-2F

COS41-4S

© E+H Dissolved oxygen sensor COS41-4S

Endress + Hauser COS41-4S Dissolved oxygen sensor, amperometric 2 electrode cell Application: Water, waste water Measuring range: 0.05...20 mg/l :: Compatibility, Sensor: COS4 Endress + Hauser COS41 4 Cable Length: 15m S Head: Thread G1, NPT3/4; plug TOP68 … [Read more...] about COS41-4S

Primary Sidebar

Contact us:





E+H Analytics

  • Orbisint Sensors / Electrodes
  • Condumax
  • DIPFIT
  • Indumax
  • Liquiline
  • Liquisys
  • Orbipac sensors
  • Oxymax
  • Smartec

E+H Level measurement

  • Levelflex
  • Liquicap
  • Liquiphant
  • Liquipoint
  • Minicap
  • Micropilot
  • Soliphant

E+H Flow measurement

  • Flowphant
  • Picomag DMA
  • Promag 10
    • Promag 10D
  • Promag 50
  • Promag 53
  • Promag 200
  • Promag300

E+H Pressure measurement

  • Cerabar
  • Ceraphant
  • Deltabar
  • Deltapilot

More products

  • NMR81-NE2BE1X0A1ACAABA1GWJICX
  • FMR67-GRAAAAGPA6AGJ1
  • FMR533-DAC6JAC3GA
  • NMR81-GR2BE1X0A1ACAABA1GQJICR
  • NMR84-GC2BE1X0A1ACABDA1G5JICR
  • FMR540-6E1CQJAC2FA
  • CA80AM-GRA11C101
  • FMR67-CAAACBGPA6AGJ1
  • FMR533-1ACWJAC3GA
  • NMR81-NE1BA1X0A1ACAABA1GSJICR
  • NMR84-BC2BA1X0A1ACABDA1G5JICR
  • FMR540-6H1CKJAC2AA
  • FMR60-B2BCCDGAA4XKJ
  • FMR67-BHAAAAGPA6AGJ1
  • FMR533-6AC6JAC4FA
  • NMR84-IC2BB1X0A1ACABDA1G5JICR
  • FMR540-SE2CQJAC2FA
  • NMR81-IC2BB1X0A1ACAABA1GUJICR
  • FMR57-AAKABDBCA6CHJ1
  • FMR60-CABAAAGAA4RGJ

Footer

  • Contacts
  • Imprint
  • General Data Protection Regulation (GDPR) – Datenschutz
  • Conditions of Use
  • Copyright
  • Privacy Notice

Search

© 2019 · Bromberg, Staudt & Co.
All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.